• Title/Summary/Keyword: Continuous Monitoring

Search Result 1,556, Processing Time 0.03 seconds

A Continuous Evaluation Processes for Information Security Management

  • Choi, Myeonggil
    • Journal of Information Technology Applications and Management
    • /
    • v.23 no.3
    • /
    • pp.61-69
    • /
    • 2016
  • Growing information threats have threatened organization to lose information security controls in these days. Many organizations have accepted the various information security management systems does mention necessity of a continuous evaluation process for the executions of information security management in a theoretical aspect. This study suggests a continuous evaluation process for information security management reflecting the real execution of managers and employees in organizations.

Transient Neonatal Diabetes Mellitus Managed with Continuous Subcutaneous Insulin Infusion (CSII) and Continuous Glucose Monitoring

  • Kim, Min Soo;Kim, Sung Eun;Lee, Na Yeong;Kim, Seul Ki;Kim, Shin Hee;Cho, Won Kyoung;Cho, Kyoung Soon;Jung, Min Ho;Suh, Byung-Kyu;Ahn, Moon Bae
    • Neonatal Medicine
    • /
    • v.28 no.1
    • /
    • pp.41-47
    • /
    • 2021
  • Neonatal diabetes mellitus can be categorized as transient, permanent, or syndromic, and approximately half of the cases are transient. We present a case involving a term newborn who showed overt progression of transient neonatal diabetes mellitus, with complete remission within 6 months. On the second day of life, the patient presented with tachypnea, hyperglycemia, and decreased serum levels of C-peptide and insulin. Continuous subcutaneous infusion of insulin and continuous glucose monitoring were well tolerated. The patient showed a normal growth pattern, with no hyperglycemic or hypoglycemic episodes at 6 months of age. As it is rare and often asymptomatic, hyperglycemia may be attributed to various factors, including intrauterine environment, perinatal stress, and diverse genetic background. Therefore, consistent blood glucose monitoring and prompt early insulin therapy are crucial for any term newborns with persistent hyperglycemia, to prevent further diabetic complications. Moreover, continuous subcutaneous insulin infusion and the utilization of continuous glucose monitoring devices are the most effective and practical management strategies.

On-Line Diagnostics and Monitoring of Distribution Panel Using IR-Sensor (광온도센서를 이용한 분전반의 온라인 진단 및 감시)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2110-2111
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Monitoring Management Plan for Changed Region with respect to Revision Periods (변화지역에 대한 갱신주기별 모니터링 운영방안)

  • Han, You Kyung;Yeom, Jun Ho;Kim, Yong Il;Lee, Byoung Kil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.5
    • /
    • pp.401-410
    • /
    • 2013
  • Due to the increasing need for spatial information, there have been a lot of research related with monitoring and revision of changed regions for the acquisition of the accurate and latest information. In this paper, the optimal monitoring management plan for changed regions with respect to the revision periods was proposed. For this purpose, the representative monitoring methods, which are based on database, professional manpower and crowdsourcing of continuous revision, and aerial imagery, satellite imagery and LiDAR of cyclic revision, were investigated. Then, the properties and application status of monitoring systems in Korea were illustrated according to the methods. Finally, the optimal monitoring management plan for continuous and cyclic revisions was suggested through the comparison of properties and revisionable objects of each method. From the result, it was shown to be appropriate for the optimal monitoring management plan of continuous revision as using Internet-Architectural Information System (e-AIS) database cooperated with professional manpower and crowdsourcing, and cyclic revision as using domestic high-resolution satellite images and LiDAR data processed semi-automatically.

Trends in Non-invasive Continuous Glucose Monitoring Technology (비침습 연속혈당 모니터링 기술동향)

  • Kim, J.;Kim, B.K.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.5
    • /
    • pp.9-20
    • /
    • 2021
  • A technology to replace the traditional blood sampling method for glucose monitoring has been sought for a long time. It is now possible to measure the blood glucose change rate continuously for more than 24 hours using a minimally invasive method that does not involve blood collection. Furthermore, various technology development efforts are being made for innovative diabetes management through intermittent or continuous blood glucose monitoring in a non-invasive manner. In this paper, we present an overview of diabetes and the need for continuous blood glucose measurement techniques., and then introduce various non-invasive blood glucose measurement techniques currently being studied. In addition, through research and analysis of the recent commercialization development status of minimally invasive, non-invasive, and wearable continuous blood glucose measurement technologies, we examine global development trends of future technologies.

A Safety Analysis of Tunnel Lining for Monitoring (계측에 의한 터널 라이닝의 안전성 분석)

  • Woo, Jong-Tae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.103-110
    • /
    • 2002
  • Maintenance monitoring of the tunnel which offers continuous data during and after tunneling has been applying to tunnels in order to meet the maintenance of tunnel and to confirm continuous security of the tunnel after tunneling. But, the maintenance monitoring of tunnel results for long period is not easy to find, and moreover, the rational analysis method on tunnel monitoring has not been established yet. In this study, the relationships between displacement and stress of the tunnel concrete lining using various analysis methods are compared with maintenance monitoring. The tunnel behavior were measured in the subway tunnel passing comparative soft the weathering and analyzed both security and mechanical characteristics of the tunnel concrete lining. Also, analyzed relationship between residual water pressure applied on tunnel design and one obtained by monitoring.

