• Title/Summary/Keyword: Continuous event

Search Result 331, Processing Time 0.024 seconds

Active Fault Study of the Yangsan Fault System and Ulsan Fault System, Southeastern Part of the Korean Peninsula

  • Kyung, Jai-Bok;Lee, Kie-Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.3
    • /
    • pp.219-230
    • /
    • 2006
  • Since the key issue that 'the Yangsan fault is seismically an active fault" was raised in 1983, thegeological and geomorphological studies of active fault have been made by many researchers. These studies are mainly focused on the Yangsan fault system(YFS) and Ulsan fault system(UFS) due to many historical earthquakes occurred in this area. There are two different types of active faultings under the ENE-WSW horizontal stress field in the southeastern part of the Korean Peninsula. The NNE-trending YFS is the most prominent right-lateral strike-slip fault and has a continuous trace about 200 km long. Some part of this system has been active during the late Quaternary with evidences clearly recognized on both the northern (Yugyeri and Tosung-ri areas) and southern parts (Eonyang to Tongdosa area) of the YFS. in the southern part, the estimated vertical slip rate is about 0.02 - 0.07 mm/yr, and the lateral slip rate may be several times larger than the vertical rate. The most recent event occurred prior to deposition of Holocene alluvium, in the northern part, the fault trend locally changes to almost N-S, dips to the east and has reverse movement. The average vertical slip rate is estimated to be less than 0.1 mm/yr. The most recent event probably occurred after 1314 years BP (AD 536). The NNW-SSE (or N-S) trending UFS is a predominantly reverse fault that built up U-ie eastern mountain and has been active during U-ie late Quaternary. The fault trace is not straight but irregularly undulates along the foot of the mountain on the east. From the disturbed terraces along U-ie fault, the average vertical slip rate on U-iis system is estimated to be about 0.08.13mm/yr. The latest event is not well studied, but seems to have occurred after the last glacial maximum in the Malbang fault and 14,000 years BP in the Kalgok fault of the UFS. However, important issues such as fault segmentation, recurrence interval, age of Quaternary deposits need further studies.

  • PDF

Water Quality Monitoring by Snowmelt in Songcheon, Doam Lake Watershed (도암호 유역의 융설에 의한 수질 변화 모니터링)

  • Kwon, Hyeokjoon;Hong, Dahye;Byeon, Sangdon;Lim, Kyoungjae;Kim, Jonggun;Nam, Changdong;Hong, Eunmi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.87-95
    • /
    • 2021
  • The Doam Lake Watershed is one of Gangwon-do's non-point source management areas. This area has a lot of snowfall in winter, and it is expected that there will be a lot of soil erosion in early spring due to snow melting. In this study, snow melting was monitored in the Doam Lake watershed from February to 3, 2020. It was conducted to analyze the water quality changes by calculating the concentration of non-point source pollution caused by snowmelt, and to compare the concentration of water quality during snowmelt event with rainfall and non-rainfall event. As a result of water quality analysis, Event Mean Concentration (EMC) at the first monitoring was SS 33.9 mg/L, TP 0.13 mg/L, TN 4.33 mg/L, BOD 1.35 mg/L, TOC 1.84 mg/L. At the second monitoring, EMC were SS 81.3 mg/L, TP 0.15 mg/L, TN 3.12 mg/L, BOD 1.32 mg/L, TOC 3.46 mg/L. In parameter except SS, it showed good water quality. It is necessary to establish management measures through continuous monitoring.

