• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.04 seconds

Physicochemical Characteristics and Analysis of Pollution Potential in the Sediments of the Rivers Flowing into the Saemangeum Reservoir (새만금호 유입 하천 하상 퇴적물의 물리화학적 특성과 오염도 분석)

  • Oh, Kyoung-Hee;Yu, Mi-Na;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.861-867
    • /
    • 2011
  • In order to understand the extent of contamination of the sediments on the Mankyoung and Dongjin Rivers flowing into the Saemangeum Reservoir, the concentrations of ignition loss (IL), COD, total nitrogen (T-N), total phosphorus (T-P), and heavy metals (As, Cd, Cr, Pb, Zn) were measured. The average concentrations of IL, COD, and T-P were 2.40 (${\pm}2.18$)%, 2.97 (${\pm}3.06$) mg/g sediment, 0.370 (${\pm}0.351$) mg/g sediment, respectively, showing the extent of contamination is not serious. However, the concentrations of these parameters in the samples taken in year 2009 were higher than those in year 2008, indicating the contamination of sediments goes on gradually. The concentrations of T-N were in the range of 0.59~13.11 mg/g sediment with variation of locations and seasons. It was determined that the T-N contamination is serious when the concentrations were compared with the dredging guidelines of sediments in the Korean freshwaters, indicating the countermeasures are required to maintain the water quality of the Saemangeum Reservoir. The concentrations of heavy metals except chromium did not exceed the worrisome level of soil contamination stipulated by the Soil Environment Conservation Act of Korea. The high concentration of chromium to be concerned in some samples from the upstream of Mankyoung River requires source analysis and countermeasure to control the contamination.

Persistent Organic Pollution and Arsenic Contamination in Asia Pacific Water: Case Study of Emerging Environmental Problems in Vietnam

  • Pham, Viet.H.
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.79-89
    • /
    • 2007
  • This paper provides a comprehensive overview of the present status of several environmental problems caused by emerging toxic substances such as persistent organic pollutants (POPs), endocrine disrupting chemicals (EDCs), and arsenic in various environmental media in Vietnam. Monitoring data reported during the 1990s demonstrated elevated contamination of DDTs in most of these compartments in Vietnam. Studies in frame of the Asia-Pacific Mussel Watch Program revealed that fish, mussels and resident birds from Vietnam contained higher concentrations of DDTs as compared to other countries in region, suggesting the role of Vietnamese environment as a significant emission source of DDT in the Southeast Asian region. The estimated dietary intakes of PCBs and DDTs for Vietnamese were relatively high among Asian developing countries, suggesting potential risk for humans posed by thesechemicals. Widespread contamination of some endocrine active compounds such as alkylphenols and phthalates was observed at various sites along the coasts of northern and middle Vietnam. The presence of significant source of bisphenol-A along Red River estuary was revealed with the concentrations comparable to those reported for developed nations. A case study on seasonal variation of alkylphenols and phthalates in surface water of river delta and estuary of north and middle Vietnam indicated the differences in distribution of these compounds between dry and rainy seasons. Higher concentrations of alkylphenols and phthalates were found in dry season in estuary; while the contrasting pattern was observed in the river delta, showing elevated residues in rainy season. This result suggests the different behavior of alkylphenols and phthalates in river delta and coastal environment. From ecotoxicological perspectives, concentrations of bis-phenol A and di(2-ethylhexyl)phthalates [DEHP] in surface water from some locations in Vietnam exceeded the guideline values for Ecotoxicological Effects and the Environmental Risk Limit, respectively, suggesting potential for toxic implications on aquatic wildlife. Widespread and elevated arsenic contamination was discovered inour recent surveys in groundwater in a large area of suburban areas of Hanoi city, the capital of Vietnam. The most recent investigation in 4 villages showed about more than 50 % of groundwater samples contained As concentrations exceeding 50 g/L (the WHO and Vietnamese standard). In particular, in Son Dong villages, 58 % of samples analyzed contained As concentrations higher than 200 g/L. Good correlations were found in As concentrations in water and hair and urine of peoples in corresponding families, suggesting the chronic exposure to As by people living in As-contaminated ground water areas. In Son Dong village, As levels in hair (mean: 1.7 mg/kg dry wt) and urine (g/g creatinine) exceeding the reference values recommended by WHO, suggesting potential for human risk posed by long term accumulation of As in human body. Future studies should be focused on the time trends of POPs and EDCs in biota in Vietnam in order to predict future trend of contamination and to reveal new clues for understanding possible toxic impacts on aquatic organisms. The issues of arsenic contamination in groundwater and their chronic toxic implications on human health should be systematically investigated in the future.

