• Title/Summary/Keyword: Continuous Motion Effect

Search Result 88, Processing Time 0.021 seconds

The Effect of Continuous Passive Motion and Continuous Active Motion on Joint Proprioception After Total Knee Replacement (슬관절전치환술 후 연속수동운동(CPM)과 연속능동운동(CAM) 적용이 관절 고유수용감각에 미치는 영향)

  • Yang, Jin-Mo;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.1_2
    • /
    • pp.41-52
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the effects of continuous passive motion(CPM) and continuous active motion(CAM) on proprioception of the knee after total knee replacement(TKR). Methods: Twenty patients with TKR were randomly allocated into two groups, the CPM group(n=10) and the CAM group(n=10). All subjects were evaluated for levels of pain, passive range of motion and angle reproduction of the knee. An angle reproduction test was used to assess the proprioceptive deficit. Two types of angle reproduction test were used: a passive angle reproduction(PAR) test and an active angle reproduction(AAR) test. The relevant examinations were performed before and after intervention(on the 5th day and the 10th day). The statistical significance were calculated using a t-test and a one-way repeated ANOVA. Results: A pre-intervention significant difference was not found between the two groups. Significantly better results were before and after the intervention at 10 days, for the PAR(flexion direction) test; however, only in the CAM group. There were no significant difference, either before or after the intervention, for the AAR test(flexion and extension direction) in both group. Both groups experienced similar levels of pain and passive range of knee motion before and after the intervention. Conclusion: This study revealed that CAM was a better effect to restore position sense of the knee joint after TKR.

  • PDF

Correction of Continuous Motion Effects for Airborne FMCW-SAR System (항공기 기반 FMCW-SAR 시스템의 연속이동효과 보정)

  • Hwang, Ji-hwan;Jung, Jungkyo;Kim, Duk-jin;Kim, Jin-Woo;Shin, He-Sub;Ok, Jae-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.410-418
    • /
    • 2017
  • Results of an analysis of the continuous motion effect for FMCW-SAR system and a signal processing to correct it are presented in this paper. SAR images reconstructed by back-projection algorithm are included as well. To analyze how platform velocity and sampling frequency affect the continuous motion effect, FMCW signal model was used, and the signal processing in time-doppler(t, $k_u$) domain was adopted. Then, back-projection algorithm and modified matched-filter was used to reconstruct SAR images, and it was validated using measured data by airborne FMCW-SAR system in X-band frequency.

Analysis of 32m aerostat gust load using non-linear cable equation (비선형 테더 방정식을 이용한 에어로스탯 돌풍하중해석)

  • Kang, Wang-Gu;Lee, In;Kim, Dong-Min
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.757-761
    • /
    • 2008
  • The aerostat dynamic equation of motion has been built including the tether cable dynamic effects. A numerical program to solve the derived equation of motion has been developed. The dynamic motion of the 32m aerostat has been analyzed under discrete gust and continuous turbulence. The aerostat behaviors under discrete gust which represents a deterministic approach for determining design loads for manned aircraft are solved to verify the effect of aerostat mechanical properties on the aerostat dynamic behavior. Continuous turbulences are simulated for each given altitude, translational mean wind velocity and gust intensity. Dynamic behaviors of the 32m aerostat are simulated for each continuous turbulence conditions. Translational and vertical velocity and pitching behavior and tether reaction force are monitored for each simulation.

  • PDF

The Effects of Pain and Range of Motion by Continuous Wave Ultrasound and Pulsed Wave Ultrasound on Patient with Temporomandibular Joint Disability (측두하악관절장애 환자에서 연속초음파와 맥동초음파 적용이 통증과 관절가동범위에 미치는 효과)

  • Moon, Hyun-Ju;Seo, Hyun-Kyu;Gong, Won-Tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the effect of continuous wave ultrasound and pulsed wave ultrasound that influence changes in pain and range of motion when applied to patients with temporomandibular joint disability. Methods: The subjects of the study were 40 selected patients who had been diagnosed with temporomandibular joint movement restriction and had endured pain for more than two weeks. These patients had visited K orthopedic surgery in Deagu measured from October 1, 2004 to March 31, 2005. The subjects were divided into two groups with 20 patients each. The one group was applied to continuous wave ultrasound and the other group was applied to pulsed wave ultrasound at a dosage of 1.5 W/$cm^2$ for a duration of 5 minutes and eight times for two weeks. The pain perception degree were measured by using Visual Analogue Scale(VAS) and the range of motion was measured by using a rule for each group. Results: The results obtained were as follows The change in the pain perception degree were statistically significant in both group(p<0.05) ; however, the continuous wave ultrasound group showed more difference in the average decrease in the pain perception degree than did the pulsed wave ultrasound group. Both groups showed significant results regarding changed in the range of motion(p<0.05) ; Comparing the difference in the average of the range of motion between the two groups, came back from normal the range of motion of temporomandibular joint at the both groups. Conclusion : Based on the results of this study, we found that both groups showed decreased pain and increased the range of motion, but the continuous wave ultrasound method had a higher therapy effect pain and the range of motion than the pulsed wave ultrasound method to patients with temporomandibular joint disability. With such finding, we expect that according to ultrasound therapy applicant method can be helped usable accurately to patients with variety symptoms temporomandibular joint disability.