Research on Data Replication Method for Building an Enterprise Disaster Recovery System (엔터프라이즈 재해복구시스템 구축을 위한 데이터 복제 방안 연구)

  • Hyun-sun Kang
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.411-417
    • /
    • 2024
  • In the event of a disaster, it is essential to establish a disaster recovery plan and disaster recovery system to minimize disruption to major IT infrastructure and provide continuous business services. In the process of building a disaster recovery system, data replication is a key element of data recovery to provide uninterrupted and continuous business services in the event of a disaster. The data replication method can be determined depending on the system configuration environment and disaster recovery goal level. In this paper, we present a method for determining a data replication method suitable for the configuration environment and disaster recovery target level when building a disaster recovery system. In addition, the replication method decision procedure is applied to build a disaster recovery system and analyze the construction results. After establishing the disaster recovery system, a test was conducted to determine whether the service was transferred to the disaster recovery center in a disaster situation and normal service was provided, and the results were analyzed. As a result, it was possible to systematically select the optimal data replication method during the disaster recovery system construction phase. The established disaster recovery system has an RTO of 3.7 hours for service conversion to the disaster recovery center to provide continuous business services, and the disaster recovery level, which was Tier 2, has been improved to the target level within 4 hours of RTO and RPO=0.

A Study on analyzing the space of Villa VPRO used datascape design strategy (데이터스케이프 설계방법을 적용한 Villa VPRO 공간분석 연구)

  • 박영경
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.3
    • /
    • pp.145-152
    • /
    • 2004
  • The European architects including MVRDV, Rem Koolhaas, Van Berkel, and Zaha Hadid tend to use the their own design strategy based on the objective data. This Architectural design method leads to make new paradigm of contemporary architecture. For the purpose of the understanding a part of new architecture paradigm I will analyze the case of Villa VPRO designed by MVRDV. At the result, I can draw the following conclusions. First, through collecting and analyzing data, drawing design concept and planning the space program, they decided on the design strategies of Villa VPRO. They designed the space volume having 42.4m$\times$42.4m floors and infiltrated environmental elements to solve the problems about deep space. Second, Villa VPRO was constructed by 'creative space-making system: a series of floors much like a geological formation, the continuous floors interconnected by spatial means, the precision bombardments of snake-like holes, open elevations, the stacking spaces. Third, Villa VPRO produced the spectacle space effect the various formation of continuous floors make a lot of difference space types in this building. Also they lead to move naturally and give event space. A numbers of holes and openness make it possible to provide friendly environment with combining light and air with views of the surrounding and transparency. And using the method of stacking many types of space make the differences in height.

Runoff Analysis on the Physically-Based Conceptual Time-Continuous Runoff Model (물리적.개념적 연속 유출모형에 의한 유출해석)

  • 배덕효;조원철
    • Water for future
    • /
    • v.28 no.6
    • /
    • pp.193-202
    • /
    • 1995
  • The subjective research attempts to apply a rainfall-runoff model capable of considering time-variation of soil water contents which are highly correlated to the river flows on the qpqyungchang river basin and to evaluate its performance for flow forecasting. The model used in this study is a physically-based conceptual time-continuous model, which is composed of the Sacramento soil moisture accounting model and the nonlinear multiple conceptual reservoirs model. The daily precipitation and evaporation data for 7 years and for 3 years were used for the parameter estimation and the model verification, respectively. As a result, the flows including a significant flood event were well simulated, and the cross-correlation coefficient between observed flows and computed flows for the verification periods was 0.87, but in general computed flows were underestimated for the low-flow periods. Also, the effects of precipitation and soil water content to the river flows were analysed for the flood and the drought.

  • PDF

Design of a Stabilizing Controller for Hybrid systems with as Application to Longitudinal Spacing Control in a Vehicle Platoon (다중 Lyapunov 기방 하이브리드 시스템에 안정화 제어기 설계 및 군집 차량의 종방향 거리 제어시스템의 용용)

  • Kim, Jin-Byun;Park, Jae-Weon;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.6
    • /
    • pp.477-486
    • /
    • 2001
  • Many physical systems can be modeled by incorporating continuous and discrete event nature together. Such hybrid systems contain both continuous and discrete states that influence the dynamic be-havior of the systems. There has been an increasing interest in thers types of systems during the last dec-ade, mostly due to the growing usage of computers in the control of physical plants but also as a result of the hybrid nature of physical processes. The stability theory for hybrid systems is considered as extension of Lyapunov theory where the existence of an abstract energy function satisfying certain properties verifies stability, called multiple Lyapunov theory. In this paper, a hybrid stabilizing controller is proposed using the control Lyapunov function method and multiple Lyapunov theory, and the proposed method is applied to lon-gitudinal spacing control in a vehicle platoon for intelligent transportation systems(ITS).

