• 제목/요약/키워드: Contamination of Surface

검색결과 933건 처리시간 0.029초

기름 유출로 인한 토양 및 지하수의 오염

  • Kim Dong-Jin;Yang Jae-Eui;Yu Jin-Yeol;Kim Hui-Gap;Kim Gi-Dong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.424-427
    • /
    • 2006
  • Soil contamination with petroleum oil around a military army was investigated. It showed that soils of a riverside highland, an entrance of the military army, and nearby roads were contaminated with total petroleum hydrocarbons (TPH) released from the military army to the depth of approximately 2 m. The measured concentrations were as high as 15,277 mg/kg. A wide range of soil in the riverside highland was contaminated by the movement of oil to the surface soil, which occurred with the vertical movement of groundwater table caused by the change of river water level and groundwater level. Spilled petroleum oil components were released into Wonju Stream by the increase of hydraulic conductivity and the groundwater flow.

  • PDF

Sampling and Analysis of Particles Generated in CSS-Mode of a Hard Disk Drive by Using a Particle Sampler (입자 샘플러를 이용한 하드디스크 CSS 동작 시 발생한 입자 샘플링 및 분석)

  • Lee Jae ho;Lee Dae Young;Kim Sang Yoon;Hwang Jung ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제29권5호
    • /
    • pp.599-608
    • /
    • 2005
  • Controlling particle contamination is important to increase storage capacity as the flying height of a slider in a hard disk drive decreases. Since precise detection and analysis of particles are primary steps of particle control in a HDD, many researchers have used sampling methods. In this paper, we newly designed a particle sampler and conducted performance evaluation of the sampler. Also, we conducted particle sampling from the HDD using the particle sampler and analysis of sampled particles by SEM and AES. Experimental results show that the particles generated by the slide-disk interaction mainly came from the disk surface.

Decontamination of Simulated Test Piece by Dry Ice Pellet Blasting (드라이아이스 펠렛 분사에 의한 모의 시편의 제염)

  • Shin Jin-Myeong;Park Jang-Jin;Yang Myung-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • 제19권2호
    • /
    • pp.30-36
    • /
    • 2004
  • Dry decontamination technique is required for maintaining nuclear material handling equipment contaminated with highly radioactive material in a hot cell. In order to determine the optimum blasting conditions of dry ice pellet blasting device, the basic experiments have been conducted on the simulated test specimens of four types of metals. The removal efficiency of test piece was evaluated by the XRF analysis and the change of the surface condition before and after blasting. The removal efficiency of cesium on loose contamination was 100% under blasting pressure; 3 kg/$cm^2$, blasting distance; 10 cm, blasting time: 10 sec. In case of fixed contamination, the removal efficiency of cesium was almost 96% under blasting pressure; 4kg/$cm^2$, blasting distance; 10 cm, blasting time; 30 sec.

Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition (환경에 따른 송전용 애자의 누설전류 분석)

  • Choi, In-Hyuk;Lee, Dong-Il;Kim, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF

Numerical Investigation of Contamination Particle's Trajectory in a Head/slider Disk Interface (헤드/디스크 인터페이스 내에서 오염 입자의 거동에 관한 수치적 연구)

  • Park, Hee-Sung;Hwang, Jung-Ho;Choa, Sung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제24권3호
    • /
    • pp.477-484
    • /
    • 2000
  • Microcontamination caused by particle deposition on the head disk interface threatens the reliability of hard disk drive. Design of slider rail to control contamination becomes an important issue in magnetic recording. In this paper, how particles adhere to the slider and the disk is examined. To investigate accumulation mechanism of the particles, trajectory of the particles in a slider/disk interface is simulated with considering various forces including drag force, gravitational force, Saffman lift force, and electrostatic force. It is found that the charged particles can easily adhere to the slider or disk surface, if an electric field exists between the slider and the disk. It is supposed that the vertical motion of the particles should be related with not only Saffman force but also electrostatic force.

An Experimental Study on the Measurement of Soot Contamination in a Diesel Engine Oil (디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰)

  • 공호성;조성용;윤의성;한흥구;정동윤
    • Tribology and Lubricants
    • /
    • 제19권5호
    • /
    • pp.251-258
    • /
    • 2003
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. The detector were evaluated in various ranges of contaminated oils by carbon black particles. It was found that the proposed detector could be well used to monitor the oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles onto the measurement surface was considered to be a critical problem of the detector. Effects of particle deposition on the interface was experimentally evaluated with the oil temperature and flow turbulence and discussed throughout this work.

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제25권6호
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

The Effect of the Non Soluble Industrial Dust on the Electrical Properties of Distribution Porcelain Suspension Insulators (비용해성 산업용 분진이 배전용 자기제 현수애자의 전기적 특성에 미치는 영향)

  • Kim, Chan-Young;Song, Il-Keun;Kim, Ju-Yong;Han, Jae-Hong;Kim, Dong-Myung;Lee, Byung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • 제50권4호
    • /
    • pp.182-189
    • /
    • 2001
  • In this paper, the distribution suspension porecelain insulators which had been used for long periods in the contaminated area were evaluated. The contaminated area is close to the sea and in the high density of industries. The heavily contaminated domestic and imported insulators were investigated by using electrical characteristics, such as power-frequency dry flashover voltage, power-frequency wet, flahover voltage, and leakage current. Also, these electrical results were compared with the contaminants on the surface. From these analysis, we found that the contamination from the industrial dust, only slightly decreased flashover voltage and increased leakage current. Therefore, the electrical properties of insulators used for 30 years in the area of coast and industrial complex were not much changed.

  • PDF

Investigation on DHF Application at Metal CMP Cleaning Process (Metal CMP 세정 공정에서 DHF 적용에 관한 연구)

  • 김남훈;김상용;김인표;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제16권7호
    • /
    • pp.569-572
    • /
    • 2003
  • In this study, we evaluated the dilute HF cleaning to reduce residual defects made by metal CMP process. The purpose of this test is to observe the existence of barrier metal damage during DHF cleaning on condition that it should not affect metal thin film reliability, so we will get rid of slurry residual particles as a main defect of the metal CMP process for the better yield. In-line defect data showed us that slurry residual particles were removed by DHF application. The HF rinse significantly reduced metal contamination levels and surface roughness. The best effect by additional oxide loss was discovered when Dilute HF condition is 10".

DC Langmuir Probe for Measurement of Space Plasma: A Brief Review

  • Oyama, Koichiro
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권3호
    • /
    • pp.167-180
    • /
    • 2015
  • Herein, we discuss the in situ measurement of the electron temperature in the ionosphere/plasmasphere by means of DC Langmuir probes. Major instruments which have been reported are a conventional DC Langmuir probe, whose probe voltage is swept; a pulsed probe, which uses pulsed bias voltage; a rectification probe, which uses sinusoidal signal; and a resonance cone probe, which uses radio wave propagation. The content reviews past observations made with the instruments above. We also discuss technical factors that should be taken into account for reliable measurement, such as problems related to the contamination of electrodes and the satellite surface. Finally, we discuss research topics to be studied in the near future.