• 제목/요약/키워드: Contamination process

검색결과 744건 처리시간 0.032초

Interface Control to get Higher Efficiency in a-Si:H Solar Cell

  • Han, Seung-Hee;Kim, En-Kyeom;Park, Won-Woong;Moon, Sun-Woo;Kim, Kyung-Hun;Kim, Sung-Min
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.193-193
    • /
    • 2012
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is the most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. Single-chamber PECVD system for a-Si:H solar cell manufacturing has the advantage of lower initial investment and maintenance cost for the equipment. However, in single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of single-chamber PECVD system. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. In order to remove the deposited B inside of the plasma chamber during p-layer deposition, a high RF power was applied right after p-layer deposition with SiH4 gas off, which is then followed by i-layer, n-layer, and Ag top-electrode deposition without vacuum break. In addition to the p-i interface control, various interface control techniques such as FTO-glass pre-annealing in O2 environment to further reduce sheet resistance of FTO-glass, thin layer of TiO2 deposition to prevent H2 plasma reduction of FTO layer, and hydrogen plasma treatment prior to n-layer deposition, etc. were developed. The best initial solar cell efficiency using single-chamber PECVD system of 10.5% for test cell area of 0.2 $cm^2$ could be achieved by adopting various interface control methods.

  • PDF

김밥 제조공정에서의 미생물 오염도 평가 및 감마선 조사를 이용한 김밥의 보존안정성 향상 (Determination of Microbial Contamination in the Process of Rice Rolled in Dried Laver and Improvement of Shelf-life by Gamma Irradiation)

  • 김동호;송현파;김재경;김정옥;이현자;변명우
    • 한국식품영양과학회지
    • /
    • 제32권7호
    • /
    • pp.991-996
    • /
    • 2003
  • 김밥 원료 및 김밥 보존 중의 일반 호기성세균과 대장균군의 분포를 측정하고 감마선 조사에 의한 김밥의 위생성 및 보존성 개선 가능성을 살펴보았다. 김밥 원료 중 미생물 오염이 가장 큰 것은 김이었으며 비가열 채소인 오이의 오염가능성도 높았으나 실제로 김밥에 오염된 미생물의 대부분은 제조과정에서 환경으로부터 유입되었다. 김밥의 보존 중 일반세균의 생장은 밥과 계란에서 가장 높았으며 대장균군의 생장은 동물성 원료인 계란과 햄에서 현저하였다. 김밥의 감마선 조사에서 일반세균은 2kGy 이상의 선량에서 2∼4 log cycle 수준으로 감소하였으며 대장균군은 2 kGy 이상의 선량에서 대부분 사멸되었다. 감마선 조사선량에 따른 김밥의 관능평가 결과 3 kGy 조사구는 대조구에 비하여 관능적인 선호도가 현저히 낮았으며 2 kGy 조사구는 감마선 조사 직후 대조구에 비하여 다소 선호도가 낮았으나 15$^{\circ}C$에서 24시간 보존 후에도 안정적인 관능특성을 나타내었다. 따라서 김밥의 위생성 및 보존성 개선을 위하여 2 kGy의 감마선 조사가 적정 수준인 것으로 평가되었다.

고춧가루 제조.가공업체의 시설 및 공정별 미생물학적 오염도 평가 (Evaluation of the Level of Microbial Contamination in the Manufacturing and Processing Company of Red Pepper Powder)

  • 우혜임;김종배;최지희;김은혜;김동술;박건상;김은정;은종방;엄애선
    • 한국식품위생안전성학회지
    • /
    • 제27권4호
    • /
    • pp.427-431
    • /
    • 2012
  • 본 연구는 고춧가루 제조 가공업체를 대상으로 고춧가루의 원료 및 공정별, 제조시설 및 작업자 손, 제조환경에 대한 일반세균, 진균, 대장균군 및 병원성 미생물에 대한 미생물학적 위해도를 조사하였다. 제조공정별 시료에서는 분쇄 공정 후에 높은 오염도가 나타났으며 자외선 살균후에도 미생물 감소에 큰 효과가 나타나지는 않았다. 제조시설 및 작업자 손의 오염은 즉각적인 조치를 강구해야 할 정도의 오염도를 보여 제조시설 소독과 개인위생교육을 실시함으로써 교차오염에 주의할 필요가 있다. 제조환경 조사 결과, 모든 구역에서 오염도가 나타났으며, 특히 청결구역으로 지정되어 있는 내포장실에서 비교적 높은 수준의 오염도가 나타났다. 이에 따라 공기 순환을 통해 공중낙하균을 억제하는 등 청결한 위생관리를 위한 방법이 수립되어야 할 것으로 사료된다.

