• Title/Summary/Keyword: Contouring

Search Result 235, Processing Time 0.027 seconds

An Integrated Approach to the Analysis and Design of a Three-Axis Cross-Coupling Control System

  • Jee, Sung-Chul;Lee, Hak-Chul
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.59-63
    • /
    • 2007
  • We propose a controller design analysis for a cross-coupling control system, which is essential for achieving high contouring accuracy in multi-axis CNC systems. The proposed analysis combines three axial controllers for each individual feed drive system together with a cross-coupling controller at the beginning of the design stage in an integrated manner. These two types of controllers used to be separately designed and analyzed since they have different control objectives. The proposed scheme is based on a mathematical formulation of a three-dimensional contour error model and includes a stability analysis for the overall control system and a performance analysis in terms of contouring and tracking accuracy at steady state. A computer simulation was used to demonstrate the validity of the proposed methodology. The performance variation was investigated under different operating conditions and controller gains, and a design range was elicited that met the given performance specifications. The results provide basic guidelines in systematic and comprehensive controller designs for multi-axis CNC systems. A cross-coupling control system was also implemented on a PC-based three-axis CNC testbed, and the experimental results confirmed the usefulness of the proposed control system in terms of contouring accuracy.

Inferior alveolar nerve cutting; legal liability versus desired patient outcomes

  • Kim, Soung Min;Lee, Jong Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.5
    • /
    • pp.318-323
    • /
    • 2017
  • Objectives: Mandibular angle reduction or reduction genioplasty is a routine well-known facial contouring surgery that reduces the width of the lower face resulting in an oval shaped face. During the intraoral resection of the mandibular angle or chin using an oscillating saw, unexpected peripheral nerve damage including inferior alveolar nerve (IAN) damage could occur. This study analyzed cases of damaged IANs during facial contouring surgery, and asked what the basic standard of care in these medical litigation-involved cases should be. Materials and Methods: We retrospectively reviewed a total of 28 patients with IAN damage after mandibular contouring from August 2008 to July 2015. Most of the patients did not have an antipathy to medical staff because they wanted their faces to be ovoid shaped. We summarized three representative cases according to each patient's perceptions and different operation procedures under the approvement by the Institutional Review Board of Seoul National University. Results: Most of the patients did not want to receive any further operations not due to fear of an operation but because of the changes in their facial appearance. Thus, their fear may be due to a desire for a better perfect outcome, and to avoid unsolicited patient complaints related litigation. Conclusion: This article analyzed representative IAN cutting cases that occurred during mandibular contouring esthetic surgery and evaluated a questionnaire on the standard of care for the desired patient outcomes and the specialized surgeon's position with respect to legal liability.

Slimming of Lower Face by Contouring of the Mandibular Body in Orthognathic Surgery Patients

  • Park, Bong-Wook;Kang, Young-Hoon;Choi, Mun-Jeoung;Kim, Si-Yeob;Kang, Hea-Gea;Kim, Jong-Ryoul;Byun, June-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.325-330
    • /
    • 2013
  • The patient's appearance can be dramatically enhanced as a result of orthognathic surgery. However, esthetic contouring of the mandibular body portion is often overlooked in the surgery. Restoring a more beautiful jaw line is important and directly affects surgical results. From December 2010 to February 2012, we performed mandibular body contouring for the slimming of the third lower part of the face in 37 patients who had undergone either 1-jaw surgery or 2-jaw surgery. The third lower part of the facial contour was improved in all the patients after at least 3 months follow-up. Mandibular body contouring is a simple method that can be additionally used for the slimming of the third lower part of the face in patients who require orthognathic surgeries. It makes the lower face look more attractive from both the anterior and lateral perspectives.

Upper Arm Contouring with Brachioplasty after Massive Weight Loss

  • Han, Hyun Ho;Lee, Min Cheol;Kim, Sang Hwa;Lee, Jung Ho;Ahn, Sang Tae;Rhie, Jong Won
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.271-276
    • /
    • 2014
  • Background As the obese population increases in Korea, the number of patients who are trying to lose weight has been increasing steadily. In these patients, skin laxity and deformation of the body contour occurs, which could possibly be corrected by various body contouring surgeries. Here, we introduce the brachioplasty method and our experience of various body contouring surgeries performed in our center. Methods From November 2009 to August 2011, five cases of brachioplasty were performed. When the patient presented with sagging of the lateral inframammary crease and bat wing deformity in the axilla, extended brachioplasty was performed; in this case, the deformation of the axilla and lateral chest was corrected at the same time. A traditional brachioplasty was performed when contouring was needed only for skin laxity in the upper arm. Results Complications, such as hematomas or nerve injuries, were not evident. Some patients experienced partial wound dehiscence due to tension or hypertrophic scars found during the follow-up. In general, all of the patients were satisfied with the improvement in their upper arm contour. Conclusions Given the demands for body contouring surgery, the number of brachioplasty surgical procedures is expected to increase significantly, with abdominoplasty comprising a large portion of these surgeries. For the brachioplasty procedure, preparation and preoperative consultation regarding design of the surgery by experienced surgeons was important to prevent complications such as nerve damage or hematoma formation.