  • PDF

Effectiveness of Glove for the Prevention of Microbial Contamination during the Dental Clinical Practice (치과 임상실습에서의 장갑의 미생물 오염 차단 효과)

  • Jeong, Sun-Ju;Kim, Jung-In;Kim, Ji-Yeon;Ban, Se-Hee;Um, Ji-Young;Jeong, Moon-Jin;Lim, Do-Seon;Jeong, Soon-Jeong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.537-545
    • /
    • 2014
  • We conducted a study to access the effectiveness of glove and washing hands for the prevention of microbial contamination during the dental clinical practice. Microbial numbers at unwashed hands and gloves were $9.938{\time}10^3(CFU)/ml$, those at washed with soap were $9.44{\time}10^3CFU/ml$ And those at washed with a typical liquid soap including disinfectant, Dettol (Reckitt Benckiser, Slough, SL1 3UH, UK) were $6.58{\time}10^2CFU/ml$. In case of unwashed hand and hand washing with soap had similar microbial numbers and in case of hand washing with Dettol showed a rapid decrease of microbial number. Hand washing with Dettol was effective to prevent microbial contamination than hand washing with soap. Also microbial numbers in all case wearing gloves decreased. It showed effectiveness of gloves for prevention of microbial contamination. In addition to microbial numbers showed a tendency to increase from 3 hours on wearing gloves, the change of new gloves after 3 hours on wearing is necessary to minimize the danger of microbial contamination.

Improvement of a Dynamic Food Chain Model Considering the Influence of Radioactive Contamination of Foods by Rainfall During a Nuclear Emergency (원자력 사고 중 강우에 의한 음식물 오염영향을 고려한 역동학적 섭식경로모델 개선)

  • Hwang, Won-Tae;Kim, Eun-Han;Han, Moon-Hec;Choi, Yong-Ho;Lee, Han-Soo;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • For the consideration of the influence on radioactive contamination of foods due to rain during the release period of radionuclides in a nuclear accident, the previous dynamic food chain model was improved. Wet interception coefficients for the agricultural plants were derived as a function of radionuclide and rainfall amount, and mathematical formula of the model was also re-established. In the results for the same time-integrated radioactive concentrations on the ground, radioactive contamination of foods decreased greatly by rainfall, and it decreased dramatically according to increasing rainfall amount. It means that predictive contamination in foods using the previous dynamic food chain model, in which dry interception to the agricultural plants is only considered, can be overestimated. Among radionuclides considering in this study ($^{137}Cs,\;^{90}Sr,\;^{131}I$), influence of rainfall for food contamination was the most sensitive to $^{131}I$, and the least sensitive to $^{90}Sr$.

The effect of sterilization condition and UV-C irradiation on the reduction of contamination rate for oyster mushroom bottle culture (살균조건 및 UV-C 조사가 느타리버섯 병재배 오염율 감소에 미치는 영향)