  • PDF

Immediate Effect of Intermittent Versus Continuous Hamstring Static Stretching on the Muscle Tone and Range of Motion

  • Chen, Jin-Gyi;Choi, Eun-Hong;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.4
    • /
    • pp.19-27
    • /
    • 2019
  • PURPOSE: This study examined which stretching exercise had the most positive effect on increasing the range of motion (ROM) of the knee joint in healthy people and whether there was a difference between continuous stretching and intermittent stretching. METHODS: This study included 30 healthy university students from OOO University. The subjects were asked to sit on a mat and perform hamstring-stretching exercise during which the ROM and muscle tone were measured with pre and post-tests. Each subject was assigned randomly to a continuous stretching group (stretching without relaxation time group, n=10, G1) or intermittent stretching group (stretching with 10s relaxing time group, n=10, G2; and stretching with 20s relaxing time group, n=10, G3). The participants conducted hamstring stretching exercises with a sit-and-reach box at three different rest times (0s, 10s, and 20s). Subsequently, they underwent passive knee extension (PKE) tests, in which the ROM of the knee joint was measured with a goniometer, and the muscle tone was evaluated using a MyotonPro. RESULTS: Significant differences in muscle tone, stiffness, and ROM were observed between pre-test and post-test in each groups (p<.05). Although the post hoc tests indicated no significant differences in muscle tone and ROM between the continuous stretching group and intermittent stretching group (p>.05), the rate of change of the ROM showed that the intermittent stretching group developed more effective maintenance of the hamstring flexibility. CONCLUSION: No significant differences in the muscle tone of the hamstring and ROM of the knee joint were observed according to the hamstring stretching exercises with three different rest times. On the other hand, the rate of change of the ROM showed that intermittent stretching maintained the hamstring flexibility more effectively.

The Effects of CPM (Continuous Passive Motion) on Hand Function and Muscular Strength for Patients with Stroke (CPM (Continuous Passive Motion) 사용이 뇌졸중 환자의 손 기능과 근력향상에 미치는 영향)

  • Jeong, In-Seon
    • Therapeutic Science for Rehabilitation
    • /
    • v.3 no.2
    • /
    • pp.71-81
    • /
    • 2014
  • Objective: The purpose of this study is to ob serve effects of CPM(Continuous Passive Motion) on hand functional and upper-extremity muscular strength rehabilitation for stroke patients. Method: Objects of this study, three patients have the symptoms of hemiplegia due to stroke. These are acute patients, within a 18 months after treatment and correspond in Brunnstrom stage 4~6. This study used single subject (A-B) design for three patients with a stroke and the effect of CPM was measured using Jebsen-Taylor hand function test, Purdue Pegboard test, hand muscular strength test. They received CPM for 3 weeks, 2 per day, 30 minutes for each, total 30 times. Results: Two patients' results of fingertip grip test in hand strength measurements did not change. Results of Jebsen-Taylor hand function test, Purdue Pegboard test and other hand muscular strength test were improved. To validate statistical results nonparametric statistical method, Wilcoxon signed ranks test was performed. P-Values are greater than 0.05 so difference between be fore and after treatment is not statistically significant result. Conclusion: Despite of limitation of short program period and fewer participants, CPM which has been conducted for stroke patients showed the effect on improvement of hand function and muscle strength. This study shows that CPM which is mainly used to treate lower-extremity rehabilitation can be use to improve performance of hand function and strength for patients with stroke.

