• Title/Summary/Keyword: Contaminant

Search Result 1,027, Processing Time 0.03 seconds

Diffusive Estimation of the Conservative Contaminant in River Estuary (하구의 보존성 오염물질 확산 예측)

  • Yoon, Jong-Su;Shin, Chan-Ki;Hwang, Dong-Jin
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.47-57
    • /
    • 2008
  • This study was predicted the diffusion of the conservative contaminant using a two-dimensional hydraulic model. The research area is upper basin of Jakwang river where the possibility where the pollutant of vast quantity will flow is high. Using SMS model, we calculated two-dimensional stream flow. And using this result, predicted the conduct of the conservative contaminant by pollutant transfer diffusion calculation. And also we predicted flow and contaminant diffusion in the near estuary by constructed guide bank. As a result of study, pollutant effect scope of the conservative contaminant was predicted with the fact that will broaden because of interception by guide bank. As discharge was increased from the Jakwang river, The diffusion of the pollutant is accelerated, also the effect scope increases.

Modeling Bacteria Facilitated Contaminant Transport in Porous Media with Equilibrium Adsorption Relationships (평형 모델을 이용한 다공매질에서의 유동 세균에 의한 유기성 오염물의 가속이송)

  • 신항식;김승현
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.1
    • /
    • pp.14-21
    • /
    • 1995
  • Colloids such as exogenous biocolloids in a bioremediation operation can enhance the transport of contaminant in ground water by reducing retardation effects. Because of their colloidal size and favorable surface conditions in addition to their low density, bacteria can act as efficient contaminant carriers. When mobile bacteria are present in a subsurface environment, the system can be treated as consisting of three phases: water phase, bacterial phase, and the stationary solid matrix phase. In this work, a mathematical model based on mass balances is developed to describe the facilitated transport and fate of a contaminant in a porous medium. Bacterial partition between the bulk solution and the stationary solid matrix, and the contaminant partition among the three phases are represented by the equilibrium relationships. Solutions were obtained to provide estimates of contaminant and bacterial concentrations. A dimensionless analysis of the transport model was utilized to estimate model parameters from the experimental data. The model results matched with experimental data of Jenkins and Lion (1993). The presence of mobile bacteria enhances the contaminant transport. However, bacterial consumption of the contaminant which serves as a bacterial nutrient, can attenuate the contaminant concentration.

  • PDF

A Study on the Contaminant Transport Characteristics in Han River (한강 하류부에서의 오염물질의 거동특성 연구)

  • Kim, Hyeong-Il;Lee, Jong-Seol
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.1
    • /
    • pp.85-93
    • /
    • 1998
  • This study is to analyze and predict the contaminant transport based on the hydrauli characteristics using 2-dimensional finite element model. The dynamic wate quality model. RMA-4. is used to predict the contaminant transport using the hydrulic characteristics obtained from RMA-2v model. The study region is from downstream of Cham-sil weir to upstream of Shin-Kok weir. From the results of contaminant transport analysis. it is shown that the variations of discharge and velocity give quite large effect to the transport and dispersion of contaminant material. and that the water qualities of Joong-Rang and Tan streams play an important role to the downstream also. when the incidental contaminant accident occurs and contaminant material moves to the downstream. it is resulted the decreasing of the maximum COD and the increasing of the duration time to be affected by contaminant. Finally. 2-dimensional analysis is required in the case of large river like Han River. since the large difference of contaminant concentration has been investigated in the left and right bank.

  • PDF

Slip Resistance of Contaminants on the Floor for Variation of Viscosity (점도변화에 따른 바닥 오염물질의 미끄러짐 저항 특성)

  • Park, Jae-Suk;Oh, Whan-Sup
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.185-189
    • /
    • 2012
  • While there is no standards on slip risk for contaminants on surface, glycerol is described in standard contaminant for measuring coefficient of friction(COF) and slip resistance such as ISO 13287. But that is just used to measure the slip resistance of surface materials and shoes not to evaluate the contaminant materials. Therefore the objective of this study was to find out the relationship between standard contaminant and the contaminants used usually at the workplaces. For this, some measurement criteria were acquired from the analysis based on biomechanics and kinetics of human gait during slips. The slip resistance according to viscosity of the contaminants was measured applying the criteria and slip probability was determined by the gait analysis. Some factors which should be considered when measuring the slip resistance were identified. The velocity, acceleration, contact time and contact pressure should be 1 m/sec, 10 $m/sec^2$, 350 kPa and less than 0.5sec respectively. The variation of viscosity according to temperature for working oils was different from that of standard contaminant. The static coefficient of friction (SCOF) of working oils was almost 0.5 times as large as the SCOF of standard contaminant. So it was assumed to be difficult to compare the contaminants at the workplaces with the glycerol as a standard contaminant for estimating the slip risk.

