• 제목/요약/키워드: Continuous Scanning

검색결과 242건 처리시간 0.027초

Fatigue damage monitoring and evolution for basalt fiber reinforced polymer materials

  • Li, Hui;Wang, Wentao;Zhou, Wensong
    • Smart Structures and Systems
    • /
    • 제14권3호
    • /
    • pp.307-325
    • /
    • 2014
  • A newly developed method based on energy is presented to study the damage pattern of FRP material. Basalt fiber reinforced polymer (BFRP) is employed to monitor the damage under fatigue loading. In this study, acoustic emission technique (AE) combined with scanning electronic microscope (SEM) technique is employed to monitor the damage evolution of the BFRP specimen in an approximate continuous scanning way. The AE signals are analyzed based on the wavelet transform, and the analyses are confirmed by SEM images. Several damage patterns of BFRP material, such as matrix cracking, delamination, fiber fracture and their combinations, are identified through the experiment. According to the results, the cumulative energy (obtained from wavelet coefficients) of various damage patterns are closely related to the damage evolution of the BFRP specimens during the entire fatigue tests. It has been found that the proposed technique can effectively distinguish different damage patterns of FRP materials and describe the fatigue damage evolution.

우르소데옥시콜린산 및 케노데옥시콜린산의 베타시클로덱스트린 포접복합체의 물리화학적 특성비교 (Comparison of Physicochemical Properties between Ursodeoxycholic Acid and Chenodeoxycholic Acid Inclusion Complexes with ${\beta}-Cyclodextrin$)

  • 이승룡;정연복;한건;신재영
    • 약학회지
    • /
    • 제38권3호
    • /
    • pp.300-310
    • /
    • 1994
  • Physicochemical properties for the inclusion complex of chenodeoxycholic acid(CDCA) and it's $7{\beta}-hydroxy$ epimer ursodeoxycholic acid(UDCA) with ${\beta}-cyclodextrin({\beta}-CyD)$ were studied. The formation of the complex in the solid state were confimed by polarized microscopy and differential scanning calorimetry(DSC). Proton nuclear magnetic resonance$(^1H-NMR)$spectroscopy showed that CDCA and UDCA form an inclusion complex with ${\beta}-CyD$ in aqueous solution. The 1 : 1 stoichiometry of the complex was dextermined by the continuous variation method. From DSC and $^1H-NMR$ studies, there were not any differences between CDCA and UDCA. Complex of CDCA and UDCA showed increase in solubility and dissolution compared with CDCA and UDCA alone, respectively. Solubility pattern of UDCA complex was pH independent but, CDCA complex was like that of CDCA. Dissolution rate increased markedly in case of UDCA complex compared with CDCA complex, especially in acidic pH value.

  • PDF

Effect of Hydrophilic-Lipophilic Balance of Drugs on Their Release Behavior from Amphiphilic Matrix

  • Yoo, Young-Tai;Shin, Hyun-Woo;Nam, Byung-Guk
    • Macromolecular Research
    • /
    • 제11권4호
    • /
    • pp.283-290
    • /
    • 2003
  • Organic drugs including aspirin, omeprazole, and naproxen with three different levels of octanol/water partition coefficient were examined for their release behavior from the amphiphilic PCL-b-PEO-b-PCL (PCEC) matrix. Scanning electron micrograph (SEM) of PCEC illustrated a well defined two-phase morphology consisted of dispersed poly(ethylene oxide) (PEO) domain and continuous polycaprolactone (PCL) phase. Differential scanning calorimetry (DSC) and X-ray diffractometry (XRD) experiments veri tied that three model drugs are dissolved as a molecular dispersion in PCEC matrix. The release of hydrophilic aspirin closely followed the water absorption profile of the matrix indicating that its major fraction is present in PEO domain. However, substantial amount of aspirin present in less hydrophilic region displayed discontinuous biphasic release pattern. In the case of omeprazole with intermediate hydrophobicity consistent release behavior was observed for a period of 24 hrs after the rapid liberation of ca. 10% of the drug presumably partitioned in PEO phase. It was ascribed to the fact that the progressive hydration of PCEC matrix gradually increased the chance of drug/water exposure to compensate the exhaustion of device. Naproxen with the highest octanol/water distribution coefficient among three model drugs exhibited a limited release of 35% for 24 hrs. Finally, hydroxypropyl methylcellulose phthalate (HPMCP)/PCEC blend matrix demonstrated an accelerated and quantitative release of hydrophobic naproxen by generating high porosity and thereby expanding polymer/water interface.

