• Title/Summary/Keyword: Continuous Measurement

Search Result 1,082, Processing Time 0.024 seconds

Statistical Analysis of Determining Optimal Monitoring Time Schedule for Crop Water Stress Index (CWSI) (작물 수분 스트레스 지수 산정을 위한 최적의 관측 간격과 시간에 대한 통계적 분석)

  • Choi, Yonghun;Kim, Minyoung;Oh, Woohyun;Cho, Junggun;Yun, Seokkyu;Lee, Sangbong;Kim, Youngjin;Jeon, Jonggil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.73-79
    • /
    • 2019
  • Continuous and tremendous data (canopy temperature and meteorological variables) are necessary to determine Crop Water Stress Index (CWSI). This study investigated the optimal monitoring time and interval of canopy temperature and meteorological variables (air temperature, relative humidity, solar radiation and wind speed) to determine CWSIs. The Nash-Sutcliffe model efficiency coefficient (NSE) was used to quantitatively describe the accuracy of sampling method depending upon various time intervals (t=5, 10, 15, 20, 30 and 60 minutes) and CWSIs per every minute were used as a reference. The NSE coefficient of wind speed was 0.516 at the sampling time of 60 minutes, while the ones of other meteorological variables and canopy temperature were greater than 0.8. The pattern of daily CWSIs increased from 8:00 am, reached the maximum value at 12:00 pm, then decreased after 2:00 pm. The statistical analysis showed that the data collection at 11:40 am produced the closest CWSI value to the daily average of CWSI, which indicates that just one time of measurement could be representative throughout the day. Overall, the findings of this study contributes to the economical and convenient method of quantifying CWSIs and irrigation management.

The Effect of Oral Health Education on PHP Index (구강보건교육이 구강환경관리 능력지수(PHP index)에 미치는 영향)

  • Shim, Youn-Soo;Kim, Hee-Won;Kim, Eun-Hee;An, So-Youn
    • Journal of the Korean Society of School Health
    • /
    • v.27 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of oral health education on adolescents. Methods: The subjects were middle school students in a health promoting school in Gunpo, Gyeonggi Province. Before giving the students oral health instruction, their modified Patient Hygiene Performance index (PHP index) was measured using disclosing solution. Then, the students were taught the right way to brush teeth (Rolling method) and use oral hygiene devices such as dental floss, tongue cleaner and interdental brush. Their modified PHP index was re-measured three days after and seven days after the education to evaluate the effect and persistency of oral health education. of the total 116 students, 48 students who completely filled out the questionnaire and participated in the whole process, photo shooting and three times of PHP index measurement, were included in the final analysis. Results: The students' modified PHP index significantly decreased three days after the education. However, the index slightly went back up seven days after the oral health education. Conclusion: Oral health education was effective in reducing dental plaque which remained after brushing. Continuous education about and constant motivation for oral hygiene turned out to be critical to maintain the impact of oral health education. Therefore, it is necessary to develop educational contents which can constantly motivate teenagers.

A Study on the Comparative Analysis of UHD Video Quality from Audience Viewpoint (시청자 관점에서의 UHD 콘텐츠 화질 비교 분석에 관한 연구)

  • Cho, Yong Suk;Min, Dong Chul;Choi, Seong Jhin
    • Journal of Broadcast Engineering
    • /
    • v.26 no.5
    • /
    • pp.621-642
    • /
    • 2021
  • In this paper, the subjective video quality assessment of the content quality was to examine by the assessors about the three content quality of HD, Up-scaling UHD, 4K UHD Native that is currently broadcasted. The comparative assessment was conducted using three types of TV sets, 55, 65, 75 inches, at a distance of 2.5 meters which is the distance of watching TV in general households. Among the participants who took part in the video quality evaluating experiment and the questionnaire survey, the answering data of the final 169 persons were adopted after removing the data of 4 persons who answered inadequately in the evaluation of the video quality. The effects of gender, preference of program genre, size of TV sets were analyzed statistically using SPSS 25.0 analysis package. In addition to these, the objective video quality assessment through the measuring instrument was performed, and compared with the results of subjective video quality assessment.

