• Title/Summary/Keyword: Contaminated surface

Search Result 687, Processing Time 0.028 seconds

Detergency Performance Evaluation of Organic Adherent Pollutant by Modified Silicate-Based Antifouling Coating Material (변성 실리케이트계 방오성 코팅재의 유기성 피착 오염물질 세정성능 평가)

  • Chae, Woo-Byung;Seong, Dong-Yun;Kim, Cheun-Soo;Seo, Sang-Kyo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.275-278
    • /
    • 2012
  • This study try to finding the self-detergency performance of adherent pollutant on the mortar surface by using the developed silicate based antifouling coating material. Developed coating material coated on the surface of mortar test piece and after 30 minutes, over layed already coated mortar surface. After 7 days, the surface is polluted with crayons and oily magic marker. After 24 hours, contaminated area was wiped out the water. From the result of self-detergency performance test, it is concluded the developed material could be used as a detergent the contaminated concrete surface.

  • PDF

지하수 모니터링을 통한 오염물질(TEX)의 자연저감능 평가

  • Lee, Min-Hyo;Yoon, Jeong-Gi;Kim, Hyeok;Kim, Mun-Su;Lee, Gil-Cheol;Lee, Seok-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.179-182
    • /
    • 2002
  • The objective of this study was to evaluate petroleum hydrocarbon degradation processes governing natural attenuation at tile contaminated site and accomplished through conducting on investigation of degradation rate, capacity, and mechanism of the monitored natural attenuation. The monitoring results of the three years indicated that the concentrations of DO, nitrate, and sulfate in the contaminated area were significantly lower than these in the none-contaminated area. The results also showed a higher ferrous iron concentration, a lower redox potential and a neutral pH in the contaminated groundwater, suggesting that biodegradation of TEX is the major on-going process in the contaminated area. However, reduction of TEX in the groundwater was not only biodegradation but also dilution and reaeration during infiltration of uncotaminated surface and groudwater.

  • PDF

Remediation of Contaminated Ballast Gravels by Blasting Technology (Blasting에 의한 철도오염자갈의 재활용 연구)

  • Cho Young-Min;Park Duckshin;Choi Yoon;Lim Jong-Il;Lee Kyung-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.597-603
    • /
    • 2005
  • The remediation of railroad contaminated soil is gaining wide attention, recently. In railroad field, modification of diesel supply field, equipment of roll pad, FRP panel, and iron pannel under diesel locomotive storages are used for the prevention of contamination expansions. However, cheap and efficient remediation technology has not been suggested yet. In this study, the contaminated ballast was remediated by blasting technology. Because the contaminants mainly resides on the surface of ballast, blasting these contaminants make it available to recycle the ballast. We carried out the remediation of oil-contaminated ballasts using the blasting technology, and we could remediate them nicely. This technology is expected to be used for the cheap and quick remediation of contaminated ballast.

  • PDF

Physical remediation of ballast gravels contaminated by oil pollutants (도상자갈 표면 유류 오염물질의 물리적 제거방안 연구)

  • Cho, Young-Min;Lee, Jae-Young;Jung, Woo-Sung;Park, Duck-Shin;Kang, Hae-Sook;Kim, Hee-Man;Lim, Jong-Il
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1386-1391
    • /
    • 2007
  • The ballast gravels are often contaminated by various pollutants, like diesel fuel, lubricants, and heavy metals. Especially, the gravels near the switching are apt to be polluted by the lubricant. Because this lubricant can pollute the soil of track, the contaminated ballast gravels should be cleaned immediately. In this study, a physical desorption method was used to remove the oil contaminants from the surface of the ballast gravels. Thermosetting resin was used as a media for physical remediation of ballast gravels. The total petroleum hydrocarbon of the gravels was monitored over time. In addition, scanning electron microscopic images were obtained to observe the removal of the oily pollutants from the surface of the gravels.

  • PDF

A Study on Vortex Pair Interaction with Fluid Free Surface (자유표면에 작용하는 와동 현상에 대한 연구)

  • Sohn K.;Ryu H. K.;Kim K. H.;Kim S. W.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.67-72
    • /
    • 2002
  • Today, the research to examine a fact that interaction between the air and the fluid free surface affects the steady state flow and air. We proved the interaction between vortex pairs and free surface on each condition that is created by the end of delta wings. another purpose of this study is to investigate the effect of surface active material which can change the surface tension and we must consider when we refer to turbulent flow on surface tension. therefore, this research examined the growth process of vortex pairs on condition of clean, contaminated free surface and wall after we made vortex pairs through counter rotating flaps. The results of this study suggest that vortex pairs in clean free surface rise safely but the vortex pairs in contaminated free surface and rigid, no slip is made secondary vortex or rebounding. However the secondary vortex in rigid, no slip is stronger than before, and we can find the vortex shape which roll up more completely. However, these will disappear by the effect of wall.

