• Title/Summary/Keyword: Contamination source

Search Result 515, Processing Time 0.028 seconds

Investigation of Microbial Safety and Correlations Between the Level of Sanitary Indicator Bacteria and the Detection Ratio of Pathogens in Agricultural Water (농업용수의 미생물학적 안전성 조사 및 위생지표세균 농도와 병원성미생물 검출률과의 상관관계 분석)

  • Hwang, Injun;Lee, Tae Kwon;Park, Daesoo;Kim, Eunsun;Choi, Song-Yi;Hyun, Jeong-Eun;Rajalingam, Nagendran;Kim, Se-Ri;Cho, Min
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.248-259
    • /
    • 2021
  • BACKGROUND: Contaminated water was a major source of food-borne pathogens in various recent fresh produce-related outbreaks. This study was conducted to investigate the microbial contamination level and correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water by logistic regression analysis. METHODS AND RESULTS: Agricultural water was collected from 457 sites including surface water (n=300 sites) and groundwater (n=157 sites) in South Korea from 2018 to 2020. Sanitary indicator bacteria (total coliform, fecal coliform, and Escherichia coli) and food-borne pathogens (pathogenic E. coli, E. coli O157:H7, Salmonella spp., and Listeria monocytogenes) were analyzed. In surface water, the coliform, fecal coliform, and E. coli were 3.27±0.89 log CFU/100 mL, 1.90±1.19 log CFU/100 mL, and 1.39±1.26 log CFU/100 mL, respectively. For groundwater, three kinds of sanitary indicators ranged in the level from 0.09 - 0.57 log CFU/100 mL. Pathogenic E. coli, Salmonella and Listeria monocytogenes were detected from 3%-site, 1.5%- site, and 0.6%-site water samples, respectively. According to the results of correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens by logistic regression analysis, the probability of pathogen detection increased individually by 1.45 and 1.34 times as each total coliform and E. coli concentration increased by 1 log CFU/100mL. The accuracy of the model was 70.4%, and sensitivity and specificity were 81.5% and 51.7%, respectively. CONCLUSION(S): The results indicate the need to manage the microbial risk of agricultural water to enhance the safety of fresh produce. In addition, logistic regression analysis is useful to analyze the correlation between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water.

A Study on Photovoltaic Panel Monitoring Using Sentinel-1 InSAR Coherence (Sentinel-1 InSAR Coherence를 이용한 태양광전지 패널 모니터링 효율화 연구)

  • Yoon, Donghyeon;Lee, Moungjin;Lee, Seungkuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.233-243
    • /
    • 2021
  • Photovoltaic panels are hazardous electronic waste that has heavy metal as one of the hazardous components. Each year, hazardous electronic waste is increasing worldwide and every heavy rainfall exposes the photovoltaic panel to become the source of heavy metal soil contamination. the development needs a monitoring technology for this hazardous exposure. this research use relationships between SAR temporal baseline and coherence of Sentinel-1 satellite to detected photovoltaic panel. Also, the photovoltaic plant detection tested using the difference between that photovoltaic panel and the other difference surface of coherence. The author tested the photovoltaic panel and its environment to calculate differences in coherence relationships. As a result of the experiment, the coherence of the photovoltaic panel, which is assumed to be a permanent scatterer, shows a bias that is biased toward a median value of 0.53 with a distribution of 0.50 to 0.65. Therefore, further research is needed to improve errors that may occur during processing. Additionally, the author found that the change detection using a temporal baseline is possible as the rate of reduction of coherence of photovoltaic panels differs from those of artificial objects such as buildings. This result could be an efficient way to continuously monitor regardless of weather conditions, which was a limitation of the existing optical satellite image-based photovoltaic panel detection research and to understand the spatial distribution in situations such as photovoltaic panel loss.

