• Title/Summary/Keyword: Contamination source

Search Result 515, Processing Time 0.022 seconds

Cutting Characteristics of Plasma Source Son Implanted Tungsten Carbide Tool (플라즈마 이온주입에 의해 표면 개질한 초경공구의 가공특성)

  • Kang, Seong-Ki;Wang, Duck-Hyun;Kim, Won-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • In this research, the effects for surface Improvement of plasma ion implanted carbide endmill tools were observed by measuring cutting forces and tools wear affecting surface roughness in high speed cutting. From the 2nd ion mass analysis, the oxidation layer was found to be built up by sputtering. The residual gas contamination of oxygen was found to be contained impurities in nitrogen gas. The plasma implanted ion was found to be spreaded, especially the nitrogen was implanted up to 150nm depth as impressed voltage and ion implanting time. It is analyzed as bring surface improvement by spreading deeply forming oxidation on surface. The factors in Analysis of Variance(ANOVA) about mutuality cause reference of cutting force. The cutting force Fx is affected by the interaction of spindle rpm and federate, the cutting force Fy is influenced by spindle rpm and time injected ion, and cutting force Fz is affected by the interaction of impressed voltage and feedrate. Also, it was found that the cutting forces of implanted tools become lower and the surface roughness is improved by the effect of nitrogen according to the implantation.

Electron Donor Determination and Comparisons of Reaction Rates for Bioremediation of Nitrate Contaminated Groundwater (질산성 질소로 오염된 지하수의 생물복원을 위한 적정 전자공여체의 결정 및 반응속도 비교 연구)

  • Oa, Seongwook;Lee, Yoonhee;Kim, Geonha;Kim, Young
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.630-636
    • /
    • 2005
  • Groundwater contamination by nitrate exceeding water quality criteria (10 mg $NO_3{^-}-N/L$) occurs frequently. Fumarate, acetate, formate, lactate, propionate, ethanol, methane and hydrogen gas were evaluated for their nitrate removal efficiencies and removal rates for in situ bioremediation of nitrate contaminated groundwater. Denitrification rate for each substrate was in the order of: fumarate > hydrogen > formate/lactate > ethanol > propionate > methanol > acetate. Microcosm studies were performed with fumarate and acetate. When fumarate was used as a substrate, nitrate was removed 100 percent with rate of 0.66 mmol/day while conversion rate from nitrate to nitrogen gas or another by-product was 87 percent. 42 mg of fumarate was needed to remove 30 mg $NO_3{^-}-N/L$. When using acetate as carbon source, 31 percent of nitrate was removed during initial adjustment period. Among removed fraction, however, 83 percent of nitrate removed by cell growth. Overall nitrate removal rate was 0.37 mmol/day. Acetate showed longer lag time in consumption compared to that of nitrate, which implying that acetate would be better carbon source compared to fumarate as more amount was utilized for nitrate removal than cell growth.

Recent Development of Drinking Water Quality Standard and its Application (음용수질 기준과 관리방안)

  • 권숙표
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.83-94
    • /
    • 1992
  • Recently water demand is increasing as the industry prospers. The increase of water demand is followed by the increase of wastewater discharge which pollutes rivers and ground water extensively. These rivers, reservoirs and ground water are sources for drinking water and their contamination affects the quality of water supply and other potable water. In Korea there are 776 water treatment plants which supply drinking water from main rivers or reservoirs. Rivers are the biggest water source for drinking water is being contaminated, the innovation of treatment process is needed. The construction and operation of water supply facilities is under the control of the Ministry of Construction and the water supply offices of cities and provinces. However, drinking water quality is under the control of the bureau of sanitation in the Ministry of Health and Social Affairs. There are 33 items in drinking water quality standards of Korea. Trihalomethanes, Selenium, Diazinone and other three of pesticides have been included lately, The Ministry of Health and Social Affairs is planning to enhance. the level of $VOC_S$(Vola-tile Organic Compounds) standard. Drinking water quality standard is the goal to protect the quality of supply water and ground water. In order to protect the source water from domestic or industrial water, technological improvement and adequate investment should be urgently made. The ultimate goal of drinking water quality is safety and health of consumers. The more stringent the standard are, the better the water quality will be. As the drinking water quality standards become more stringent this year, various and positive solutions by the authorities concerned must be prepared.