Evaluation of Diagnostic Reference Level in Interventional Procedures (인터벤션시술 진단참고수준 평가)

  • Kang, Byung-Sam;Park, Hyung-Shin
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.451-457
    • /
    • 2021
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure and patient radiation exposure is also increasing accordingly. In this study, we evaluated the patient dose of major interventional procedures nationwide and we established our Korean database. With these results, we tried to suggest the reference dose level for major interventional procedures. We evaluated patent dose data in the field of interventional radiology from foreign countries. Measurement of radiation dose exposure for 11 major interventional procedures was conducted using embedded DAP meters in 10,006 patients from 47 hospitals, and reference level of each interventional procedure was suggested. The DRLs of each intervenional procedure are as follows: TACE 206(Gy·cm2), AVF 12(Gy·cm2), LE intervention 43(Gy·cm2), TFCA 122(Gy·cm2), Cerebral aneurysm coil embolization 214(Gy·cm2), PTBD 22(Gy·cm2), Biliary stent 60(Gy·cm2), PCN 7(Gy·cm2), Hickman catheter 2.1(Gy·cm2), Chemoport 1.4(Gy·cm2), BAE 104(Gy·cm2). Compared with the previously established DRL in 2012, the radiation dose decreased in all 10 interventional procedures. In the future, continuous publicity and education on the radiation dose reduction will be needed.

The f0 distribution of Korean speakers in a spontaneous speech corpus

  • Yang, Byunggon
    • Phonetics and Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.31-37
    • /
    • 2021
  • The fundamental frequency, or f0, is an important acoustic measure in the prosody of human speech. The current study examined the f0 distribution of a corpus of spontaneous speech in order to provide normative data for Korean speakers. The corpus consists of 40 speakers talking freely about their daily activities and their personal views. Praat scripts were created to collect f0 values, and a majority of obvious errors were corrected manually by watching and listening to the f0 contour on a narrow-band spectrogram. Statistical analyses of the f0 distribution were conducted using R. The results showed that the f0 values of all the Korean speakers were right-skewed, with a pointy distribution. The speakers produced spontaneous speech within a frequency range of 274 Hz (from 65 Hz to 339 Hz), excluding statistical outliers. The mode of the total f0 data was 102 Hz. The female f0 range, with a bimodal distribution, appeared wider than that of the male group. Regression analyses based on age and f0 values yielded negligible R-squared values. As the mode of an individual speaker could be predicted from the median, either the median or mode could serve as a good reference for the individual f0 range. Finally, an analysis of the continuous f0 points of intonational phrases revealed that the initial and final segments of the phrases yielded several f0 measurement errors. From these results, we conclude that an examination of a spontaneous speech corpus can provide linguists with useful measures to generalize acoustic properties of f0 variability in a language by an individual or groups. Further studies would be desirable of the use of statistical measures to secure reliable f0 values of individual speakers.

Comparative Analysis of UV Protection Factor Measurement Methods for Each Country and Factors Affecting UV Protection Factor (각 국가별 자외선차단지수 측정법의 비교 분석 및 자외선차단지수에 영향을 주는 요인들)

  • Kim, Ye Jin;Nam, Gae Won
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.3
    • /
    • pp.193-203
    • /
    • 2021
  • Sunscreen is a product that blocks and scatters UV rays to protect them from UV rays. Domestic consumers generously invest in sunscreen, ranking first in the world in terms of sun care consumption per capita in 2019. Sunscreens are subject to a variety of factors, including regulations, ingredients, formulations, clinical trials, and product labeling, but are tightly controlled as product demand increases. In this study, various factors affecting the UV protection factor were investigated and analyzed. Preemptive measures such as continuous investigation are required so that various factors such as these do not become obstacles for domestic cosmetics companies to export, and to revitalize the export market with international competitiveness.

Preparation of highly hydrophobic PVDF hollow fiber composite membrane with lotus leaf-like surface and its desalination properties

