• 제목/요약/키워드: Continuous Fluid

검색결과 340건 처리시간 0.022초

The continuous-discontinuous Galerkin method applied to crack propagation

  • Forti, Tiago L.D.;Forti, Nadia C.S.;Santos, Fabio L.G.;Carnio, Marco A.
    • Computers and Concrete
    • /
    • 제23권4호
    • /
    • pp.235-243
    • /
    • 2019
  • The discontinuous Galerkin method (DGM) has become widely used as it possesses several qualities, such as a natural ability to dealing with discontinuities. DGM has its major success related to fluid mechanics. Its major importance is the ability to deal with discontinuities and still provide high order of approximation. That is an important advantage when simulating cracking propagation. No remeshing is necessary during the propagation, since the crack path follows the interface of elements. However, DGM comes with the drawback of an increased number of degrees of freedom when compared to the classical continuous finite element method. Thus, it seems a natural approach to combine them in the same simulation obtaining the advantages of both methods. This paper proposes the application of the combined continuous-discontinuous Galerkin method (CDGM) to crack propagation. An important engineering problem is the simulation of crack propagation in concrete structures. The problem is characterized by discontinuities that evolve throughout the domain. Crack propagation is simulated using CDGM. Discontinuous elements are placed in regions with discontinuities and continuous elements elsewhere. The cohesive zone model describes the fracture process zone where softening effects are expressed by cohesive zones in the interface of elements. Two numerical examples demonstrate the capacities of CDGM. In the first example, a plain concrete beam is submitted to a three-point bending test. Numerical results are compared to experimental data from the literature. The second example deals with a full-scale ground slab, comparing the CDGM results to numerical and experimental data from the literature.

펄스동전기법과 연속처리동전기법을 이용한 점토성-사질토의 탈수화 효율 비교 (Comparison of Improving Dewatering Process at Clay-Sandy Soil based on Pulse-Electrokinetic Technology and Continuous-Electrokinetic Technology)

  • 신상희
    • 한국지반환경공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.37-41
    • /
    • 2014
  • 펄스동전기법은 점토성-사질토에서 탈수화 공정을 효율적으로 진행하기 위해 제안되었다. 제안된 동전기법은 점토성-사질토에서 토양 안정성의 증진을 위해 전류 흐름에 따르는 유체의 이동에 의한 탈수화 공정을 진행하는 것이다. 제안된 동전기법의 성능을 확인하기 위해 제작된 샘플은 총 7일간에 점진적으로 압력을 증가시켜 30 psi($2.11kgf/cm^2$)의 최종압력으로 압축과정을 거쳐 완성되었다. 기존의 연속적인 처리와 펄스방식으로 처리하는 공정을 비교하여 각각의 특성을 관찰하였다. 각각의 테스트는 48시간 동안 3 V/cm의 전압 경사 조건으로 연속적인 처리공정과 48시간 동안 총 8시간씩 3회에 걸쳐 전기를 차단하는 펄스방식으로 진행하였다. 그 결과, 펄스방식의 효율이 연속처리방식의 효율과 비슷한 것으로 나타났고 펄스방식이 연속처리방식보다 전력소비가 약 50 % 감소로 그 경제성을 입증하였다.

평판핀이 부착된 증발기의 시뮬레이션 (Numerical Simulation of Plate Finned-Tubes Evaporator)

  • 손병진;민묘식;최상경
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.297-304
    • /
    • 1989
  • Development of a more satisfactory program of computing the performance on a multi-tube evaporator with continuous plate fins is attempted in this study. The fluid flow involving a change of phase make the flow properties and fluid friction factor of refrigerants, the heat transfer coefficients of refrigerant and air sides vary significantly. Taking such variations into account, a useful program is developed to predict the steady state performance of a multi-tube evaporator. The program was applied to an evaporator which has outside diameter of 10.05mm, inside diameter of 9.35mm, length of 5.4m and two rows arraied staggered. Then the variations of refrigerant quality, temperature, pressure, velocity, enthalpy, specific volume and air temperature, tube temperature were discussed. Satisfactory results were presented that the degree of superheat at the outlet side was $4.4^{\circ}C$ and the air temperature drop between the inlet and outlet of the air conditioner was $10^{\circ}C$.

  • PDF

순수유체와 다공성물질의 경계면에서 압력구배의 수치적 처리에 관하여 (On Numerical Treatment of Pressure Gradient at the Interface Between a Homogeneous Fluid and a Porous Medium)

  • 김인선;남진현;김찬중
    • 한국전산유체공학회지
    • /
    • 제4권3호
    • /
    • pp.28-34
    • /
    • 1999
  • The objective of this study is to present a numerical treatment of the pressure gradient when control volumes are sharing the interface between a homogeneous fluid and a porous medium. Two possible approaches, e.g. linear interpolation and extrapolation, are considered, and they are applied to the case of a steady and two-dimensional curved channel flow which is partially filled with a porous medium. It was found that the linear extrapolation produces a continuous velocity-field at the interface and thus is recommended. On the contrary, the linear interpolation entails a discontinuous velocity field at the interface, thereby warning its use in connection with the Brinkman-Forchheimer-extended Darcy flow model.

