• Title/Summary/Keyword: Continuous wall

Search Result 305, Processing Time 0.024 seconds

A Study of the Suppression System based on the Fire Protection System the Korea Cultural Property due to the Forest Fire -About Water Mist System- (산림화재로부터 문화재를 보호하는 소방시설에 관한 연구 -미분무수설비를 중심으로-)

  • Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.44-51
    • /
    • 2007
  • Most of the Korea temples of cultural property are wooden buildings and easy combusted. They are often located in mountain area far away from the city. It is very difficult to approach the fight area. The putting out is very difficult in the initial fire time. And for protecting the cultural property in the long-term continuous fire source there are some restrictions in water source and suppression system. In this paper the initial putting out fire due to the forest fire and the protection of cultural property in the long-term continuous fire source were researched. The improved project about fire control facilities of the Korea cultural property was proposed. In the proposed project the facilities using Water mist which can reduce more loss than existing facilities using water are applied. In view of the topographic position the method of eliminating the energy of combustibles and wall for cutting off the heat in the fire control facilities are also mentioned.

Effect of Reinforcement for Web Opening on Shear Strength of Reinforced Concrete Deep Beams (철근콘크리트 깊은 보의 전단 내력에 대한 개구부 보강 효과)

  • Lee, Jong-Kweon;Choi, Yun-Cheul;Lee, Yong-Taeg
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.699-708
    • /
    • 2007
  • Reinforced concrete deep beams are general structural members used as transfer-girder, pile cap, foundation wall and so on. They have a complex stess formation. Generally, failure mechanisms differ from either continuous deep beams or simple supported deep beams. In continuous deep beams, a negative moment is occurred over intermediate support and the location of maximum moment coincide with high shear force. Therefore, failure usually occurs at this region. While on the other hand, in simple supported deep beam, the region of high shear coincides with the region of low moment. The web opening of deep beams for accepting a facility makes shear behaviors of deep beams more complex and gives rise to an expansion of crack around the opening and a decline of shear capacity of deep beams. Therefore, Engineers must determine a delicate reinforcement method to control a crack and increase a shear capacity. The purpose of this report is a computation of an effective reinforcement method through non-linear finite element method by means of adopting various reinforcement method as variables and a computation of shear capacity formula taking an effectiveness of reinforcement into consideration.

Application of Open-source OpenFOAM for Simulating Combustion and Heating Performance in Horizontal CGL Furnace (수평형 CGL 소둔로의 연소 및 가열 성능 해석을 위한 오픈소스 OpenFOAM 기반 전산유체 해석)

  • Kim, GunHong;Oh, Kyung-Teak;Kang, Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.553-561
    • /
    • 2017
  • The main motivation for this study was to establish a CFD-based procedure for the analysis of heating characteristics, particularly in industrial furnaces. As certain open-source software packages have gained popularity in dealing with complex industrial problems, the OpenFOAM framework was selected for further development of advanced physical models to meet industrial requirements. In this study, the newly developed comprehensive model was applied to simulate physical processes in the full-scale horizontal furnace of a continuous galvanizing line (CGL). The numerical results obtained indicate that the current approach predicts heating characteristics reasonably well. It was also found that radiative heat transfer plays a dominant role in heating the moving strip. To improve the predictability of our method, further work is required to model the turbulence-chemistry interaction realistically, as well as to impose a physically correct thermal wall boundary condition.

Bioconversion of Pytogallo from Gallic Acid by Pseudomonas sp. KS-96 using Rotating Disc Contactor (회전원판 반응조를 이용한 Pseudomonas sp. KS-96에 의한 gallic acid로부터 Pyrogallol의 전환)