  • PDF

Geochemical Dispersion of Cu, Pb, Zn, and Cd and Their Mode of Occurrences in Soils and Dusts in Changhang Smelter Area (장항제련소 지역 토양과 분진중의 Cu, Pb, Zn 및 Cd의 지구화학적 분산과 산출상태)

  • Kim, Ju-Yong;Chon, Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.175-185
    • /
    • 1993
  • Soils and dusts collected from Changhang smelter area were analyzed for Cu, Pb, Zn, and Cd in order to determine their dispersion pattern and mode of occurrences, and to investigate the pollution level of heavy metals such as Cu, Pb, Zn, and Cd by smelting activity. The soil pH of Changhang area is in the range of 3.7~8.8, and increased with increasing distance from the smelter site. The particles containing heavy metals are several tens of ${\mu}m$ in diameter, and have well crystal form. Samples collected near the smelter show similar particle properties in size, shape, and composition, which means that they could be originated from the same contamination source. Element couples of Cu, Pb, Zn, and Cd indicate high correlation with each other, which means that Cu, Pb, Zn, and Cd could be originated from the same point source of smelter. Heavy metal contents were decayed to background levels from 2.5 kilometer away from the smelter.

  • PDF

Contamination of Heavy Metals in Stream Sediments in the Vicinity of the Sambo Pb-Zn-Barite Mine (삼보 연-아연-중정석 광산 주변 하상퇴적물에서의 중금속 오염 연구)

  • Kim, Sang-Hyun;Chon, Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.26 no.2
    • /
    • pp.217-226
    • /
    • 1993
  • Stream sediment samples were collected in the vicinity of the Sambo Pb-Zn-barite mine in order to investigate dispersion patterns and pollution levels of heavy metals, and to find out their mode of occurrences. Those samples were analyzed for Cd, Cu, Pb, Zn, Fe, and Mn by using partial extraction and sequential extraction methods. Stream sediments of this studied area has been contaminated severely by Pb, Zn, and Cd. Dispersion patterns of heavy metals in those sediments are different according to their pollution source and sampling distance from the mine. The stream sediment pH is generally neutral in control area, and is slightly acidic in the lower part of tailing dam. The main pollution source of stream sediments was confirmed as tailing and mine drainage. Their pollution level depends mainly on inflowed water and distance from the mine. The tolerance index ranges from -0.9 to 0.7. The mode of occurrances of heavy metals in polluted stream sediment are identified as Fe-Mn oxides, organic bounded and carbonate-bounded compound which show high potential of bioavailablity.

  • PDF

Effect of Fuel Injection Timing on Nitrous Oxide Emission from Diesel Engine (디젤엔진에서 연료 분사시기가 아산화질소에 미치는 영향)

  • Yoo, Dong-Hoon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.106-112
    • /
    • 2014
  • The diesel engine, which has high compression ratio than other heat engines, has been using as the main power source of marine transport. Especially, since marine diesel engines offer better specific fuel consumption (SFC), it is environment-friendly compared to those used in other industries. However, attentio should be focused on emissions such as nitrous oxide ($N_2O$) which is generated from combustion of low-grade fuels. Because $N_2O$ in the atmosphere is very stable, the global warming potential (GWP) of $N_2O$ is 310 times as large as that of $CO_2$, and it becomes a source of secondary contamination after photo-degradation in the stratosphere. It has been hitherto noted on the $N_2O$ exhaust characteristics from stationary power plants and land transportations, but reports on $N_2O$ emission from the marine diesel engine are very limited. In this experimental study, a author investigated $N_2O$ emission characteristics by using changed diesel fuel components of nitrogen and sulfur concentration, assessed on the factors which affect $N_2O$ generation in combustion. The experimental results showed that $N_2O$ emission exhibited increasement with increasing of sulfur concentration in fuel. However, all kinds of nitrogen component additives used in experiment could not change $N_2O$ emission.

Contemporary organic contamination levels in digested sewage sludge from treatment plants in Korea: (2) Non-alkylated Polycyclic Aromatic Hydrocarbons (우리나라 하수 및 폐수 처리 슬러지의 다환방향족탄화수소의 함량)

  • Lee Kang-Young;Chung Chang-Soo;Kim Young-Il;Lee Hyun-Kyung;Hong Gi-Hoon
    • Journal of Environmental Science International
    • /
    • v.14 no.4
    • /
    • pp.413-425
    • /
    • 2005
  • The 16 priority PAHs (Polycyclic Aromatic Hydrocarbons) designated by US Environmental Protection Agency were analyzed for some digested sludges from wastewater treatment plants in Korea. PAHs are an important group of organic contaminants present in sewage sludge due to their persistence and toxic potential. PAHs were extracted from freeze-dried sludges using a methylene chloride-methanol (2:1) mixture in a soxhlet extractor. The extracts were cleaned-up by silica gel/alumina combination column and subsequently fed into gas chromatograph/mass spectrometer (GC/MS) for determining PAH contents. The sum of the 16 PAHs in the sewage sludge varied from 534.8 to $5754.5 {\cal}ug/{\cal}kg$, dry wt.. In the sewage sludge, phenanthrene appears as the most abundant PAHs, followed by naphthalene, pyrene, fluoranthene. Source of the investigated sewage sludges relatively predominated pyrogenic. PAHs levels of sewage sludges in Korea appeared to be lower than those in other countries.