  • PDF

Vibration Monitoring and Diagnosis System Framework for 3MW Wind Turbine (3MW 풍력발전기 진동상태감시 및 진단시스템 프레임워크)

  • Son, Jong-Duk;Eom, Seung-Man;Kim, Sung-Tae;Lee, Ki-Hak;Lee, Jeong-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.553-558
    • /
    • 2015
  • This paper aims at making a dedicated vibration monitoring and diagnosis framework for 3MW WTG(wind turbine generator). Within the scope of the research, vibration data of WTG drive train are used and WTG operating conditions are involved for dividing the vibration data class which included transient and steady state vibration signals. We separate two health detections which are CHD(continuous health detection) and EHD(event health detection). CHD has function of early detection and continuous monitoring. EHD makes the use of finding vibration values of fault components effectively by spectrum matrix subsystem. We proposed framework and showed application for 3MW WTG in a practical point of view.

Characteristics of $Si^+$ self implant Induced Damage and Its Annealing Behavior ($Si^+$ 이온주입된 Si 기판의 결함형성 및 회복에 관한 연구)

  • ;;;;;;Hiroshi Kuwano
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.91-99
    • /
    • 1994
  • Damage induced by Si ion implantation and its annealing behavior during rapid thermal annealing were investigated by cross-sectional TEM (transmission electron microscopy) and RB ( Rutherford backscattering) spectrum. 150keV and 50keV Si ions were implanted in Si (100) at room temperature with doses of 2${\times}10^{15}cm^{-2}$. And 100keV Si ions were implanted in Si with doses from 1${\times}10^{14}cm^{-2}$. A variety of damage structures were generated by Si ion implantation such as continuous amorphous layer extending to the surface buried amorphous layer and damage clusters. Damage clusters are annealed out at the lower annealing temperature of 550 $^{\circ}C$. However, event at the temperature of 110$0^{\circ}C$ end of range loops remain in the original lower amorphous/crystal interface in the case of continuous and buried amorphous layer formation. Extended defects in the shape of zipper dislocations are also observed at the middle of the recrystallized region in the buried amorphous layer.

  • PDF

On-Line Condition Monitoring and Diagnostics of Distribution Equipment (배전반 설비의 온라인 모니터링 및 진단)

  • Yun, Ju-Ho;Im, Wan-Su;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Development on an Automatic Calibration Module of the SWMM for Watershed Runoff Simulation and Water Quality Simulation (유역유출 및 수질모의에 관한 SWMM의 자동 보정 모듈 개발)

  • Kang, Taeuk;Lee, Sangho
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.4
    • /
    • pp.343-356
    • /
    • 2014
  • The SWMM (storm water management model) has been widely used in the world and is a watershed runoff simulation model used for a single event or a continuous simulation of runoff quantity and quality. However, there are many uncertain parameters in the watershed runoff continuous simulation module and the water quality module, which make it difficult to use the SWMM. The purpose of the study is to develop an automatic calibration module of the SWMM not only for watershed runoff continuous simulation, but also water quality simulation. The automatic calibration module was developed by linking the SWMM with the SCE-UA (shuffled complex evolution-University of Arizona) that is a global optimization algorithm. Estimation parameters of the SWMM were selected and search ranges of them were reasonably configured. The module was validated by calibration and verification of the watershed runoff continuous simulation model and the water quality model for the Donghyang Stage Station Basin. The calibration results for watershed runoff continuous simulation model were excellent and those for water quality simulation model were generally satisfactory. The module could be used in various studies and designs for watershed runoff and water quality analyses.