수동형 FTIR 원격화학 탐지기를 이용한 SF6 오염운의 실시간 탐지 (Passive Remote Chemical Detection of SF6 Clouds in the Atmosphere by FTIR)

  • 정유진;박병황;김주현
    • 한국군사과학기술학회지
    • /
    • 제17권1호
    • /
    • pp.8-14
    • /
    • 2014
  • Brightness temperature spectra acquired from FTIR(Fourier Transform Infrared)-SCADS (Standoff Chemical Agent Detection System) could be available for detection and identification of the chemical agents and pollutants from different background. IR spectrum range of 770 to 1350 $cm^{-1}$ is corresponding to "atmospheric window". A 2-dimensional(2D) brightness temperature spectrum was drawn from combining each data point through automatic continuous scanning of FTIR along with altitude and azimuth. At higher altitude, temperature of background was decreased but scattering effect of atmospheric gases was increased. Increase in temperature difference between background and blackbody in SCADS at higher temperature causes to increases in peak intensity of $SF_6$. This approach shows us a possibility that 2D visual information is acquired from scanning data with a single FTIR-SCADS.

디지털 인체 계측 방법의 유형 및 특성 (Types and Characteristics of Digital Anthropometric Methods)

  • 김리라
    • 패션비즈니스
    • /
    • 제25권5호
    • /
    • pp.88-98
    • /
    • 2021
  • In this study, the characteristics of digital anthropometric methods were determined with case studies. These methods were broadly classified into two categories: non-wearable and wearable. Then, these categories were further classified into four types: 3D Scanning, mobile app, smart clothing, and smart tool Among the non-wearable types, the "3D scanning" technique was based on the use of 3D hardware equipment. With this technique, the body shape was measured and the internal body information was obtained. Therefore, it is used in fields of healthcare and fitness. Among the wearable types, "Smart clothing" involves a special clothing that measures human body and a smartphone application. Both the components are linked to a fashion platform, which is based on the measured sizes that help shoppers. The "Smart tool" has the characteristic of measuring only with smart tools and smartphone applications; it does not involve the measurement of images. The common advantage of digital anthropometric methods are as follows: they reduce the time and cost of measurement by enabling self-measurement. Moreover, simple measurements are used to determine the size of anthropometry. Thereafter, it accumulates this data to track the continuous changes in size. From an industrial point of view, digital anthropometric technology should be used to increase sales. The on-demand market can be expanded as global consumers would throng the Korean fashion market. For the consumer, an avatar should be created to fit the user's size. This would provide a fun experience to the user.

Composite components damage tracking and dynamic structural behaviour with AI algorithm

  • Chen, Z.Y.;Peng, Sheng-Hsiang;Meng, Yahui;Wang, Ruei-Yuan;Fu, Qiuli;Chen, Timothy
    • Steel and Composite Structures
    • /
    • 제42권2호
    • /
    • pp.151-159
    • /
    • 2022
  • This study discusses a hypothetical method for tracking the propagation damage of Carbon Reinforced Fiber Plastic (CRFP) components underneath vibration fatigue. The High Cycle Fatigue (HCF) behavior of composite materials was generally not as severe as this of admixture alloys. Each fissure initiation in metal alloys may quickly lead to the opposite. The HCF behavior of composite materials is usually an extended state of continuous degradation between resin and fibers. The increase is that any layer-to-layer contact conditions during delamination opening will cause a dynamic complex response, which may be non-linear and dependent on temperature. Usually resulted from major deformations, it could be properly surveyed by a non-contact investigation system. Here, this article discusses the scanning laser application of that vibrometer to track the propagation damage of CRFP components underneath fatigue vibration loading. Thus, the study purpose is to demonstrate that the investigation method can implement systematically a series of hypothetical means and dynamic characteristics. The application of the relaxation method based on numerical simulation in the Artificial Intelligence (AI) Evolved Bat (EB) strategy to reduce the dynamic response is proved by numerical simulation. Thermal imaging cameras are also measurement parts of the chain and provide information in qualitative about the temperature location of the evolution and hot spots of damage.

Characterization and Corrosion Behaviour of Zn-Sn Binary Alloy Coatings in 0.5 M H2SO4 Solution

  • Fatoba, O.S.;Popoola, A.P.I.;Fedotova, T.
    • Journal of Electrochemical Science and Technology
    • /
    • 제6권2호
    • /
    • pp.65-74
    • /
    • 2015
  • This work examines the characterization and corrosion behaviour of laser alloyed UNSG10150 steel with three different premixed composition Zn-Sn binary powders using a 4.4 kW continuous wave (CW) Rofin Sinar Nd:YAG laser processing system. The steel alloyed samples were cut to corrosion coupons, immersed in sulphuric acid (0.5 M H2SO4) solution at 30℃ using electrochemical technique and investigated for its corrosion behaviour. The morphologies and microstructures of the developed coated and uncoated samples were characterized by Optic Nikon Optical microscope (OPM) and scanning electron microscope (SEM/EDS). Moreover, X-ray diffractometer (XRD) was used to identify the phases present. An enhancement of 2.7-times the hardness of the steel substrate was achieved in sample A1 which may be attributed to the fine microstructure, dislocations and the high degree of saturation of solid solution brought by the high scanning speed. At scanning speed of 0.8 m/min, sample A1 exhibited the highest polarization resistance Rp (1081678 Ωcm2 ), lowest corrosion current density icorr (4.81×10−8A/cm2 ), and lowest corrosion rate Cr (0.0005 mm/year) in 0.5 M H2SO4. The polarization resistance Rp (1081678 Ωcm2 ) is 67,813-times the polarization of the UNSG10150 substrate and 99.9972% reduction in the corrosion rate.