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

Development of Software Interpolator for Two-Axis Contouring Control (2축 윤곽제어를 위한 소프트웨어 보간자 개발에 관한 연구)

  • 김교형;이기설
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.389-396
    • /
    • 1988
  • Microprocessor-based software DDA interpolator is developed and applied to two axis contouring control of X-Y table. Developed assembly program is composed of feedrate, linear and circular DDA interpolation routines. Reference-pulse type of open-loop stepping motor control system in which the micro-computer produces a sequence of reference pulses for each axis of motion is adopted. To test performance of the developed program, X-Y table drive system based on stepping motor and shaft encoder is designed. Conturing error of the system in linear and circular path is within .+-. 0.2mm under start stop pulse rate of stepping motor.

Study on Machining Precision in Ball End Mill Contouring Machining (볼엔드밀링 윤곽가공에서 가공 정밀도에 관한 연구)

  • Ryu Ho-Cheol;Choi Woo-Chun;Hong Dae-Hie
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.765-768
    • /
    • 2005
  • Ball end milling is widely used in machining free surfaces. It is important to predict machining forces in this machining. In this study, cutting forces are predicted for different machining conditions in ball end mill contouring machining. These cutting forces influence tool deflection. In this study tool deflection is calculated for various cutting conditions. The model developed in this study can be used to predict machining accuracy in contouring machining.

  • PDF

Surface contouring using Electronic Speckle Pattern Interferometry (전자 스페클 패턴 간섭계를 이용한 형상 측정)

  • 김계성;유원재;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.397-401
    • /
    • 1995
  • ESPI(Electronic Speckle Pattern Interfermetry) is an optical technique to measure surface deforamtion of engineering components and materials in industrial ares. This optical method is capable of providing full-field results with high spatial resolution, high speed and is the non-contact technique. One of important application aspects using electronic speckle pattern interferometry is to generate contours of a diffuse object in order to provide data for 3-D shape analysis and topography measurement. The contouring method by modified dual-beam speckle pattern interferometry is proposed. We introduce a shift of the illumination beams through optical fiber in order to obtain the contour fringe patterns. The speckle pattern correlation technique is suitable for providing measurement range from millimeters to several centimeters. The complete geometric analysis of the contoretical and experimental results are obtained.

  • PDF

Computation of Section Curves, Reflection Characteristic Lines, and Asymptotic Curves for Visualization (가시화를 위한 단면곡선, 반사성질선, 점근선 생성 기법)

  • 남종호
    • Korean Journal of Computational Design and Engineering
    • /
    • v.8 no.4
    • /
    • pp.262-269
    • /
    • 2003
  • An approach to compute characteristic curves such as section curves, reflection characteristic lines, and asymptotic curves on a surface is introduced. Each problem is formulated as a surface-plane inter-section problem. A single-valued function that represents the characteristics of a problem constructs a property surface on parametric space. Using a contouring algorithm, the property surface is intersected with a horizontal plane. The solution of the intersection yields a series of points which are mapped into object space to become characteristic curves. The approach proposed in this paper eliminates the use of traditional searching methods or non-linear differential equation solvers. Since the contouring algorithm has been known to be very robust and rapid, most of the problems are solved efficiently in realtime for the purpose of visualization. This approach can be extended to any geometric problem, if used with an appropriate formulation.

Cross-Coupling Controller for High-Speed Nonlinear Contour Machining (고속의 비선형 윤곽가공을 위한 교차축 연동제어기)

  • Jee, Sung-Chul;Lee, Yong-Seok
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.446-451
    • /
    • 2000
  • In this paper, a new adaptive cross-coupling control (CCC) algorithm with an improved contour error model is proposed to maintain contouring precision in high-speed nonlinear contour machining. The proposed method utilizes variable controller gains based on the instantaneous curvature of a contour and the feedrate command. The proposed method is evaluated and compared with the conventional CCC for nonlinear contouring motion through computer simulations. The simulation results show that the proposed CCC improves the contouring accuracy more effectively than the existing method.

  • PDF