A Study Practice of Infection Control for Dental Office and Dental Hygienist and Bacterial Contamination of Dental Office Surface (치과 의료기관 및 치과위생사의 감염관리 실천도와 진료실내의 표면 세균오염도에 대한 연구)

  • Yun, Kyoung-Ok;Bae, Sung-Suk;Choi, Young-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.511-519
    • /
    • 2019
  • The purpose of this study was to investigate the status of infection control in dental office and the degree of infection control practice of dental hygienists. A self-reported questionnaire was answered by 193 dental hygienists working in dental hospitals or dental clinics in Gyeonggi and Incheon areas. The number of bacteria was measured sample of surface dental unit chair shoulder backrests and light handles from 19 dental hospitals and 28 dental clinics. It was responded that impression or occlusion bodies were routinely disinfected in 52.6% of the dental hospitals and dental prosthesis were routinely disinfected in 46.4% in dental clinics. The dental hospital and clinics disinfect the surface each 26.3%, 25% after the patient treatment. The dental hospital and clinic were detected bacteria $5.02^*10\^3CFU/mL$, $1^*10\^4CFU/mL$, from dental unit chair backrest, respectively and $8.32^*10\^3CFU/mL$, $4.26^*10\^4CFU/mL$ from light handles, respectively. At the conclusion of this investigation, it can be kept from infection source in dental office is to make the right selection and use of the personal protective equipments and to improve the practice level by regular and active education. The same infection control practice should be done by institutionalizing and mandating infection control practice.

Microbial Community Structures Related to Arsenic Concentrations in Groundwater Occurring in Haman Area, South Korea (함안지역 지하수의 비소(As) 함량과 미생물 군집 특성과의 연관성 검토)

  • Kim, Dong-Hun;Moon, Sang-Ho;Ko, Kyung-Seok;Kim, Sunghyun
    • Economic and Environmental Geology
    • /
    • v.53 no.6
    • /
    • pp.655-666
    • /
    • 2020
  • This study evaluated the characteristics of arsenic production in groundwater through microbial community analysis of groundwater contaminated with high arsenic in Haman area. Groundwater in Haman area is contaminated with arsenic in the range of 0-757.2 ㎍/L, which represents the highest arsenic contamination concentration reported in Korea as natural groundwater pollution source. Of the total 200 samples, 29 samples (14.5%) showed higher arsenic concentration than that of 10 ㎍/L, which is the standard for drinking water quality, and 8 samples (4%) found in wells with 80-100 m depth were above 50 ㎍/L. In addition, seven wells with arsenic concentration more than 100 ㎍/L located in the northern part of Haman. As a result of microbial community analysis for high arsenic-contaminated groundwater, the microbial community compositions were significantly different between each sample, and Proteobacteria was the most dominant phyla with an average of 61.5%. At the genus level, the Gallinonella genus was predominant with about 12.8% proportion, followed by the Acinetobacter and Methermicoccus genus with about 7.8 and 7.3%, respectively. It is expected that high arsenic groundwater in the study area was caused by a complex reaction of geochemical characteristics and biogeochemical processes. Therefore, it is expected that the constructed information on geochemical characteristics and microbial communities through this study could be used to identify the origin of high arsenic groundwater and the development of its controlling technology.

Monitoring of some heavy metals in oriental animality medicines (동물성 생약에 함유되어 있는 몇 가지 중금속에 대한 실태 조사)

  • Baek, Sunyoung;Chung, Jaeyoen;Lee, Jihye;Park, Kyungsu;Kang, Inho;Kang, Sinjung;Kim, Yunje
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.201-209
    • /
    • 2009
  • Four heavy metals (Pb, Cd, As, and Hg) in 38 species (total 325 samples) of oriental animality medicines were monitored by inductively coupled plasma-mass spectrometry (ICP-MS) and automatic mercury analyzer (AMA). The detected concentration range of Pb, Cd, As was presented as $0.02{\mu}gkg^{-1}$ $(D.L){\sim}11.29mgkg^{-1}$, $0.01{\mu}gkg^{-1}$ $(D.L){\sim}2.50 mgkg^{-1}$, $0.12{\mu}gkg^{-1}$ $(D.L){\sim}5.27mgkg^{-1}$, respectively. In case of Hg, it the concentration range was $0.01{\sim}77.11mgkg^{-1}$ except one sample which exceeded detection limit. In all samples of Amydae Carapax and Gallnut, it was not detected over the maximum residue limits of metals. Pb is in charge of the greatest portion of contamination in 22 species of animality medicines, and in case of Hg, 54.46% of total samples were over the maximum residue limits. Therefore, environmental levels of Pb and Hg are needed to continue the researches and the studies for tracking pollution source are required.