Dynamic Analysis of Multi-Span Continuous Bridges under Combined Effects of Earthquake and Local Scour (지진과 세굴의 복합적인 영향을 받는 연속교의 동적거동분석)

  • 김상효;마호성;이상우;심정욱
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.166-173
    • /
    • 2002
  • Seismic bridge failure due to the combined effects of earthquake and local scour are examined in probabilistic perspectives. The seismic responses of multi-span continuous bridge with deep foundations are evaluated with a simplified mechanical model. The probabilistic local scour depths around the deep foundations are estimated by using the Monte Carlo simulation. From the simulation results, it is found that seismic responses of a bridge slightly increase due to the local scour effect. The effect of local scour on the global motion of the continuous bridge is found to be significant under weak seismic intensity. In addition, the duration to regain its original foundation stiffness is critical in estimating the probability of foundation failure under earthquake. Therefore, the duration in recovering the foundation stiffness should be determined reasonably and the safely of the whole bridge system should be evaluated by considering the scour effect.

  • PDF

An experimental study on the relationship between longitudinal and lateral motion of a moving web (장력과 사행거동의 상호작용에 관한 실험적 연구)

  • Sin, Gi-Hyeon;Gwon, Sun-O
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2003.11a
    • /
    • pp.209-216
    • /
    • 2003
  • There are two kinds of controllers in a continuous process system. One is for tension control of a moving web and the other for lateral motion control. The inter-connection between tension and lateral behaivior of web has not yet been considered in the analysis of web dynamics and designing of control stragagies. But the effect of tension variation on the lateral motion of a moving web is observed in the most manufacturing systems. In this paper, experimental studies was carried out to find out the inter-correlation between tension and lateral motion of a web using a 3-span web transport system which consists of two displacement type guiders. As a result, it was found that there are typical operating conditions that tension and lateral motion are correlated each other.

  • PDF

Analgesia After Subacromial Arthroscopy: Prospective Double-blind Study of Continuous Mixed Intra-bursal Infusion with Morphine and Bupivacaine and placebo (견봉하 관절경 수술 후 진통 작용: 모르핀과 국소마취제 혼합제와 위약의 점액낭 내 지속 주입에 대한 전향적 이중 맹검 연구)

  • Park Jin-Young;Lee Kwan-Woo;Kim Yun;Yoo Moon-Jib
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.102-108
    • /
    • 2000
  • The aim of this study is to determine if intra-bursal morphine and Bupivacaine mixed infusion provided useful analgesia after subacromial arthroscopic operation. At the end of the subacromial arthroscopy, continuous intra-bursal infusion catheter was inserted. In a double-blind randomized trial, Sixty patients were allocated to one of two groups: placebo group(n=30) received continuous saline infusion. Study group received mixed 5㎖ of 0.5% Bupivacaine, 2㎎ of morphine and 0.05㎖ of 1/1000 epinephrine as bolus and mixed solution of 40㎖ of 0.5% Bupivacaine and 8㎎ of morphine as maintenance dose with continuous infusion pump(0.5㎖ hourly). In the placebo group, two patients were discontinued due to leakage and catheter coming out each. Intensity of pain was evaluated preoperatively and postoperatively for 3 days by 10 graded visual analogue scale. Night pain, pain on motion, sleep disturbance, lying on painful shoulder and amounts of intramuscular pain killer were recorded. Analgesic effect for pain was cleared at 1st and 2nd postoperative day and there was less sleep disturbance for 3 days postoperatively in study group. There was no difference in pain on motion postoperatively. In study group, less pain killers were used in the first 48 hours postoperatively. The continuous intra-bursal infusion decreased perception of pain at resting stage and reduced supplemental analgesic requirement for 2 days postoperatively.

  • PDF

Effect of Temperature on Photoinduced Reorientation of Azobenzee Chromophore in the Side Chain Copolymers

  • 최동훈
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.9
    • /
    • pp.1010-1016
    • /
    • 1999
  • We synthesized the photoresponsive side chain polymers containing aminonitro azobenzene for studying the effect of temperature on photoinduced birefringence. Four different copolymers were prepared using methacrylate, α-methylstyrene, and itaconate monomer. Photoisomerization was observed under the exposure of UV light using UV-VIS absorption spectroscopy. Reorientation of polar azobenzene molecules induced optical anisotropy under a linearly polarized light at 532 nm. The change of the birefringence was observed with increasing the sample temperature under a continuous irradiation of excitation light. We could estimate the activation energy of molecular motion in thermal and photochemical mode. Besides the effect of glass transition temperature on the activation energy, we focused our interests on the effect of geometrical hindrance of polar azobenzene molecules and cooperative motion of environmental mesogenic molecules in the vicinity of polar azobenzene molecules.