• Title/Summary/Keyword: Continuous performance test

Search Result 483, Processing Time 0.025 seconds

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

Optimization Design and Implementation of DC-DC Converter(LDC) for Electric Vehicle (전기자동차용 DC-DC 컨버터 최적설계)

  • Kwon, Yong-Hyo;Kim, Seung-Mo;Kim, Pyo-Soo;Kim, Mal-Su;Nam, Kwang-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.107-108
    • /
    • 2012
  • This paper presents design and implementation of the LDC(1.8 kW DC-DC Converter for Electric Vehicles). For Implementation of the LDC, the adapted topology is ZVS(Zero Voltage Switching) PSFB(Phase Shift Full Bridge) with Digital Control is adopted. Also, for the purpose of stable operation of the LDC in vehicle with variable electrical load condition, Continuous Voltage and Current Limit Control scheme based on PI controller are developed. According to real-car test mode, the prototype of proposed the LDC is verified with performance and stability. Thus, optimizing design and implement of the LDC are discussed, and experimental results are presented.

  • PDF

A study on the moving picture transmission method by railway fibers optics cable (광선로를 경유한 철도현장의 영상전송방안에 관한 연구)

  • Chang Seok-Gahk;Cho Bong-Kwan
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1465-1467
    • /
    • 2004
  • Compared with other transport means, safety and timeliness are the merits of railways. Unexpectedly when accident happens, much time and human strength are required to cope with the accident. And for swift recovery, systematic rehabilitation is needed. Recently using MTS(Moving picture Transmission System), we can perform accident rehabilitation and recording work efficiently. MTS is the device that transmits continuous picture information from accident field to control center. e are developing the appropriate system to railway situation to make use of the existing information communication technology, processing technology of video-tex, super high speed transmission technology through fiber-optic, copper cable and network description of information Technology, etc. If these communication-based can technologies are applied to railway system, railway managers can control the accident by inspecting the picture of accident field and can contribute to the safe train operation and the improvement of railway management. In this paper, we investigate the connecting methods when optical fiber is used for moving picture data transmission of train accidents, and its problems. And, we validate MTS's performance through about 28km section of field test.

  • PDF

A Study on the Drain Performance & Pore Structure of Cellular Mortar which Drain Material of the Composite Lining Method (Composite 라이닝 공법의 배수공 재료인 경량기포모르타르의 공극구조와 배수성능에 대한 고찰)

  • Choi, Hee-Sup;Ma, Sang-Joon;Lee, Heung-Soo;Seo, Shin-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.425-426
    • /
    • 2009
  • As a result of the Mercury Intrusion Porosimetry(MIP) test, FCR Batch with the continuous voids in excellent permeability is appeared with the Cellular Mortar that is most suitable which Drain Material of the Composite Lining Method.

  • PDF

Subjective Evaluation of Ultra-high Definition (UHD) Videos

  • Rahim, Tariq;Shin, Soo Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2464-2479
    • /
    • 2020
  • This paper presents a detailed subjective quality assessment for the ultra-high definition (UHD) videos having frame rates of 30fps and 60 fps. The subjective assessment is based on the ITU-R BT-500 recommendations, where double stimulus continuous quality scale (DSCQS-type II) test is performed for the evaluation of the perceived quality of the user's in terms of differential mean opinion score (DMOS). Encoding of the UHD videos by opting encoders i.e. H.264/AVC, H.265/HEVC, and VP9 at five different quantization parameter (QP) levels is done to investigate the perceived user's quality of experience (QoE) given as DMOS. Moreover, the encoding efficiency as the encoding time for each encoder and qualitative performance by employing full-reference (FR) quality metrics are presented in this work.