  • PDF

A Novel Viscosity Measurement Technique Using a Falling Ball Viscometer with a High-speed Camera

  • Jo, Won-Jin;Pak, Bock-Choon;Lee, Dong-Hwan
    • KSTLE International Journal
    • /
    • 제8권1호
    • /
    • pp.16-20
    • /
    • 2007
  • This study introduces a new approach to a falling ball viscometer by using a high speed motion camera to measure the viscosity of both Newtonian and non-Newtonian fluids from the velocity-time data. This method involves capturing continuous photographs of the entire falling motion of the ball as the ball accelerates from the rest to the terminal velocity state. The velocity of a falling ball was determined from the distance traversed by the ball by examining video tape frame by frame using the marked graduations on the surface of the cylinder. Each frame was pre-set at 0.01. Glycerin 74% was used for Newtonian solution, while aqueous solutions of Polyacrylamide and Carboxymethyl Cellulose were for non-Newtonian solutions. The experimental viscosity data were in good agreements with the results obtained from a rotating Brookfield viscometer.

"신간혜민어약원방(新刊惠民御藥院方).담음문(痰飮門)"에 대한 연구(硏究) (A Study on DamEum(Phlegm-fluid retention) in Shingan Hyemin Eoyakwonbang(新刊惠民御藥院方))

  • 엄동명;송지청;금경수
    • 대한한의학원전학회지
    • /
    • 제25권4호
    • /
    • pp.115-121
    • /
    • 2012
  • Objective : Yayaoyuanfang(御藥院方) is a prescription book, compiled by Xu Guozhen(許國楨) in 1267. Yayaoyuanfang was published in Chosun dynasty as named as Singan Hyemin Eoyakwonbang. Therefore, we have interests in what are the differences in those two books. Method : We try to analyze two texts' differences by physical bibliography and comparing contents only in DamEum. Result : Those differences are the name, order, matria medica, effects, medicine dose, how to use and medicine processing of prescriptions. Conclusion : There are several differences between Yayaoyuanfang and Singan Hyemin Eoyakwonbang. However, Singan Hyemin Eoyakwonbang is not a full text so far, we need continuous studies on Yayaoyuanfang and Singan Hyemin Eoyakwonbang.

Extraordinarily Long-Term Posttraumatic Cerebrospinal Fluid Fistula

  • Kim, Hyoung-Sub;Hur, Jin-Woo;Lee, Jong-Won;Lee, Hyun-Koo
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권5호
    • /
    • pp.403-405
    • /
    • 2007
  • Most posttraumatic cerebrospinal fluid (CSF) leakage is noticed by the patients with the first symptom, rhinorrhea. A 38-year-old woman presented with frequent clear continuous rhinorrhea and otorrhea for 5 years after basilar skull fracture. After this, meningitis was developed with subsequent CSF fistula. Her clinical symptom was improved by medical treatment. The dural defect and CSF leakage were not detected by computerized tomography (CT) cistemography. We report a rare case of persistent posttraumatic CSF fistula that continued for five years.

MR 유체 입자 속도 계측을 위한 디지털 홀로그래피 현미경 시스템의 개발 (Development of Digital Holographic Microscopy System for Measurements of Particle Velocities in MR Fluids)

  • ;강보선
    • 한국분무공학회지
    • /
    • 제21권2호
    • /
    • pp.88-94
    • /
    • 2016
  • In this study digital holographic microscopy system for measurements of 3-D velocities of particles in MR fluid is developed. Holograms are recorded using either a CCD camera with a double pulse laser or a high-speed camera with a continuous laser. To process recorded holograms, the correlation coefficient method is used for focal plane determination of particles. To remove noise and improve the quality of holograms and reconstructed images, a Wiener filter is adopted. The two-threshold and image segmentation methods are used for binary image transformation. For particle pairing, the match probability method is adopted. The developed system will be applied to measurements of the characteristics of unsteady 3-D particle velocities in MR fluids through the next stage of this study.

차량 능동현가시스템에 대한 강인 제어 해석 (Analysis of an Robust Control for a Vehicle Active Suspension System)

  • 김주용
    • 유공압시스템학회논문집
    • /
    • 제7권3호
    • /
    • pp.20-27
    • /
    • 2010
  • A vehicle suspension system performs two functions, the ride quality and the stability, which conflict with each other. An active suspension system has an external energy source, from which energy is always supplied to the system for continuous control of vehicle motion. Therefore, an active suspension system can have even more improved performance. Some control laws have been proposed for active suspension system, but in this paper, an optimal variable structure control(VSC) is proposed. The VSC method is well suited for a class of nonlinear system and can address the robustness issues to constant modelling errors and disturbances. This paper develops an optimal VSC controller and compares its performance to those of a passive suspension system and an active suspension system with an optimal controller. The transient and frequency responses are analyzed respectively.

  • PDF

입자 직경에 따른 물분무수 거동 특성에 관한 수치적 연구 (A Numerical Study of Water Mist Behavior According to Droplet Diameter-Size)

  • 이동찬;정우성;이철규;이덕희;장용준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.415-419
    • /
    • 2008
  • In this study, analysis of water mist behavior is performed using numerical simulation. Water mist is characterized by the droplet flow which is one of the multiphase flows and is discrete fluid droplets in continuous air. It is important to choose the proper diameter of droplet-size and the distance between the fire location and the position of water mist because it depends on the buoyancy from fire. Therefore the behavior of water mist with fire should be simulated by FLUENT, a commercial computational fluid dynamics(CFD) program, with Lagrangian discrete phase model. (DPM)

  • PDF