  • An, Seung-Man;Kim, Dong-Suck;Jeong, Young-Kee;Lim, Bock-Gu;Lee, Heung-Su;Ryu, Beung-Ho
    • Journal of Life Science
    • /
    • v.7 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • In previous paper Pseudomonas sp. Ks-96 isolated from the bioconversion into pyrogallol from gallic acid . Continuous bioconversion of pyrogallol was carried out using rotatory disc contactor immobilized Pseudomonas sp. Ks-96 . Enzyme activity of gallate decarboxylase released from Pseudomonas sp. Ks-96 were shown at the highest activity on 24h incubation. Culture media containing gallic acid supplied on the flow rate of 20m${\ell}$/h until thickness of cells wall reached steady state. Bioconversion rate of pyrogallol from gallic acid showed at highest level ranging from 18hr to 36h according to time courses. Continuous bioconversion of pyrogallol using rotating disc contactor was about 82% and 80% between 6 and 8 days at the feeding rate of 300m${\ell}$ per hour in the medium containing 15g/${\ell}$ gallic acid.

  • PDF

Estimating Length of Jeju Batdam Using Cadastral Information (지적 정보를 이용한 제주 밭담 길이 추정)

  • Park, Jong-Jun;Kwon, Yoon-Ku
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.3
    • /
    • pp.37-44
    • /
    • 2019
  • The value of Jeju Batdam has been reexamined as it is listed as a nationally important agricultural heritage and globally important agricultural heritage systems. However, it is already exposed to threats such as reduction of agricultural population and cultivation area. Despite efforts like the agricultural heritage system to preserve traditional agriculture, there is few basic investigation into the current status of Jeju Batdam. The purpose of this study is to estimate the length of Jeju Batdam. We used the continuous cadastral map of Jeju area to extract the boundaries of the field lot. In the cadastral map, the farmland was selected by selecting dry fields, paddy fields and orchards. 300 sample site were selected from the extracted farmland, and the boundaries between the Internet map and the parcels were superimposed and the differences were confirmed on the drawing. After that, field survey was conducted to confirm the boundary of the parcels and the existence of actual Batdam. It is estimated that the length estimated from this study is at least 23,983km and maximum 142,353km, which is at least 1,830km longer than 22,108km announced in 2007. Since Jeju Batdam is based on land parcel boundary, it is an objective and efficient method to utilize intellectual information. In addition, because it is subordinate to farmland, new information can be extracted reflecting the change of land use and make the spatial database based on the cadastral maps.

Automated Breast Ultrasound: Interobserver Agreement, Diagnostic Value, and Associated Clinical Factors of Coronal-Plane Image Features

  • Guoxue Tang;Xin An;Huiling Xiang;Lixian Liu;Anhua Li;Xi Lin
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.550-560
    • /
    • 2020
  • Objective: To evaluate the interobserver agreement, diagnostic value, and associated clinical factors of automated breast ultrasound (ABUS) coronal features in differentiating breast lesions. Materials and Methods: This study enrolled 457 pathologically confirmed lesions in 387 female (age, 46.4 ± 10.3 years), including 377 masses and 80 non-mass lesions (NMLs). The unique coronal features, including retraction phenomenon, hyper- or hypoechoic rim (continuous or discontinuous), skipping sign, and white wall sign, were defined and recorded. The interobserver agreement on image type and coronal features was evaluated. Furthermore, clinical factors, including the lesion size, distance to the nipple or skin, palpability, and the histological grade were analyzed. Results: Among the 457 lesions, 296 were malignant and 161 were benign. The overall interobserver agreement for image type and all coronal features was moderate to good. For masses, the retraction phenomenon was significantly associated with malignancies (p < 0.001) and more frequently presented in small and superficial invasive carcinomas with a low histological grade (p = 0.027, 0.002, and < 0.001, respectively). Furthermore, continuous hyper- or hypoechoic rims were predictive of benign masses (p < 0.001), whereas discontinuous rims were predictive of malignancies (p < 0.001). A hyperechoic rim was more commonly detected in masses more distant from the nipple (p = 0.027), and a hypoechoic rim was more frequently found in large superficial masses (p < 0.001 for both). For NMLs, the skipping sign was a predictor of malignancies (p = 0.040). Conclusion: The coronal plane of ABUS may provide useful diagnostic value for breast lesions.