A study on TOC monitoring and spatial distribution analysis using a spectrometer in rivers (하천에서의 분광측정기를 이용한 TOC 모니터링 및 공간분포 분석 연구)

  • Yoon, Soo Bin;Lee, Chang Hyun;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.815-822
    • /
    • 2023
  • Organic pollution is one of the most common forms of water contamination. Under the Water Quality Conservation Act, indicators for measuring organic substances include BOD, COD, and TOC. Analysis of BOD and COD is labor-intensive, and in the case of organic substances where biological decomposition is not feasible or toxic substances are present, the accuracy is often low. Therefore, the Ministry of Environment is shifting towards TOC-centric management. With advancements in sensor technology today, various parameters can be monitored using sensors. In this study, digital monitoring of river TOC using a spectrophotometer called Spectro::lyser V3 was conducted. Initially, experiments were carried out at the Andong River Experiment Center to assess the applicability of the measurement equipment. Subsequently, data collected at the confluence of the Nakdong River was analyzed for the spatial distribution of TOC using the Kriging technique. This research proposes the utilization of sensors for river TOC monitoring and spatial distribution analysis. Real-time monitoring of changes in river TOC concentration can serve as fundamental data for pollution monitoring and response. Sensor-based river monitoring offers advantages in terms of temporal resolution and real-time data acquisition. When various spatial information interpretation methods are applied, it is expected to contribute to diverse studies such as aquatic ecological health, river water source selection, and stratification analysis in the future.

Characteristics of Groundwater Contamination Caused by Seawater Intrusion and Agricultural Activity in Sacheon and Hadong Areas, Republic of Korea (해수침투와 농업활동에 의한 사천-하동 해안지역 지하수의 오염 특성)

  • Kim, Hyun-Ji;Hamm, Se-Yeong;Kim, Nam-Hoon;Cheong, Jae-Yeol;Lee, Jeong-Hwan;Jang, Sung
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.575-589
    • /
    • 2009
  • Groundwater has been extracted for irrigation in Sacheon-Hadong area, which is close to the South Sea. We analyzed chemical components of groundwater to examine the effects of seawater intrusion and agricultural activities in the study area. Most groundwater samples displayed the Na/Cl concentration ratios similar to that of seawater (0.55) with an increasing tendency of electrical conductivity ($227-7,910\;{\mu}S/cm$) towards the coast. In addition, statistical interpretation of the cumulative frequency curves of Cl and $HCO_3$ showed that 30.1% of the groundwater samples were highly affected by seawater intrusion. Groundwaters in the study area mostly belonged to the Ca-Cl and Na-Cl type, demonstrating that they were highly influenced by seawater intrusion and cation exchange. The result of oxygen-hydrogen isotope analysis demonstrated slightly higher $\delta^{18}O$ ((-8.53)-(-6.13)‰) and ${\delta}D$ ((-58.7)-(-43.7)‰) comparing to mean oxygen-hydrogen isotope ratios in Korea. As a result of nitrogen isotope analysis, the $\delta^{15}N-NO_3$ values ((-0.5)-(19.1)‰) indicate two major sources of nitrate pollution (organic nitrogen in soil and animal and human wastes) and mixed source of the two. However, denitrification may partly contribute as a source of nitrogen. According to factor analysis, four factors were identified among which factor 1 with an eigenvalue of 6.21 reflected the influence of seawater intrusion. Cluster analysis indicated the classification of groundwater into fresh, saline, and mixed ones.

Trace element Analysis and Source Assessment of Apartment Parking Lot Dust in Daegu, Korea (공동주택 주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Bae, Gun-Ho;Jung, Cheol-Su;Park, Kyu-Tae;Lee, Myoung-Sook;Shin, Dong-Chan;Kim, Yong-Hye;Yoon, Min-Hye;Han, Young-Jin;Choi, Hyuek;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.756-766
    • /
    • 2011
  • In order to investigate the degree of apartment parking lot dust contamination, total 72 samples of parking lot dust (36 from ground parking lots and 36 from the underground parking lots) were collected in Daegu city from the end of March to the early June 2010. The dust samples were sieved below $100{\mu}m$, and analysed by ICP for 14 elements after an acid extraction. Results obtained from the source assessment of trace element using enrichment factor showed that Fe, K, Mg, Mn, Na and V were influenced by natural sources, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources in both the ground parking lot and the underground parking lot. And results showed that Ca were influenced by natural sources in the ground parking lot, but influenced by anthropogenic sources in the underground parking lot. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Underground parking lot dust was more affected by anthropogenic sources and contaminated compared with the ground parking lot dust. Pollution index of heavy metals revealed that underground parking lot dust was 5.5 times more contaminated with heavy metal components than the ground parking lot dust. The results of correlation analysis among trace elements indicated that components in the ground parking lot were more correlated than those in the underground parking lot, and especially more correlated with natural sources-natural sources. Analysis for correlations between components and influencing factors in the underground parking lot showed that concentrations of heavy metals were higher with smaller number of parking spaces and no ventilation system, and older apartments in last paint and cleaning had relatively higher contents of heavy metals than those of recently painted and cleaned.