반도체 패키지용 Au Wire의 표면처리용 린스 성분에 따른 표면오염 비교 연구 (A Correlation Study on Surface Contamination of Semiconductor Packaging Au Wire by Components of Rinse)

  • 김하영;추연룡;임지수;박규식;김지원;강다희;라윤호;제갈석;윤창민
    • 접착 및 계면
    • /
    • 제25권2호
    • /
    • pp.63-68
    • /
    • 2024
  • 본 연구에서는 반도체 패키지용 와이어 본딩 공정에서 금(Au) wire의 표면처리에 적용되는 린스의 종류에 따른 Au wire의 오염 현상을 확인하고자 하였다. Au wire의 표면처리를 위해 실리콘(Si) 성분이 함유된 린스와 유기 계통으로만 이루어진 린스를 주로 사용하고 있으며, 실제 영향성을 확인하기 위해 두 종류의 1.0wt% 린스 용액으로 Au wire에 표면처리를 진행하였다. 이후, 반도체 공정에서 발생할 수 있는 Si 성분이 포함된 분진과의 반응성을 확인하기 위한 모사 실험을 진행하였다. 그 결과, optical microscopy(OM) 및 scanning electron microscopy(SEM) 분석을 통해 Si 성분이 함유된 린스로 표면처리한 Au wire의 경우 분진이 다량 흡착되었으며, 유기 계통으로만 이루어진 린스로 표면처리한 Au wire에는 소량의 분진이 흡착된 것을 확인하였다. 이는 Si 성분이 함유된 린스의 경우 상대적으로 극성을 띠기에, 주성분이 극성인 분진과 극성 상호작용을 일으키기 때문이다. 따라서 Si 성분이 존재하지 않는 린스를 사용하여 Au wire를 표면처리할 경우 분진에 의한 오염 현상이 감소하여 실제 와이어 본딩 공정에서 불량률을 낮추는 효과를 볼 수 있을 것으로 기대한다.

유기성 슬러지 반복 탈수에 의한 필터프레스 여과포 오염 특성 분석 및 초음파 세척 적용 평가 (Analysis of contamination characteristics of filter cloth in filter press by repeated dehydration of organic sludge and evaluation of ultrasonic cleaning application)

  • 김은주;정철진;김경우;송태규;한성국
    • 유기물자원화
    • /
    • 제32권2호
    • /
    • pp.15-25
    • /
    • 2024
  • 본 연구에서는 하수슬러지 필터프레스 공정에서 발생하는 오염 여과포에 대하여 가압수 및 초음파 세척에 대한 재생효율을 평가하였다. 이를 위하여 3톤 규모 하수슬러지 수열탄화물 처리 필터프레스로부터 오염된 여과포를 채취하였다. 먼저, 필터프레스 여과포의 오염 특성을 평가하였다. 오염 여과포의 위치에 따른 공기투과도와 단위질량을 측정하였으며, 새 여과포 측정값과 비교하였다. 다음으로 오염 여과포 전체 면적에 대하여 공기투과도 및 단위질량 분포를 지도화하여 오염 특성을 평가하였다. 마지막으로 오염 여과포를 대상으로 3 bar의 압력 세정 및 34, 76, 120, 168 kHz 주파수의 초음파 세척을 수행하였다. 이때, 여과포의 기공 오염 정도를 3단계로 나누어 세척효율을 평가하였다. 여과포 오염 비교 결과, 기공 오염은 여과물질이 지속적으로 투입, 압착되는 여과포 하부와 양측면 위주로 발생하였으며, 표면 오염은 전체면적에 걸쳐 고르게 나타났다. 가압 세척 결과, 공기투과도는 1.3-3.1%p 증가하였으며, 오염물질은 2.7-4.4% 제거되었다. 초음파 세척결과, 공기투과도는 12.5-61.5%p 증가하였으며 오염물질은 2.7-29.2% 제거되었다. 초음파 세척에서 주파수가 낮을수록 공기투과도 재생율과 오염물질 제거율이 우수하였다. 여과포의 기공 오염 정도가 클수록 초음파 세척 후 공기투과도 향상 및 오염물질 제거 효과가 우수하였다.