수종의 접착제를 사용한 아말감 수복시의 미세 변연 누출에 관한 연구 (MICROLEAKAGE EVALUATION IN AMALGAM RESTORATIONS USED WITH BONDING AGENTS)

  • 최상철;박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.447-463
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of copal varnish and five bonding agents(Scotchbond Multi-Purpose Plus Dental Adhesive System, Panavia 21, All Bond 2, Superbond D-Liner II plus, Fuji Duet) in reducing microleakage under amalgam restorations. Class V cavity were prepared on both buccal and lingual surface of sixty extracted human molars with cementum margin and were filled with different kinds of liners and amalgam. All teeth were stored at $37^{\circ}C$ in physiologic saline solution. After 1 week they were thermally stressed for 500 cycles between 5 and $55^{\circ}C$ in baths containing 0.5 % basic fuchsin dye. The dye penetrations were observed with a stereomicroscope. Scanning electron micrographs were taken of representative tooth sections from each group to assess the nature of the tooth/liner/amalgam interface. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The results were as follows ; 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. At the dentin and enamel margins, the leakage value of Copalite-lined group showed significantly higher than that of no liner group (p<0.05), but showed significantly lower than that of bonding agent lined-groups (p<0.05). 3. There was no significant difference between the bonding agent lined-groups (p>0.05). 4. On the backscattered scanning electron microscopy observation, discontinuous gaps were observed between amalgam and dentin in the bonding agent-lined amalgam restorations and the bonding agents appeared to fill the gap space and were mixed with amalgam particles. At the amalgam/tooth interface, unsealed dentin and continuous gaps were found in both unlined and Copalite-lined restorations.

  • PDF

Preparation and Gas Permeability of ZIF-7 Membranes Prepared via Two-step Crystallization Technique

  • Li, Fang;Li, Qiming;Bao, Xinxia;Gui, Jianzhou;Yu, Xiaofei
    • Korean Chemical Engineering Research
    • /
    • 제52권3호
    • /
    • pp.340-346
    • /
    • 2014
  • Continuous and dense ZIF-7 membranes were successfully synthesized on ${\alpha}-Al_2O_3$ porous substrate via two-step crystallization technique. ZIF-7 seeding layer was first deposited on porous ${\alpha}-Al_2O_3$ substrate by in-situ low temperature crystallization, and then ZIF-7 membrane layer can be grown through the secondary high-temperature crystallization. Two synthesis solutions with different concentration were used to prepare ZIF-7 seeding layer and membrane layer on porous ${\alpha}-Al_2O_3$ substrate, respectively. As a result, a continuous and defect-free ZIF-7 membrane layer can be prepared on porous ${\alpha}-Al_2O_3$ substrate, as confirmed by scanning electron microscope. XRD characterization shows that the resulting membrane layer is composed of pure ZIF-7 phase without any impurity. A single gas permeation test of $H_2$, $O_2$, $CH_4$ or $CO_2$ was conducted based on our prepared ZIF-7 membrane. The ZIF-7 membrane exhibited excellent H2 molecular sieving properties due to its suitable pore aperture and defect-free membrane layer.

Terephthalic Acid 분해 세균의 분리 및 특성 (Isolation and Characterization of Terephthalic Acid-degrading Bacteria)

  • 김재화;이창호;우철주;주길재;서승교;박희동
    • 한국미생물·생명공학회지
    • /
    • 제27권2호
    • /
    • pp.118-123
    • /
    • 1999
  • A bacterial strain, designated T116, degrading terephthalic acid (TPA) was isolated from the soil around Taegu industrial area into which dye works wastewater flow. The isolate was identified as pseudomonas sp. based on its morphological and physiological characteristics. Degradation of TPA by the strain T116 was confirmed with UV scanning and HPLC. About 90% and 98% of TPA were degraded after 36 and 60 hours, respectively, during the culture in a liquid medium containing 0.1% TPA. Addition of KH2PO4 at a final concentration of 100ppm enhanced the chemical oxygen demand (COD) removal rate about 50% from dye works wastewater by Pseudomonas sp. T116. Optimum pH and temperature for COD reduction from wastewater were 7.0 and 3$0^{\circ}C$, respectively. The bacterium was applied to the continuous culture for the treatment of dye works wastewater whose TPA concentration and CODMn were 2,200ppm and 1,620ppm, respectively. It was observed that 90-95% of COD was eliminated after 4 days culture in the continuous culture with a retention time of 37 or 47 hours.

  • PDF