Track Longitudinal Irregularities at Bridge Deck Expansion Joint with ZLR(Zero Longitudinal Restraint) (활동체결장치가 설치된 교량상판 신축이음부에서의 궤도고저틀림에 미치는 영향)

  • Eom, Jong-Woo;Kim, Si-Chul;Kim, In-Jae
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1093-1098
    • /
    • 2007
  • In designing the high-speed railroad track, it is important to utilize appropriate track components to maintain uniform stiffness and ensure track alignment within the tolerance set for that system. In this regard, continuous welded rails (CWRs) were introduced to the Korean railways. Yet the installation of CWRs can result in an adverse impact due to the track/structure interaction on bridge sections yielding variations in the stiffness at the expansion joints. It may also impose additional axial force, generate excessive stress or deflection on track, and loosen the ballast at the ends as a bridge deck contracts or expands owing to a thermally-induced dynamic response. The risk is even greater in a long bridge deck, resulting in track longitudinal irregularities, deteriorating passenger's comfort, and increasing maintenance efforts. This study evaluates the performance of ZLR and their impact on track longitudinal irregularities through the track measuring results on a test section installed the ZLR in order to minimize the thermally-induced responses and the maintenance efforts for the high speed railway bridges.

  • PDF

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

3 Case Reports of ADHD Children treated with Acupuncture and Herbal Medicine (주의력결핍-과잉행동장애 아동 한방치료 3례)

  • Song, Beom-Yong;Yu, Gyung;Kim, Lak-Hyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.15 no.1
    • /
    • pp.239-246
    • /
    • 2004
  • Attention Deficit Hyperactivity Disorder(ADHD) is a common disease in children. This study is clinical case reports of 3 ADHD Children treated with acupuncture and herbal medicine. Two boys-one was 10 years old and the other was 8, and one girl-8 years old were treated with acupuncture and herbal medicine from March 2003 to May 2004. Acupoints-CV20(百會) CV24(上星) L7(列缺) LI4(合谷) Liv3(太衝) K3(太谿) was used and herbal medicine-Yukmijihwangtang(六味地黃湯) and Guibitang(歸脾湯) was used. T-score in ADS test(Continuous Performance Tests) checked after these treatments was lowered to the normal range, Conners' parent rating scale and Home Situations Questionaire score were lowered compared with those checked bfore treatment. These result suggest that acupuncture and herbal medicine could be one of helpful treatment to the ADHD children.

  • PDF

DEVELOPMENT OF THE SPACE CODE FOR NUCLEAR POWER PLANTS

  • Ha, Sang-Jun;Park, Chan-Eok;Kim, Kyung-Doo;Ban, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.45-62
    • /
    • 2011
  • The Korean nuclear industry is developing a thermal-hydraulic analysis code for safety analysis of pressurized water reactors (PWRs). The new code is called the Safety and Performance Analysis Code for Nuclear Power Plants (SPACE). The SPACE code adopts advanced physical modeling of two-phase flows, mainly two-fluid three-field models which comprise gas, continuous liquid, and droplet fields and has the capability to simulate 3D effects by the use of structured and/or nonstructured meshes. The programming language for the SPACE code is C++ for object-oriented code architecture. The SPACE code will replace outdated vendor supplied codes and will be used for the safety analysis of operating PWRs and the design of advanced reactors. This paper describes the overall features of the SPACE code and shows the code assessment results for several conceptual and separate effect test problems.

Study on The Measurement of Corrosion Product Concentration in The Feed Water System of A Power Plant (발전소 급수계통 부식생성물 농도 측정에 관한 연구)

  • Moon, Jeon Soo;Lee, Jae Kun
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.151-155
    • /
    • 2011
  • The iron oxide particles could be resulted from the corrosion of the circulating water system of a power plant. Because it may be one of the trouble materials which affect the power generation efficiency due to the deposition on steam generator tube and turbine blade, the continuous observation of its concentration is very important. The laser induced break-down detection (LIBD) technology was applied to monitor continuously the concentration of corrosion products with the detection limit of ppb level. The measurement system consists of a Nd:YAG pulsed laser, a polarizing beam splitter, a flow-type sample cell, an acoustic emission sensor, a high speed data acquisition board, a personal computer, etc.. The performance test results confirmed that this technology can be effective to monitor the corrosion product concentration of the circulating water system of a power plant.