• 제목/요약/키워드: Continues cooling

검색결과 9건 처리시간 0.023초

북서태평양에서 3차원 수치모델을 이용한 해수면냉각에 미치는 태풍의 영향 (A Numerical Study of Sea Surface Cooling with the Passage of Typhoon Abby in the Northwestem Pacific)

  • 홍철훈
    • 한국수산과학회지
    • /
    • 제41권6호
    • /
    • pp.518-524
    • /
    • 2008
  • A three-dimensional primitive equation model (POM) and the buoy data (2900 N, 13500 E) from the Japan Meteorological Agency (JMA) for 27 typhoons between 1982 and 2000 are used to investigate the sea surface cooling (SSC) that accompanies typhoons in the northwestern Pacific. Observed sea surface temperatures (SSTs) rapidly drop 0.6 to 4.3 C, and SSC continues for several weeks after the passage of a typhoon. The model, which covers most of the northwestern Pacific ($24^{\circ}N$ to $52^{\circ}N$), simulated Typhoon Abby over the tropical Pacific, and successfully reproduces many observed features, including the pattern of SST decrease, inertial oscillations, etc. The model accurately simulated the SSC process, suggesting that the cyclonic eddy with a radius of a few hundred kilometers that trailed Typhoon Abby plays an important role in SSC.

등온열처리와 냉각에 따른 $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) 초전도체의 상변화 (Phase transformation of $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) Superconductor during Continuous Cooling and Isothermal Heat Treatment)

  • 오용택;신동찬;한영희;성태현;정년호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.42-45
    • /
    • 2003
  • The phase transformation of $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) was investigated using isothermal heat-treatment and continuous cooling in air. During continuous cooling, the $REBa_2Cu_3O_{7-x}$ (RE=123) superconducting phase with well-distributed $REBa_2Cu_3O_{7-x}$ (RE-211) was obtainde at a cooling rate of $0.001^{\circ}C$/s. Single phase RE-123 (Nd, Gd, Dy) was stable at $1050^{\circ}C$, $1050^{\circ}C$, and $950^{\circ}C$ during isothermal heat-treatment, respectively. Above these temperatures the RE-211 phase existed within the RE-123 grains. The RE-123, RE-211, $BaCu_2Od_2$, and CuO phases coexisted at $50^{\circ}C$ below the partial melting temperature for each respective rare-earth RE-123.

  • PDF

Experimental study on the consolidation of saturated silty clay subjected to cyclic thermal loading

  • Bai, Bing;Shi, Xiaoying
    • Geomechanics and Engineering
    • /
    • 제12권4호
    • /
    • pp.707-721
    • /
    • 2017
  • The objective of this paper is to experimentally study the consolidation of saturated silty clay subjected to repeated heating-cooling cycles using a modified temperature-controlled triaxial apparatus. Focus is placed on the influence of the water content, confining pressure, and magnitudes and number of thermal loading cycles. The experimental results show that the thermally induced pore pressure increases with increasing water content and magnitude of thermal loading in undrained conditions. After isothermal consolidation at an elevated temperature, the pore pressure continues to decrease and gradually falls below zero during undrained cooling, and the maximum negative pore pressure increases as the water content decreases or the magnitude of thermal loading increases. During isothermal consolidation at ambient temperature after one heating-cooling cycle, the pore pressure begins to rise due to water absorption and finally stabilizes at approximately zero. As the number of thermal loading cycles increases, the thermally induced pore pressure shows a degrading trend, which seems to be more apparent under a higher confining pressure. Overall, the specimens tested show an obvious volume reduction at the completion of a series of heating-cooling cycles, indicating a notable irreversible thermal consolidation deformation.

Al-Zn-Si 3원계 합금도금강판의 부식거동에 관한 연구 (A Study on the Corrosion Behavior by the Moisture on the Surface Layer of the Al-Zn-Si ternary alloys)

  • 김영호;이상래;정원섭
    • 한국표면공학회지
    • /
    • 제34권3호
    • /
    • pp.187-194
    • /
    • 2001
  • Galvalume sheet steel was developed recently, and is used widely in several fields. It has and had a good corrosion resistance in open atmosphere, but it has week corrosion resistance in the ambient surroundings of an airtight packing. Therefore, black patina was synthesized on the surface of Galvalume sheet steel. Corrosion by moisture on a Galvalume surface begins from edge of a droplet and proceeds to the center of droplet. It begins mainly on the interdendritic structure instead of dendritic structure. This suggests that corrosion by moisture occurs on the Zn shrinkage hole from rapid air cooling. In addition, the initial corrosion occurs by the local cell and continues by the oxygen concentration cell.