Changes in Concentrations of Nutrients and Heavy Metals of Plants and Soils in Rain Garden Systems used for Non-point Source Pollution Management (비점오염원관리를 위한 레인가든에서 식물과 토양의 영양물질과 중금속 농도변화)

  • Kim, Chang-Soo;Sung, Ki-June
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.27-35
    • /
    • 2012
  • Recently, there has been increasing interest in the use of rain garden systems as environmentally friendly ecological infrastructures for controlling stormwater runoff and managing non-point source pollution and information for the contamination of soil and plants can be essential for sustainable rain garden management. In this study, four rain garden mesocosms, namely single species planting with Rhododendron lateritium, single species planting with Zoysia japonica, mixed planting with R. lateritium and Z. japonica, and control without plants, were tested to investigate the change in concentrations of nutrients (N and P) and heavy metals (Cd, Cu, Pb, and Ni) in the soil and plants used in the rain garden system. The presence of plants resulted in greater nutrient retention in soil and lower potential leaching from the system. All systems showed an increase in the heavy metal concentrations in soil. The concentrations of most heavy metals were found to be higher in the herbaceous plants (Z. japonica) than in the shrubs (R. lateritium). The belowground part (root) had higher heavy metal concentrations than the aboveground part (leaf) but also showed a potential increase in leaves, and hence, careful plant management should be considered during rain garden operation.

Effective Decontamination and Remediation After Elemental Mercury Exposure: A Case Report in the United States

  • Johnson-Arbor, Kelly;Schultz, Brian
    • Journal of Preventive Medicine and Public Health
    • /
    • v.54 no.5
    • /
    • pp.376-379
    • /
    • 2021
  • Elemental mercury exposure can result in significant toxicity. Source decontamination and remediation are often required after larger elemental mercury exposures, but the details of these processes are infrequently reported. In the case described herein, a 64-year-old woman and her husband were exposed to elemental mercury in their home after the husband purchased it online for the purpose of recreational barometer calibration. After the mercury reportedly spilled during the calibration process, a vacuum cleaner was used to decontaminate the affected surface; this led to extensive mercury contamination of the home. The couple was relocated from the home while remediation occurred over the course of several weeks. Vacuum cleaning of an elemental mercury spill can lead to extensive volatilization and recirculation of mercury vapor. For smaller mercury spills, careful removal of visible mercury beads by using an eyedropper, cardboard, and masking tape is recommended. Larger spills require professional decontamination and remediation and may necessitate involvement of governmental resources. Vacuum cleaning should not be used as an initial method of decontamination after elemental mercury exposure. Careful attention to source decontamination can reduce the emotional and financial costs associated with extensive remediation after elemental mercury exposure.

The Infrared Medium-deep Survey. VII. Optimal selection for faint quasars at z ~ 5 and preliminary results

  • Shin, Suhyun;Im, Myungshin;Kim, Yongjung;Hyun, Minhee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.75.1-75.1
    • /
    • 2019
  • The universe has been ionized in the post-reionization by several photon contributors. The dominant source to produce the hydrogen ionizing photons is not revealed so far. Faint quasars have been expected to generate UV photon budgets required to maintain ionization state of universe. Observational limits, however, hinder to discover them despite their higher number density than bright one. Consequently, the influence of faint quasars on post-reionization are not considered sufficiently. Therefore, a survey to find faint quasars at z ~ 5 is crucial to determine the main ionizing source in the post-reionization era. Deep images from the Hyper Suprime-Cam Subaru Strategic Program (HSC SSP) allow us to search for quasar swith low luminosities in the ELAIS-N1 field. J band information are obtained by the Infrared Medium-deep Survey (IMS) and the UKIRT Infrared Deep Sky Survey (UKIDSS) - Deep ExtragalacticSurvey (DXS). Faint quasar candidates were selected from several multi-band color cut criteria based on simulated quasars on color-color diagram. To choose the reliable candidates with possible Lyman break, we have performed medium-bands observations. Whether a candidate is a quasar or a dwarf star contamination was decided by results from chi-square minimization of quasar/dwarf model fitting. Spectroscopic follow-up observations confirm three quasars at z ~ 5. 100% spectral confirmation success rate implies that the medium-band observations effectively select faint quasars with strong Lyman alpha emission.

  • PDF