• Title/Summary/Keyword: Contamination source

Search Result 515, Processing Time 0.027 seconds

High-density Cultivation and Cryopreservation of Saccharomyces Hansen CBS5926 (Saccharomyces cerevisiae Hansen CBS5926의 고농도 배양 및 동결건조 보존)

  • Bang, Kyu-Ho;Kim, Gap-Jin;Oh, Deok-Hwan;Rhee, Young-Ha
    • Korean Journal of Microbiology
    • /
    • v.35 no.4
    • /
    • pp.302-306
    • /
    • 1999
  • Production of biomass by fed-batch culture of Saccharomyces cerevisiae Hansen CBS5926, which is used to treat intestinal disorders, was investigated using ethanol as the sole carbon source. Ethanol was a better carbon source than glucose for high cell density culture of the st-rain since it could decrease the frequency of contamination while increasing the efficiency and final productivity of the fermentation process. Under optimal conditions, 38 g/ℓ of dry cell weight with $2.2{\times}10^{9}$ cfu/㎖ of maximum viable cell count was achieved after 72h cultivation. Freeze-drying of the cultured yeast cells resulted in severe reduction of viability. Of the freeze-drying protectants tested, 20% sucrose and 30% lactose were most effective for the preservation of yeast cells with a viability level of 16.3%. A combination of skim milk and lactose with 20% sucrose(w/v) exerted no synergistic influence upo the viability of the cells during cryopreservation by freeze-drying.

  • PDF

Status of Water Quality and Future Plans in the Philippines (필리핀의 수질현황 및 미래 관리계획)

  • Gorme, Joan B.;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.89-103
    • /
    • 2009
  • The Philippines is abundant with rich natural resources such as water. Because of rapid urbanization in the country, most of the water bodies are polluted as a result of domestic, agricultural and industrial activities. The Environmental Management Bureau (EMB) is the main government arm responsible for monitoring and inspection of affected water bodies. Only water bodies with at least four sampling events during dry and wet seasons were included in the assessment of water bodies that passed the DAO 90-34 water quality criteria. Water bodies were monitored for dissolved oxygen (DO), biochemical oxygen demand (BOD), total suspended solids (TSS), and total dissolved solids (TDS), heavy metals, fecal coliform contamination and nitrates. High pollutant concentrations from domestic, agricultural, industrial and nonpoint sources were observed from monitoring events due to inadequate sewage services and treatment facilities in the country. The objective of this paper was to present and evaluate the quality of the water bodies in the Philippines.

  • PDF

Evaluation of Water Quality for the Han River Tributaries Using Multivariate Analysis (다변량 통계 분석기법을 이용한 한강수계 지천의 수질 평가)

  • Kim, Yo-Yong;Lee, Si-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.501-510
    • /
    • 2011
  • In this study, water pollution sources of 14 major tributaries of Han river and characteristics of water quality for each target streams were evaluated based on water quality data in 2007.1-2009.12 (14 data sets) using a statistical package, SPSS-17.0. Cluster analysis over time and space for each stream resulted in 4 groups for the spatial variations in which type and density of pollution sources in the basins showed the greatest impact on grouping. Moreover, cluster analysis for the time variation in which rainfall, temperature and eutrophication were shown to contribute to the clustering, produced 2 groups, from summer to fall (July-Oct.) and from winter to early summer (Nov.-June). Four factors were found as responsible for the data structure explaining 71-90% of the total variance of the data set depending on the streams and they were organic matter, nutrients, bacterial contamination. Factor analysis showed main factors (water pollutants) changed according to the season with different pattern for each stream. This study demonstrated that water quality of each stream could produce useful outcomes when factor and pollution source of basin were evaluated together.

Sterols as Indicators of Fecal Pollution in Sediments from Shellfish Farming Areas (Yeoja Bay and Gangjin Bay) of Korea (분변계 스테롤을 이용한 남해안 패류양식어장(여자만과 강진만)의 퇴적물내 분변오염도 평가)

  • Choi, Minkyu;Lee, In-Seok;Hwang, Dong-Woon;Kim, Hyung Chul;Kim, Ye-Jung;Kim, Sook-Yang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.4
    • /
    • pp.437-444
    • /
    • 2013
  • Eight fecal sterols were analyzed in surface sediments collected from shellfish farming areas in Yeoja Bay and Gangjin Bay, Korea, to evaluate sewage-derived fecal pollution. The concentrations of coprostanol, a good marker of sewage-derived organic contamination, in sediments were in the range of 10-530 ng/g-dry in Yeoja Bay, and 10-190 ng/g-dry in Gangjin Bay. Coprostanol levels were markedly higher in the inner bay than in the outer bay. These levels were lower than those reported in urbanized bays in Korea, however, they were comparable to levels in other shellfish farming areas including Gamak Bay. A multivariate analysis of the ratios of other sterols suggested that the sterols originated from sewage and plankton/benthos. Sewage was the dominant source at stations located close to the river mouth and wastewater treatment plant (WWTP) outfalls, and plankton/benthos was the primary source in the outer bay. These results suggest that management of point sources, e.g., WWTP as well as non-point sources, e.g., riverine inputs is important for improving the water quality in Yeoja Bay and Gangjin Bay.