  • PDF

Transient characteristics of current lead losses for the large scale high-temperature superconducting rotating machine

  • Le, T.D.;Kim, J.H.;Park, S.I.;Kim, D.J.;Lee, H.G.;Yoon, Y.S.;Jo, Y.S.;Yoon, K.Y.;Kim, H.M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권4호
    • /
    • pp.62-65
    • /
    • 2014
  • To minimize most heat loss of current lead for high-temperature superconducting (HTS) rotating machine, the choice of conductor properties and lead geometry - such as length, cross section, and cooling surface area - are one of the various significant factors must be selected. Therefore, an optimal lead for large scale of HTS rotating machine has presented before. Not let up with these trends, this paper continues to improve of diminishing heat loss for HTS part according to different model. It also determines the simplification conditions for an evaluation of the main flux flow loss and eddy current loss transient characteristics during charging and discharging period.

착상조건하에서 평행 평판 열교환기의 열 및 물질전달 (Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition)

  • 이관수;이태희;김우승
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

해풍시작에 영향을 미치는 지형성 강풍현상에 대한 수치실험 (Numerical Experiments on the Terrain Following Strong Wind Phenomenon Effecting to the Onset of Sea Breeze)

  • 이화운;정우식
    • 한국지구과학회지
    • /
    • 제24권4호
    • /
    • pp.325-336
    • /
    • 2003
  • 관측지점의 위치를 살펴보면 해안으로부터 수영은 약 5m정도이고 해운대는 약 1km정도 떨어져 있다. 하지만 해운대에서의 해풍시작시간이 수영보다 빨리 나타난다. 따라서 국지순환모형인 LCM을 이용하여 수영과 해운대에서 해풍시작시간에 대한 지형의 효과를 수치모의 하였다. 이러한 현상은 야간의 복사냉각에 의해 형성된 흐름에 의한 것으로 분석되었는데, 도심지를 둘러싸고 있는 고지대의 경사면을 따라서 수렴된 공기가 가장 저지대인 수영지역으로 흘러가기 때문에 나타난 것으로 이러한 현상은 일출 후에도 나타난다. AWS자료를 분석한 결과, 수영에서 해운대에 비해 약 3배정도 강한 강풍현상이 나타났는데, 이는 수영지역이 야간공기의 유출구이기 때문이다. 이를 통해 지형조건이 해풍의 시작에 중요한 역할을 한다는 것을 알 수 있었다.

적외선 검출기용 맥동관 극저온 냉동기 기술개발 (Development of the Pulse Tube Cryocooler for Infrared Detector)

  • 염한길;박성제;홍용주;고준석;인세환;김효봉
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권4호
    • /
    • pp.241-248
    • /
    • 2015
  • 국내 사용되고 있는 적외선 검출기 냉각용 스털링 극저온 냉동기는 상당부분 수입에 의존하고 있으며, 높은 대당 가격, 제한적인 수명 및 내구성 부족으로 지속적인 극저온 냉동기 수요가 발생하고 있다. 그런데 적외선 검출기용 극저온 냉동기 기술은 국방, 우주관련 기술로 선진국의 기술이전이나 공동 개발이 매우 제한적이다. 본 연구를 통해 개발하고자 하는 맥동관 극저온 냉동기는 저온구동부의 기계적 피스톤을 가스피스톤으로 대체하고, 압축방식을 선형압축방식으로 바꿈으로써 낮은 진동, 높은 수명 및 내구성을 확보할 수 있다. 이를 통해 맥동관 냉동기의 기술수준을 선진국에 근접시키고, 독자적인 냉각형 적외선 검출기 설계 및 제작기술에 대한 기술을 확보하고자 한다.

고밀도 폴리에틸렌 융착부에 대한 단기간 파손 평가법 개발 - 한계하중 적용 - (Development of a Short-term Failure Assessment of High Density Polyethylene Pipe Welds - Application of the Limit Load Analysis -)

  • 류호완;한재준;김윤재;김종성;김정현;장창희
    • 대한기계학회논문집A
    • /
    • 제39권4호
    • /
    • pp.405-413
    • /
    • 2015
  • 최근 미국에서는 가동기간이 오래된 원전 매설배관에서 부식 및 침식에 의해 삼중수소 누설로 지하수가 오염되는 사례가 급증하고 있다. 따라서, 현재 원전 안전등급 매설배관으로 사용되고 있는 금속재료의 배관을 대신해서 부식 및 침식 등의 열화 손상에 대한 저항성이 우수한 고밀도 폴리에틸렌(HDPE) 배관을 ASME Code Class 3 안전계통 배관으로 사용하기 위한 연구가 수행되고 있다. 본 연구에서는 발전소 가동 중 매설배관에 가해질 수 있는 하중과 온도 범위를 바탕으로 HDPE 배관 융착부에 대한 인장 시험과 저속균열성장 (SCG) 시험을 수행하였다. 시험 결과로 얻은 SCG 시험편의 파단면을 분석하여 HDPE 재료의 파손 기구를 파악하였다. 이를 바탕으로 3D 유한요소 해석을 이용하여 균열이 있는 HDPE 재료가 버틸 수 있는 한계하중에 대한 검증을 수행하였다.