Application of Computer-coupled Mass Spectrometer for Continuous On-line Monitoring of Cell Growth and Growth Rate (세포증식과 증식속도의 On-line Monitoring을 위한 Computer- coupled Mass Spectrometer의 응용)

  • 남수완;최춘순;김정회
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.241-246
    • /
    • 1989
  • Continuous on-line monitoring of cell concentration and growth rate in aerobic batch fermentation process was carried out by analyzing the exhaust gas composition of tormentor with a quadrupole mass spectrometer. From the mass spectrometric analyses of major gaseous components, i.e. $N_2$, $O_2$, $CO_2$ and $H_2O$, and the material balance equations for oxygen and carbon dioxide, oxygen uptake rate (OUR) rind carbon dioxide evolution rate (CER) were instantaneously calculated using a computer (16-bit IBM PC-AT) interfaced to a quadrupole mass spectrometer. The calculated OUR and CER data were used for the estimation of cell concentration and growth rate of Candida utilis during batch culture. It was found that the cell concentration could be satisfactorily estimated from the data of OUR arid CER during the culture and this method could be successfully und for the continuous monitoring of cell growth and growth rate.

  • PDF

Sequential patient recruitment monitoring in multi-center clinical trials

  • Kim, Dong-Yun;Han, Sung-Min;Youngblood, Marston Jr.
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.5
    • /
    • pp.501-512
    • /
    • 2018
  • We propose Sequential Patient Recruitment Monitoring (SPRM), a new monitoring procedure for patient recruitment in a clinical trial. Based on the sequential probability ratio test using improved stopping boundaries by Woodroofe, the method allows for continuous monitoring of the rate of enrollment. It gives an early warning when the recruitment is unlikely to achieve the target enrollment. The packet data approach combined with the Central Limit Theorem makes the method robust to the distribution of the recruitment entry pattern. A straightforward application of the counting process framework can be used to estimate the probability to achieve the target enrollment under the assumption that the current trend continues. The required extension of the recruitment period can also be derived for a given confidence level. SPRM is a new, continuous patient recruitment monitoring tool that provides an opportunity for corrective action in a timely manner. It is suitable for the modern, centralized data management environment and requires minimal effort to maintain. We illustrate this method using real data from two well-known, multicenter, phase III clinical trials.

Study on the Improvement of Dietary Life of Cancer Patients during Treatment by Nutrition Counseling (암 치료 시 영양상담을 통한 식생활 개선에 관한 연구)

  • Hong, Keeyoun;Choi, Yunjin;Yan, Wanqin;Lim, Hyunsook;Chyun, Jonghee
    • Korean Journal of Community Nutrition
    • /
    • v.21 no.1
    • /
    • pp.93-101
    • /
    • 2016
  • Objectives: This study investigated the improvement of food habits and eating behavior of cancer patients during treatment through the continuous nutrition counseling and monitoring. Methods: Thirty cancer patients during treatment were participated in this study, and the first nutrition counseling and the first and second monitoring were conducted after 2-3 week intervals. Results: As a result of the nutrition counseling and monitoring, all patients improved to a great extent to consume 3 meals a day. The frequency of having breakfast was significantly increased with the nutrition counseling and continuous monitoring as well. The meal fixed quantity was stabilized and the eating speed slowed down as more nutrition counseling were done. The snack intakes of patients did not show any significant difference after the nutrition counseling but showed a slight decline after the monitoring. The frequencies of eating out and a late-night meal significantly decreased after the monitoring. The intakes of fish, meat, vegetables, milk and fruits needed for a well-balanced diet significantly increased as more nutrition counseling were done. The intakes of processed food were significantly decreased after the nutrition counseling and the intakes of fast food were significantly decreased as more nutrition counseling were done. The water intake of patients also significantly increased. In the eating behavior related to health, the frequency of drinking alcohol significantly decreased after nutrition counseling consultation and no patients had dietary supplements after the first monitoring. Conclusions: These results suggested that continuous nutrition counseling is effective in improving eating habits of cancer patients.

Performance of Self-Manufactured Ion Selective Microelectrode (ISME) for Continuous Monitoring of Ammonia and Nitrate Ions

  • Byun, Im-Gyu
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1449-1454
    • /
    • 2012
  • The ion selective microelectrodes (ISME) have been applied to observe the continuous profiles of NO3-N and NH4-N in bulk solutions or biofilms. In order to evaluate the performance and applicability of ion concentration measuring system, the characteristics, such as slope of calibration curve, detection limit and potentiometric selectivity coefficient were investigated. The slopes of calibration curve showed high degree of correspondence for each target ion concentrations. And the detection limits of nitrate and ammonia ion selective microelectrode were 10-4.7 M and 10-4.4 M, respectively. These ion selective microelectrodes were proved that their own performance could be maintained for 16 days after making. NO3-N and NH4-N selective microelectrodes were also adapted to detect the continuous ion profiles of cilia media packed MLE (Modified Ludzack-Ettinger) process. And the monitored nitrate and ammonia ion profiles with the ion selective microelectrode were stable and well corresponded to the results with conventional ion chromatograph. However, the electric potential was unstable until 8 hr because of the unknown noise. The tip shape and performance of the ion selective microelectrode was stably kept over 2 days continuous monitoring.