  • Li, Hongbin;Zi, Xingchen;Shi, Wenying;Qin, Longwei;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.287-298
    • /
    • 2019
  • Lotus leaf has a special dual micro and nano surface structure which gives its highly hydrophobic surface characteristics and so-called self cleaning effect. In order to endow PVDF hollow fiber membrane with this special structure and improve the hydrophobicity of membrane surface, PVDF hollow fiber composite membranes was obtained through the immersion coating of poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) dilute solution on the outside surface of PVDF support membrane. The prepared PVDF composite membranes were used in the vacuum membrane distillation (VMD) for the desalination. The effects of PVDF-HFP dilute solution concentration in the dope solution and coating time on VMD separation performance was studied. Membranes were characterized by SEM, WCA measurement, porosity, and liquid entry pressure of water. VMD test was carried out using $35g{\cdot}L^{-1}$ NaCl aqueous solution as the feed solution at feed temperature of $30^{\circ}C$ and the permeate pressure of 31.3 kPa. The vapour flux reached a maximum when PVDF-HFP concentration in the dilute solution was 5 wt% and the coating time was kept in the range of 10-60 s. This was attributed to the well configuration of micro-nano rods which was similar with the dual micro-nano structure on the lotus leaf. Compared with the original PVDF membrane, the salt rejection can be well maintained which was greater than 99.99 % meanwhile permeation water conductivity was kept at a low value of $7-9{\mu}S{\cdot}cm^{-1}$ during the continuous testing for 360 h.

Implementation and Measurement of Protection Circuits for Step-down DC-DC Converter Using 0.18um CMOS Process (0.18um CMOS 공정을 이용한 강압형 DC-DC 컨버터 보호회로 구현 및 측정)

  • Song, Won-Ju;Song, Han-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.265-271
    • /
    • 2018
  • DC-DC buck converter is a critical building block in the power management integrated circuit (PMIC) architecture for the portable devices such as cellular phone, personal digital assistance (PDA) because of its power efficiency over a wide range of conversion ratio. To ensure a safe operation, avoid unexpected damages and enhance the reliability of the converter, fully-integrated protection circuits such as over voltage protection (OVP), under voltage lock out (UVLO), startup, and thermal shutdown (TSD) blocks are designed. In this paper, these three fully-integrated protection circuit blocks are proposed for use in the DC-DC buck converter. The buck converter with proposed protection blocks is operated with a switching frequency of 1 MHz in continuous conduction mode (CCM). In order to verify the proposed scheme, the buck converter has been designed using a 180 nm CMOS technology. The UVLO circuit is designed to track the input voltage and turns on/off the buck converter when the input voltage is higher/lower than 2.6 V, respectively. The OVP circuit blocks the buck converter's operation when the input voltage is over 3.3 V, thereby preventing the destruction of the devices inside the controller IC. The TSD circuit shuts down the converter's operation when the temperature is over $85^{\circ}C$. In order to verify the proposed scheme, these protection circuits were firstly verified through the simulation in SPICE. The proposed protection circuits were then fabricated and the measured results showed a good matching with the simulation results.

Establishment of Wave Information Network of Korea (WINK) (전국파랑관측자료 제공시스템 WINK 구축)

  • Jeong, Weon-Mu;Oh, Sang-Ho;Ryu, Kyung-Ho;Back, Jong-Dai;Choi, Il-Hoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.6
    • /
    • pp.326-336
    • /
    • 2018
  • Continuous measurement of nearshore waves around Korea over long period is very demanding to setup plans for prevention of disasters of port and coastal structures. In this respect, a new web-based system, termed as WINK, was established, which collects nearshore wave data from Korea Meteorological Agency (KMA), Korea Hydrographic and Oceanographic Agency (KHOA), and Ministry of Oceans and Fisheries (MOF) and provide them after quality control of the data. This paper describes technical aspects regarding collection and selection of the wave observation data, construction of wave hindcasting data, the methodology of quality control for the selected wave data, and overall process of building the web-based data providing system.

Smart Safety Helmet Using Arduino (아두이노를 이용한 스마트 안전모)

  • Lee, Dong-Gun;Kim, Won-Boem;Kim, Joong-Soo;Lim, Sang-Keun;Kong, Ki-Sok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.77-83
    • /
    • 2019
  • Major causes of industrial accidents include falls and gas leak. The existing safety helmet and smart device combination products are focused on convenience, so the functions to prevent such accidents are insufficient. We developed a smart helmet focusing on fall accident detection and gas leak detection. We also developed management system to manage workers efficiently. Its core function is to detect dangerous conditions of employees, to communicate with managers and to confirm the situations of workers. The effectiveness of the combustible gas measurement capability was verified through experiments. However, since a significant amount of power consumption is founded due to continuous operation of the board and the sensor, countermeasures such as replacing with a large capacity battery are required.