  • Baek, Il-Sun;Chi, Jeong-Hyun;Jeoung, Yun-Kyeoung;Kim, Jeong-Han;Lim, Jae-Wook
    • Journal of Mushroom
    • /
    • v.13 no.3
    • /
    • pp.256-261
    • /
    • 2015
  • This study was conducted to reduce contamination ratio of oyster mushroom bottle cultivation. The optimal conditions of substrate sterilization for reducing of contamination ratio were at $121^{\circ}C$ for 90 min. In addition, UV-C irradiation is good for lower contamination ratio to continue over 6 hours at cooling and inoculation room after sterilization. The contamination ratio and density of microorganisms of substrate were showed 0% after sterilization at $121^{\circ}C$ for 90 min. Trichoderma sp., main pathogen of mushrooms, was detected from substrate after sterilized during 2 or 4 hours at $101^{\circ}C$ and $105^{\circ}C$, respectively. The amount of electricity used was the lowest at $121^{\circ}C$ for 90 min than that of other sterilization conditions. The UV-C irradiation treatment was used UV-C lamp(40 watts) in the inoculation room($56m^3$). The density of bacteria did not detected after UV-C irradiation for 6 hours. And the death ratio of bacteria and Trichoderma sp. was 99.9% after UV-C irradiation for 6 hours. However, in the same UV-C irradiation time, the death ration of Cladosporium sp. was 90.9%. Therefore, the death ratio of fungi was lower than that of bacteria at the same UV-C irradiation treatment.

Groundwater Contamination by Cation, Anion and Pesticides (지하수중 음이온, 양이온, 및 금속의 함량)

  • 김형석;정세영;최중명
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

Characteristics of Groundwater Pollution and Contaminant Attenuation at Waste Disposal Sites (폐기물 매립지 주변의 지하수 오염과 오염물질의 지연 특성)

  • 오석영;전효택
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.3 no.1
    • /
    • pp.37-49
    • /
    • 1996
  • The objectives of this study are to investigate the groundwater and surface water contamination, to interpret the attenuation mechanism of contaminant transport, and to find the appropriate contamination indicator. at the two big landfill sites : Nanjido Landfill and Hwasung Landfill. Leachate from the Nanjido, th, Hwasung and the Kimpo waste disposal sites is characterized by high temperature (31.7-40.1$^{\circ}C$), high electric conductivity (14,650-32,800 ${\mu}$S/cm), somewhat higher pH(7.58-8.45) and low Eh (-119.4-20.4 mV), and is enriched in both major (Na$^{+}$, K$^{+}$, Ca$^{2+}$, Mg$^{2+}$, HC $O_3$$^{-}$, Cl$^{-}$) and minor (Mn, Sr$^{2+}$, Ba$^{2+}$, Li$^{+}$, F$^{-}$, Br$^{-}$) ions. Municipal solid waste leachate and industrial waste leachate are effectively discriminated by the content of S $O_4$$^{2-}$, Fe, and heavy metals. The attenuation mechanism of each component was assessed using the chemical analysis. Cl-normalizing process, WATEQ4F simulation, and preceding flownet analysis. Based on the calculation of Contamination Factor, K, Na, Ca, Mg, B, Zn, HC $O_3$, Cl, F, Br and TOC are effective contamination indicators in the Nanjido landfill site, and K, Na, Ca, Mg, B, S $O_4$, HC $O_3$, Cl, F, Br and TOC in the Habsburg landfill site Particularly, TOC is the best contamination indicator in landfill sites influenced by sea water.

  • PDF

Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process (반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템)

  • Choi, Kwang-Min;Lee, Ji-Eun;Cho, Kwi-Young;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF

A STUDY ON THE EFFECT OF SALIVA CONTAMINATION ON THE BOND STRENGTH OF ONE-BOTTLE ADHESIVE SYSTEM (타액 오염이 One bottle 상아질 결합제의 전단결합강도에 미치는 영향에 관한 연구)

  • Jeon, Hyung-Joon;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.566-574
    • /
    • 2001
  • For decades it has been a clinically accepted requirement, in case of salivary contamination, to re-etch conditioned enamel and dentin to proceed with the adhesive technique. Only a few reports have been so far dealing with the potential of one-bottle adhesive system to bond even when applied after salivary contamination and without re-etching. The purpose of this study was to evaluate the influence of the salivary contamination on the shear bond strength of dentin. The results were as follows: 1. In group II, in which saliva contamination and washing occurred before applying of Prime & Bond NT showed high shear bond strength as in control group. In Group III and IV, in which the cured adhesive was contaminated with saliva, showed significantly lower mean bond strength, 2. Relating long resin tags of $70\sim120{\mu}m$ were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. And there were no differences between groups.

  • PDF