Development of a Theoretical Model for Predicting Contaminant Concentrations in a Multi-zone Work Environment (다구획 작업환경에서의 오염농도 예측을 위한 이론적 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.4
    • /
    • pp.185-192
    • /
    • 2011
  • To predict contaminant concentrations within a multi-zone work environment, an air quality model in the work environment was developed. To do this, airflow equations on the basis of orifice equation were solved by using the Conte and De Boor scheme, and then equations for the conservation of mass on contaminant were solved by using the fourth-order Runge-Kutta algorithm. To validate the accuracy of simulated results, this model was applied to the controlled environment chamber that had been tested in 1998 by Chung KC. The comparison of predicted concentrations by this study with measured concentrations by the Chung KC indicated that the average deviations were 2.66, 3.35, and 3.15% for zone 1, zone 2, and zone 3, respectively. Also, this model was applied to a working plant with four zones. Thus, the results of contaminant concentration versus time were predicted according to the schedule of the openings operation, and case studies were done for four cases of the openings operation to investigate the interaction of airflow and contaminant concentration. The results indicated that opening operation schedules had a significant effect on contaminant removal efficiency. Therefore, this model might be able to apply for the design of ventilation schedules to control contaminants optimally.

A Prediction of the Indoor Contaminant diffusion using Network Simulation (시뮬레이션을 통한 실내 오염물질 확산의 예측 방법)

  • Kang, Ki-Nam;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.311-318
    • /
    • 2006
  • CFD simulation is a tool very useful to predict the generation and absorption of the contaminant from the construction materials for the single room condition. However, there is a limit in multi-room simulation for analyzing air movement and contaminant concentration at the condition that the door of each room was closed. A lot of network simulation tool were developed which can used to analyze the mass transfer and contaminant concentration as results in the multi-room condition. However, existing network simulation method was not able to analyze the change of the heating and cooling load with the ventilation as though the change of the indoor air-pollution density was predictable. In this study, new approach to predict heating/cooling load and indoor contaminant concentration will be reviewed. New indoor contaminant concentration module reviewed in this study wad coupled with existing ESP-r network simulation method. The validity of new approach will be analysed for comparison the results of simulation and field measurement results.

  • PDF

Long Term Trend and Stability of Contaminant Sources of Finished Landfill (사용종료 매립장 오염원의 장기 변화 및 안정성)

  • 장연수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.12a
    • /
    • pp.1-40
    • /
    • 1996
  • In order to determine the proper treatment of the finished landfill, it is important to predict the trend and stability of the major sources of contaminant in the landfill. In this paper the fate of contaminant sources in the landfill is studied from various literatures by grouping the contaminants into waste, leachate, and landfill gas. One example site referred is Nanji landfill which is one of the representative finished landfills in our country and the trend of contaminant sources in this landfill at current stage is discussed.

  • PDF

Effect of Colloids on Contaminant Transport in Riverbank Filtration (강변여과에서 콜로이드 물질이 오염물 거동에 미치는 영향)

  • Kim, Dae-Hwan;Lee, Sang-Il;Yoo, Sang-Yeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1398-1402
    • /
    • 2005
  • Riverbank filtration is a natural process using alluvial aquifers to remove contaminants and pathogens in river water for the production of drinking water. In riverbank filtration, the understanding of contaminant transport is an important task for the production of high quality drinking water. This study investigates the transport behavior of hydrophobic organic contaminants when colloids (dissolved organic matter and bacteria) are present in the aquifer. A mathematical model for the transport of contaminants is developed and solved numerically for various situations. Results show that in the riverbank filtration the presence of DOM and bacteria enhances the mobility of contaminant significantly. Sensitivity analysis indicates that the distribution of the total aqueous Phase contaminant is significantly affected by distribution coefficients which account for affinity of solid or colloidal Phase to contaminant.

  • PDF

Image Analysis: A Novel Technique to Determine the Efficiency of Wiping Cloths

  • Lee Jae-Hyung;Kim Seong-Hun;Oh Kyung-Wha
    • Fibers and Polymers
    • /
    • v.7 no.1
    • /
    • pp.73-78
    • /
    • 2006
  • The ability to absorb liquid and the dust removal performance are important factors for wiping cloths used to remove contaminants. We have developed a method that can determine the contaminant removal performance of wiping cloths. In the gravimetric method, experimental errors are unavoidable because the contaminant plate is much heavier than the contaminant material. However, we used image analysis to reduce the experimental errors, and did not use the heavy contaminant plate. The correlation coefficient between the image. analysis and the gravimetric methods was very high, at R=0.97, with a significance level of 95%. From the correlation analysis and empirical data, the image analysis method is a useful tool for measuring wiping efficiency. The wiping efficiency measured using image analysis has a close relationship to the wiping speed, viscosity of the contaminant, and wiping pressure, at the significance level of 95%.

A Study on Initial Control Performance of the Adsorption Protector for Construction Surface about Contaminant (흡착보양재 적용에 따른 실내 오염물질 초기제어 성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.229-235
    • /
    • 2009
  • In a domestic construction field, floor surface must be covered not to be scratched and polluted by protector until resident comes in. However this protector restricts the contaminant to leave from floor surface. So when the protector is removed, much contaminant is emitted from the floor surface to inside and makes a bad influence on the indoor air quality, In this research, it will be tested the reduction performance of contaminant between a normal protector and a contaminant absorption protector using charcoal powder.