  • PDF

The Removal Kinetics of Mn and Co from the Contaminated Solutions by Various Calcium Carbonate Surfaces (다양한 방해석 표면에 대한 Mn과 Co 흡착 기작)

  • H., Yoon;Ko, K.S.;Kim, S.J.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.219-222
    • /
    • 2004
  • Removal characteristics of Mn and Co was studied from the contaminated solutions via surface reaction with various calcium carbonate (calcite). Synthetic calcium carbonates which has different surface morphology as well as surface areas were prepared by a spontaneous precipitation method and used. Mn and Co removal behavior by the different solid surface demonstrate characteristic sorption behaviors depend on the type of calcite used, such as surface area or surface morphology. Calcium carbonate crystals (mostly calcite) which exhibit complicated surface morphology (c-type) shows strong sorption affinity for Mn and Co removal via sorption than on the a-type or b-type calcite crystals of less complicated surfaces. The applicability of two kinetic models, the pseudo-first-order kinetic equation and the Elovich kinetic model was examined on these sorption behavior. Elovich kinetic model was found more suitable to explain the very early stage adsorption kinetics, while the pseudo-first-order kinetic equation was successfully fitted for the adsorption kinetics after 50 hours.

  • PDF

Improvement of Water Quality for Contaminated Groundwater by $NO_3-N$ using Compression Packer in Boeun (압축패커를 이용한 보은지역의 질산성질소에 의한 오염지하수 수질개선)

  • Lee, Byeong-Dae;Yun, Uk;Yun, Seong-Taek;Cho, Heuy-Nam
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Most of contaminated groundwater in the study area was contaminated by $NO_3-N$ due to inflow of contaminated shallow surface groundwater inflow into groundwater well. Poor grouting and teared screen have increased contaminated shallow surface groundwater inflow into groundwater well. Contaminated shallow surface groundwater was inflowed into groundwater well throughout faults, joints and fracture zone of ESE-WNW, NNW, NW-SE and NS direction. The objective of this paper is to evaluate an improvement of water quality for contaminated groundwater by $NO_3-N$ using compression packer. For this study groundwater samples collected from 46 groundwater wells were analyzed to clarify $NO_3-N$ contents. Groundwater wells over 10 mg/L in $NO_3-N$ content is 9 wells showing 20% among total samples. $NO_3-N$ contents after compression packer installation showed 26~81% low value compared with before compression packer.

Method to Evaluate Fabric Contamination Due to Fine Dust (섬유소재의 미세먼지 오염도 평가 방법 개발에 관한 연구)

  • Hwang, So-Young;Kwon, Jin-Kyung;Kim, Young-Sil;Choi, Eun-Jin;Kim, Da-Jin;Kim, Min;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.86-91
    • /
    • 2021
  • Recently, functional clothes that can reduce deposition and/or penetration of fine dust have been developed. However, there are no methods to quantitatively evaluate the performance of these clothes. In this study, we developed a method to contaminate a fabric using fine dust and established an approach to quantitatively assess the degree of particle contamination on the fabric surface. Silicate powder was chosen as the particle to simulate fine dust because silicate particles are fluorescent under UV light; therefore, they can be distinguished from any color of non-fluorescent fabric surface. A camera with a high-resolution lens system was used to scan the surface of the contaminated fabric surface, and the degree of particle contamination of the fabric surface was analyzed in terms of the pixels corresponding to the area of the fabric surface contaminated by silicate particles. Finished or unfinished nylon fabrics as well as cotton fabrics were contaminated with silicate particles, and their surfaces were scanned using the established camera. The proposed assessment method was found to be useful for quantitatively comparing the degree of particle contamination of the fabrics.

Artificial contaminated test method and leakage current characteristics of EHV insulators (송전용 애자의 인공오손시험 기법과 누설전류 특성)

  • Choi, In-Huyk;Jung, Yoon-Hwan;Choi, Jang-Hyun;Lee, Dong-Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.386-391
    • /
    • 2004
  • To find out the reason of accident by being stained of insulators, this paper researched and analyzed the result of electrical characteristic test and field test of EHV insulator through artificial contaminated method. The best way to evaluate contaminated level of insulator surface is getting a contamination data by regional groups continually. But it is needed a lot of time and manpower. To overcome those difficulties, this research introduced ESDD(equivalent salt deposit density) measurement method which is adapted to the international codes of IEC and compared the relation between experimental test results which contaminated insulators by going through stain procedure and electrical measurement results.

  • PDF