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

A Study on the Analysis of the Relaxation Area and the Improvement Effect of the Ground by Road Subsidence (지하연속벽 배면 도로의 지반침하에 따른 이완영역분석방법과 지반 보강 효과검증에 관한 연구)

  • Lee, Hyoung Kyu;Lee, Yong-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.1
    • /
    • pp.29-41
    • /
    • 2021
  • Although underground works are essential to use underground spaces in urban areas efficiently, various damages caused by constructions have often occurred, making them major social problems. Since 2018, it is stipulated in the Special Act on Underground Safety Management that appropriate construction methods must be used in the design stage to prevent various damage cases. This Special Act includes establishing an area subject to underground safety impact assessment, analysis of ground and geological status, review of effects caused by changes in groundwater, review of ground safety, and establishment of measures to secure underground safety. This study area consists of various strata in order of landfill, sedimentary silt, sedimentary sand, sedimentary gravel, weathering zone, and foundation rock. Also, the slurry wall, a highly rigid underground continuous wall, was chosen as a construction method to consider high water table distribution and minimize the influence of the surroundings in this area. However, ground subsidence occurred on the road nearby in December 2019 due to the inflow of loosening soil to the construction area. Thus, several types of site investigations were conducted to suggest an appropriate analysis method and to find out loosed ground behavior and its area for the subsided site. As a result, new design soil properties were re-calculated, and the reinforcement measures were proposed through analytical verification.

A Treatment Case of Delayed Aortic Injury: The Patient with Posterior Rib Fracture

  • Park, Hyun-Seok;Ryu, Se-Min;Cho, Seong-Joon;Park, Sung-Min;Lim, Sun-Hye
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.406-408
    • /
    • 2014
  • A 66-year-old male patient arrived at the emergency room with a crush injury to his chest. Multiple rib fractures, hemothorax on both sides, left scapular fracture, liver laceration, and retroperitoneal hematoma were found upon the radiologic examination. After closed thoracostomy, the patient had been initially admitted to the intensive care unit, but he was transferred to the general ward on the next day. On the 4th post-trauma day, the patient complained of severe pain and there was bloody drainage through the chest tube. This case is an exploration with the consideration of the possibility of major bleeding and the subsequent repair of the descending thoracic aorta. This case is regarded as a case in which the aorta wall was damaged as the sharp margin of the fractured ribs caused continuous irritation.

Microbe-Based Plant Defense with a Novel Conprimycin Producing Streptomyces Species

  • Kwak, Youn-Sig
    • 한국균학회소식:학술대회논문집
    • /
    • 2015.05a
    • /
    • pp.54-54
    • /
    • 2015
  • Crops lack genetic resistance to most necrotrophic soil-borne pathogens and parasitic nematodes that are ubiquitous in agroecosystems worldwide. To overcome this disadvantage, plants recruit and nurture specific group of antagonistic microorganisms from the soil microbiome to defend their roots against pathogens and other pests. The best example of this microbe-based defense of roots is observed in disease-suppressive soils in which the suppressiveness is induced by continuously growing crops that are susceptible to a pathogen. Suppressive soils occur globally yet the microbial basis of most is still poorly described. Fusarium wilt, caused by Fusarium oxysporum f. sp. fragariae is a major disease of strawberry and is naturally suppressed in Korean fields that have undergone continuous strawberry monoculture. Here we show that members of the genus Streptomyces are the specific bacterial components of the microbiome responsible for the suppressiveness that controls Fusarium wilt of strawberry. Furthermore, genome sequencing revealed that Streptomyces griseus, which produces a novel thiopetide antibiotic, is the principal species involved in the suppressiveness. Finally, chemical-genetic studies demonstrated that S. griseus antagonizes F. oxysporum by interfering with fungal cell wall synthesis. An attack by F. oxysporum initiates a defensive "cry for help" by strawberry root and the mustering of microbial defenses led by Streptomyces. These results provide a model for future studies to elucidate the basis of microbially-based defense systems and soil suppressiveness from the field to the molecular level.

  • PDF