Trace Element Analysis and Source Assessment of Household Dust in Daegu, Korea (대구지역 일반주택의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Jung, Yeoun-Wook;Yoon, Ho-Suk;Kwak, Jin-Hee;Han, Jeong-Uk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.69-78
    • /
    • 2010
  • In order to investigate the degree of household dust contamination, 48 samples of household dust (24 from urban area and 24 from rural area) in Daegu city were collected in vacuum cleaner during January to February 2009. Samples were sieved below 100 ${\mu}m$, and 14 elements (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V, Zn) were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, and V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from urban anthropogenic sources. Household dust in urban area was more affected by anthropogenic sources compared with that of rural area. Pollution index of heavy metals revealed that urban area was 1.8 times more contaminated with heavy metal components than rural area. The correlation analysis among trace elements indicated that components were correlated with natural sources-natural sources (Al-Mg, Al-Mn, Fe-Mn) and natural sources-anthropogenic sources (Al-V, Fe-Cr, V-Mn) in both urban area and rural area. Trace element components of rural area were more correlated than those of urban area. Houses that use oil for heating fuel had relatively higher contents of heavy metals rather than those using gas or electricity for heating fuel. Houses with children also had higher contents of heavy metals. In addition, the age of houses was found to influence the heavy metal levels in household dusts, with older houses (>10years) having higher concentrations than newer houses (<10years) and houses located near the major road (<10 m) were found to have relatively higher heavy metal levels in household dust.

Geochemical and Isotopic Study of the Onjeongri Granite in the Northern Gyeongsang Basin, Korea : Comparison with Cretaceous to Tertiary Granitic Rocks in the Other Part of the Gyeongsang Basin and the Inner Zone of Southwest Japan (경상분지 북부에 분포하는 온정리 화강암에 대한 암석화학적, 동위원소 지구화학적 연구 : 경상분지 다른 지역과 서남 일본 내대에 분포하는 백악기-제 3기 화강암류와의 비교 고찰)

  • 정창식;권성택;김정민;장병욱
    • The Journal of the Petrological Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.77-97
    • /
    • 1998
  • We analyzed geochemical and radiogenic isotope data to investigate the genesis and source characteristics of the Onjeongri granite in the northern part of the Gyeongsang Basin. Field observation and K-Ar ages confirm late Cretaceous intrusion (ca. 87 Ma) of the Onjeongri granite. The hornblende geobarometery gives less than 2 kbar for the emplacement pressure of the Onjeongri granite. Geochemical and isotopic compositions suggest that the Onjeongri granite was formed in a relatively immature arc system. $SiO_2$ contents show a negative linear relationship with initial $^{87}Sr/^{86}Sr$ ratios, and an apparent positive correlation with $^{207}Pb/^{204}Pb$ ratios, suggesting an incomplete mixing or assimilation. However, the isotopic data known for any exposed rocks of the study area do not fit as an endmember, implying that the contaminant might reside in the lower crust. A review of published isotopic ages, geochemical, and Sr and Nd isotopic data for the Cretaceous to Tertiary granites in the Gyeongsang Basin indicates the followings. 1) Granitic magmatism in the Gyeongsang Basin were episodic. 2) Granitic rocks in the basin were derived from young (< 0.9 Ga) lower crust, and their isotopic signatures reflect heterogeneous source region. Geochemical and isotopic signatures of granitic rocks in the basin are difficult to explain by upper crustal contamination. 3) Granites in the Gyeongsang Basin have closely related to those in the San in Belt of the Inner Zone of Southwest Japan in terms of age, petrography, and isotopic and geochemical composition. 4) Sr-Nd isotopic signatures of the Onjeongri granite are relatively primitive compared with granitic rocks in the other parts of the Gyeongsang Basin and in the Inner Zone of Southwest Japan.

  • PDF