Application of In Situ Measurement for Site Remediation and Final Status Survey of Decommissioning KRR Site

  • Hong, Sang Bum;Nam, Jong Soo;Choi, Yong Suk;Seo, Bum Kyoung;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.173-178
    • /
    • 2016
  • Background: In situ gamma spectrometry has been used to measure environmental radiation, assumptions are usually made about the depth distribution of the radionuclides of interest in the soil. The main limitation of in situ gamma spectrometry lies in determining the depth distribution of radionuclides. The objective of this study is to develop a method for subsurface characterization by in situ measurement. Materials and Methods: The peak to valley method based on the ratio of counting rate between the photoelectric peak and Compton region was applied to identify the depth distribution. The peak to valley method could be applied to establish the relation between the spectrally derived coefficients (Q) with relaxation mass per unit area (${\beta}$) for various depth distribution in soil. The in situ measurement results were verified by MCNP simulation and calculated correlation equation. In order to compare the depth distributions and contamination levels in decommissioning KRR site, in situ measurement and sampling results were compared. Results and Discussion: The in situ measurement results and MCNP simulation results show a good correlation for laboratory measurement. The simulation relationship between Q and source burial for the source layers have exponential relationship for a variety depth distributions. We applied the peak to valley method to contaminated decommissioning KRR site to determine a depth distribution and initial activity without sampling. The observed results has a good correlation, relative error between in situ measurement with sampling result is around 7% for depth distribution and 4% for initial activity. Conclusion: In this study, the vertical activity distribution and initial activity of $^{137}Cs$ could be identifying directly through in situ measurement. Therefore, the peak to valley method demonstrated good potential for assessment of the residual radioactivity for site remediation in decommissioning and contaminated site.

The advancing techniques and sputtering effects of oxide films fabricated by Stationary Plasma Thruster (SPT) with Ar and $O_2$ gases

  • Jung Cho;Yury Ermakov;Yoon, Ki-Hyun;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.216-216
    • /
    • 1999
  • The usage of a stationary plasma thruster (SPT) ion source, invented previously for space application in Russia, in experiments with surface modifications and film deposition systems is reported here. Plasma in the SPT is formed and accelerated in electric discharge taking place in the crossed axial electric and radial magnetic fields. Brief description of the construction of specific model of SPT used in the experiments is presented. With gas flow rate 39ml/min, ion current distributions at several distances from the source are obtained. These was equal to 1~3 mA/$\textrm{cm}^2$ within an ion beam ejection angle of $\pm$20$^{\circ}$with discharge voltage 160V for Ar as a working gas. Such an extremely high ion current density allows us to obtain the Ti metal films with deposition rate of $\AA$/sec by sputtering of Ti target. It is shown a possibility of using of reactive gases in SPT (O2 and N2) along with high purity inert gases used for cathode to prevent the latter contamination. It is shown the SPT can be operated at the discharge and accelerating boltages up to 600V. The results of presented experiments show high promises of the SPT in sputtering and surface modification systems for deposition of oxide thin films on Si or polymer substrates for semiconductor devices, optical coatings and metal corrosion barrier layers. Also, we have been tried to establish in application of the modeling expertise gained in electric and ionic propulsion to permit numerical simulation of additional processing systems. In this mechanism, it will be compared with conventional DC sputtering for film microstructure, chemical composition and crystallographic considerations.

  • PDF

Characteristics of Disinfection Performance in Water Treatment Plants with Introducing Treatment Technigue Requirement (정수 처리기술 기준 도입을 앞둔 전국 정수장의 소독능 관리 현황 및 특색)

  • Yeom, Cheolmin;Cho, Soonhaing;Jung, Haewoong;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.327-336
    • /
    • 2002
  • Disinfection process in water treatment plants (WTPs) is one of the most important step in order to inactivate waterborne disease. However, what is the necessary disinfection in WTPs was not properly established in Korea. This study was conducted to evaluate disinfection performance in nationwide water treatment plants (n=474). Disinfection requirement based on the SWTR (Surface Water Treatment Rule) of the U.S. (1-log Giardia removal) was chosen in estimating the compliance. The scope of unit process for evaluating disinfection performance includes postdisinfection process in clearwells, pipeline, and storage tank. The worst water quality condition in individual WTPs was applied for the disinfection performance evaluation. The major results are as follows. First, it was appeared that 184 WTPs (39 %) provided insufficient disinfection performance. Disinfection performance was significantly improved during past 2 years. The ratio of the number of WTPs providing insufficient disinfection performance in 1999 and 2001 was 78 % and 41 %, respectively. One of major factors for this improvement was due to the improvement of $T_{10}/T$ value in clearwell, as a result of modification of clearwell facility. Second, if disinfection criteria is 3-log Giardia inactivation at worst water quality condition, then 19 % of all WTPs can not meet this disinfection criteria. And if disinfection criteria is strengthened to 4-log Giardia inactivation, then 58 % of all WTPs can not meet this disinfection criteria. Since disinfection criteria is decided by contamination level of Giardia in source water, it also needs the investigation of Giardia occurrence in source water.