Effect of Spinal Cord Removal before or after Splitting and Washing on CNST Decontamination of Beef Carcasses

  • Lim, D.G.;Kim, D.H.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권11호
    • /
    • pp.1770-1776
    • /
    • 2007
  • Beef carcasses were examined to explore the effects of spinal cord removal and washing on central nervous system tissue (CNST) decontamination of the surface during the slaughtering process. A total of 15 carcasses were split by sawing centrally down the vertebral column and left sides of split carcasses were used for analysis. Samples were collected by swabbing the surface from 4 defined parts on the interior and 4 on the exterior of carcasses from the abattoir and analyzed using an ELISA-based test. The results showed that automatic and manual spray washing decreased CNST contamination, especially on the interior ventral parts of carcass surfaces (p<0.01), but did not decrease CNST on the interior dorsal parts. Increasing washing time to 60 s did not affect the reduction of CNST contamination. Samples following spinal cord removal prior to splitting showed lower calculated levels of "risk material" than the stated limit of detection (0.1%) of the ELISA kit on interior and exterior carcass parts (p<0.01). Therefore, spinal cord removal prior to splitting could be a very effective way to minimize CNST contamination of beef carcasses.

Phytochelatin synthase 발현을 통한 효모의 중금속 처리에 관한 연구 (Bioremediation of metal contamination groundwater by engineered yeasts expressing phytochelatin synthase)

  • 강소영;이원규;김재영;;김경웅
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.290-292
    • /
    • 2004
  • Heavy metal contamination has been increased in aqueous environments near many industrial facilities, such as metal plating facilities, mining operations, and tanneries. The soils in the vicinity of many military bases are also reported to be contaminated and pose a risk of groundwater and surface water contamination with heavy metals. The biological removal of metals through bioaccumulation has distinct advantages over conventional methods; the process rarely produces undesirable or deleterious chemical byproducts, it is highly efficient, easy to operate and cost-effective in the treatment of large volumes of wastewater containing toxic heavy metals. In addition, a recent development of molecular biology shed light on the enhancing the microorganism's natural remediation capability as well as improving the current biological treatment. In this study, characteristics of the cell growth and heavy metal accumulation by Saccharomyces cerevisiae strains expressing phytochelatin syntahse (PCS) gene were studied in batch cultures. The AtCRFI gene was demonstrated to confer substantial increases in metal tolerance in yeast. PCS-expressing cells tolerated more Cd$^{2+}$ than controls.

  • PDF

달성광산(達成鑛山) 주변지역(周邊地域)에서의 중금속오염(重金屬汚染)과 이의 제거방안(除去方案) (Heavy Metal Contamination and Process for Its Removal in the Vicinity of the Dalsung Cu-W Mine)

  • 김경웅;홍영국;김택남
    • 자원환경지질
    • /
    • 제29권1호
    • /
    • pp.57-63
    • /
    • 1996
  • The Dalsung copper-tungsten mine in the Taegu area, Korea was closed in 1975 and may be the sources of the heavy metal contamination in the tributary system and soil-plant system due to the mine drainage derived from the mine wastes and tailings. To examine the degree and extent of heavy metal contamination in the vicinity of Dalsung mine area, stream water and soil samples were taken and analyzed for heavy metals by ICP-AES and AAS. Highly contaminated soils are found near the Lower Tunnel No.0 ranging up to $1760{\mu}g/g$ As, $2060{\mu}g/g$ Cu, $1120{\mu}g/g$ Pb and 346 ${\mu}g/g$ Zn. From the results of the sequential extraction methods for the metal speciation, the heavy metals in soils may be derived from soil parent materials and acid mine drainage. With the processes for the heavy metal removal, most of the heavy metal ions in the acid mine drainage are removed by being exchanged with Ca ions held by the bentonite, hydroxyapatite and calcium hydoxide.

  • PDF

일본의 토양지하수오염 및 복원사례 (The Status of Soil and Groundwater Contamination in Japan and Case Studies of their Remediation)

  • Komai, Takeshi;Kawabe, Yoshishige
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.25-39
    • /
    • 2003
  • Risk and exposure assessment for subsurface environment is very important for both aspects of health and environmental protection as well as making decision of remedial goal for engineering activities. Exposure due to hazardous chemicals in the subsurface environment is essential to assess risk lev121 to individual person, especially from soil and groundwater environmental media. In this paper, the status of soil and groundwater contamination is presented to discuss on the problem for environmental risk assessment. The methodologies of fate and exposure models are also discussed by conducting the case studies of exposure assessment for heavy metals, organic compounds, and dioxin compounds. In addition, the structure of exposure models and available data for model calculation are examined to make clear more realistic exposure scenarios and the application to the practical environmental issues. Three kinds of advanced remediation techniques for soil and groundwater contamination are described in this paper, The most practical method for VOCs is the bio-remediation technique in which biological process due to consortium of microorganisms can be applied. For more effective remediation of soil contaminated by heavy metals we have adopted the soil flushing technique and clean-up system using electro-kinetic method. We have also developed the advanced techniques of geo-melting method for soil contaminated by DXNs and PCB compounds. These techniques are planed to introduce and to apply for a lot of contaminated sites in Japan.

  • PDF

수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향 (Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell)

  • 권준택;김준범
    • 한국수소및신에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.