An Importance Analysis of Planning Factors for Constructing Environmental-Friendly Industrial Estate (환경친화적 산업단지 조성을 위한 계획요소의 중요도 분석)

  • Lee, Eun Yeob;Kim, Jung Kon;Lee, Hyun Ju
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.4
    • /
    • pp.1-11
    • /
    • 2012
  • This study prepared the list of planning components required for constructing environment-friendly industrial complex and grasped major environment-friendly planning components by measuring the importance per each planning component via the survey for specialists. As a result of measuring the importance of planning component according to each field for constructing environment-friendly industrial complex, it is indicated that important planning components in natural environment field are establishing complex location plan considering its configuration and slope, excluding projects for steep slope-land, establishing countermeasures for reducing contaminants per its source, and separated location of contamination industry around living space. In living environment field, proposed planning components having relatively high importance are separated location of pollution causing industry, establishing energy saving land use plan, linking with green way, circulation network plan, lowering noise level at roadside, plan for separating between pedestrian and vehicle, securing parking space, extending green park and proper location, installing green buffer zone, conserving and forming landscapes, land use for raising energy efficiency, and expansion of energy source. In case of ecological environment, core planning components such as conserving upper class of ecological naturality degree, conserving main habitat, and biotope forming plan are suggested. This study is limited to find out planning components for constructing environment-friendly physical environment of industrial complex which is a part of non-production process. The approach to solve environmental problem by linking spatially production process and non-production process. There is a need to conduct follow-up study to constructing technique for environment-friendly industrial complex considering production & nonproduction process afterward.

Epidemiological study for infection route of brucellosis in a infected dairy farms (Brucella 감영농장에서 감염경로의 역학적 연구)

  • 윤여백;김영진;김추철;노영선;권미순;김철민;임채웅
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.2
    • /
    • pp.159-164
    • /
    • 2004
  • A dairy farm that has been suffered continuously(more than 2 years) from brucellosis in Korea in spite of repeated legal test-and-slaughter was investigated the main source of infection in the farm. All cattle(22 milking cows, 44 heifers, 60 calves, 8 bull), dogs(3 mixed breed), feces from wild birds(3 samples), drinking water(3 sites), and soil in the paddocks(14 sites) inside the farm were examined with serological and/or bacteriological methods including specific DNA detection with PCR method. Brucella spp in the milk and blood were detected in 12/22 and 5/22 milking cows, respectively, although all of them were negative with conventional tube agglutination test. The number of serologically positive heifer was 15(15/44), but the isolation of Brucella spp was succeeded in the only 11(11/15) of them. Brucella were detected in vagina 1(1/11) and nasal(3/12) excretion in serologically positive heifers. All the three dogs were serologically positive, and Brucella spp were isolated from their blood. However, Brucella spp were not detected in the drinking water, soil in the paddocks, nor the feces of wild birds. The results suggest that milking cow secrete Brucella spp through milk, genital tract and nasal cavity, which are the major source of infection in this farm, The main infection route of Brucella spp is contact to contact with Brucella spp excreting animals rather than environmental contamination. The animals, living together with infected cow such as dogs, are the readily susceptible and are required to be examined for Brucella spp.

A study on application of eco-friendly follow-up process connected with livestock wastewater treatment plant using the upflow constructed wetland (가축분뇨처리시설과 연계한 상향류식 인공습지의 자연형 후속처리공정 적용방안에 관한 연구)

  • Choi, Hanna;Cho, Eunha;Kang, Hogeun;Park, Joohyun;Kang, Seonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.359-370
    • /
    • 2015
  • This study developed an up-flow wetland providing either an eco-friendly follow-up process of medium-sized public treatment facility for livestock manure or a non-point source pollution controller near livestock farms. The four bench-scale up-flow wetlands were operated with four different bed media sets. The removal efficiencies of the wetland effluent for CODCr, TN, TP, SS were 35.2 %, 29.5 %, 31.2 % and 52.2 % for set 1(Blank, without reed, with bio-ceramic), 40.6 %, 43.4 %, 42.2 % and 55.4 % for set 2(with bio-reed & without bio-ceramic), 45.2 %, 48.7 %, 46.6 % and 66.3 % for set 3(with bio-reed & bio-ceramic), 32.9 %, 27.3 %, 29.3 % and 54.1 % for Set 4(with reed & bio ceramic), respectively. The set 3 condition having a mixture of bio-reed and bio-ceramic showed the highest efficiency in the bench-scale evaluation. This study suggests a mixture of bio-reed and bio-ceramic as suitable bed media in the construction of artificial wetlands near livestock farms. Soils including the bed media were monitored during the evaluation for trace elements. Soil analysis results were satisfied with the Korean Soil Contamination Standard. This study showed that the up-flow constructed wetland was feasible to treat the effluent livestock wastewater treatment facility.