• 제목/요약/키워드: Contaminant

검색결과 1,030건 처리시간 0.032초

하구의 보존성 오염물질 확산 예측 (Diffusive Estimation of the Conservative Contaminant in River Estuary)

  • 윤종수;신찬기;황동진
    • 환경위생공학
    • /
    • 제23권3호
    • /
    • pp.47-57
    • /
    • 2008
  • This study was predicted the diffusion of the conservative contaminant using a two-dimensional hydraulic model. The research area is upper basin of Jakwang river where the possibility where the pollutant of vast quantity will flow is high. Using SMS model, we calculated two-dimensional stream flow. And using this result, predicted the conduct of the conservative contaminant by pollutant transfer diffusion calculation. And also we predicted flow and contaminant diffusion in the near estuary by constructed guide bank. As a result of study, pollutant effect scope of the conservative contaminant was predicted with the fact that will broaden because of interception by guide bank. As discharge was increased from the Jakwang river, The diffusion of the pollutant is accelerated, also the effect scope increases.

평형 모델을 이용한 다공매질에서의 유동 세균에 의한 유기성 오염물의 가속이송 (Modeling Bacteria Facilitated Contaminant Transport in Porous Media with Equilibrium Adsorption Relationships)

  • 신항식;김승현
    • 대한지하수환경학회지
    • /
    • 제2권1호
    • /
    • pp.14-21
    • /
    • 1995
  • 지하수에 콜로이드가 있을 경우 지체계수 감소로인한 오염물의 가속이송이 일어난다. 세균은 콜로이드 크기이며, 비중이 물과 비슷하고. 또 특유의 표면조건으로 인하여 오염물을 가속이송시킬 수 있다. 유동 세균이 지하수에 있으면 그 system 은 액상, 고상, 그리고 입상의 3 상 (phase) 으로 해석되어야 한다. 본 연구에서는 물질수지에 기초한 수학적 모델을 개발하여 다공매질에서의 오염물의 이동을 예측했다. 세균과 오염물의 각 상사이의 분배는 평형분배 모델을 이용했다. 모델결과를 일반화하기 위하여 무차원화 기법이 사용되었다. 모델의 해는 수치해법이 사용되었고, 문헌상의 실험결과와 비교되었다. 유동 세균이 존재하므로써 오염물이 가속이송되었고, 오염물을 섭취하므로써 그 농도를 낮출 수 있었다.

  • PDF

한강 하류부에서의 오염물질의 거동특성 연구 (A Study on the Contaminant Transport Characteristics in Han River)

  • 김형일;이종설
    • 한국수자원학회논문집
    • /
    • 제31권1호
    • /
    • pp.85-93
    • /
    • 1998
  • 본 연구는 도시하천인 한강 하류부에 2차원 유한요소모형을 적용하여 하천의 수리학적 특성에 따른 오염물질의 거동특성을 모의하고 예측하기 위한 것으로서 흐름상태를 분석할 수 있는 RMA-2V 모형과 동적 수질예측이 가능한 RMA-4모형을 이용하였다. 2차원 유한요소모형을 사용하여 수질의 거동특성을 모의하여 본 결과 유량 및 유속의 변화는 오염물질의 이송확산에 큰 영향을 미치는 것으로 나타났으며, 탄천 및 중랑천은 대상구역내의 수질오염에 큰 영향을 미치는 것으로 나타났다. 불시의 오염사고가 발생했을 때 오염물질이 하류부로 이동함에 따라 최대 COD 값은 감소하고,오염물질이 영향을 미치는 지속기간은 커지는 것을 알 수 있었고, 전체적으로 좌·우안의 오염물질의 농도차가 크게 나타났으며, 이로써 한강과 같은 대하천의 경우 실시간 예측시 2차원 해석이 필요한 것으로 나타났다.

  • PDF

점도변화에 따른 바닥 오염물질의 미끄러짐 저항 특성 (Slip Resistance of Contaminants on the Floor for Variation of Viscosity)

  • 박재석;오환섭
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.185-189
    • /
    • 2012
  • While there is no standards on slip risk for contaminants on surface, glycerol is described in standard contaminant for measuring coefficient of friction(COF) and slip resistance such as ISO 13287. But that is just used to measure the slip resistance of surface materials and shoes not to evaluate the contaminant materials. Therefore the objective of this study was to find out the relationship between standard contaminant and the contaminants used usually at the workplaces. For this, some measurement criteria were acquired from the analysis based on biomechanics and kinetics of human gait during slips. The slip resistance according to viscosity of the contaminants was measured applying the criteria and slip probability was determined by the gait analysis. Some factors which should be considered when measuring the slip resistance were identified. The velocity, acceleration, contact time and contact pressure should be 1 m/sec, 10 $m/sec^2$, 350 kPa and less than 0.5sec respectively. The variation of viscosity according to temperature for working oils was different from that of standard contaminant. The static coefficient of friction (SCOF) of working oils was almost 0.5 times as large as the SCOF of standard contaminant. So it was assumed to be difficult to compare the contaminants at the workplaces with the glycerol as a standard contaminant for estimating the slip risk.

다구획 작업환경에서의 오염농도 예측을 위한 이론적 모델의 개발 (Development of a Theoretical Model for Predicting Contaminant Concentrations in a Multi-zone Work Environment)

  • 조석호
    • 한국산업보건학회지
    • /
    • 제21권4호
    • /
    • pp.185-192
    • /
    • 2011
  • To predict contaminant concentrations within a multi-zone work environment, an air quality model in the work environment was developed. To do this, airflow equations on the basis of orifice equation were solved by using the Conte and De Boor scheme, and then equations for the conservation of mass on contaminant were solved by using the fourth-order Runge-Kutta algorithm. To validate the accuracy of simulated results, this model was applied to the controlled environment chamber that had been tested in 1998 by Chung KC. The comparison of predicted concentrations by this study with measured concentrations by the Chung KC indicated that the average deviations were 2.66, 3.35, and 3.15% for zone 1, zone 2, and zone 3, respectively. Also, this model was applied to a working plant with four zones. Thus, the results of contaminant concentration versus time were predicted according to the schedule of the openings operation, and case studies were done for four cases of the openings operation to investigate the interaction of airflow and contaminant concentration. The results indicated that opening operation schedules had a significant effect on contaminant removal efficiency. Therefore, this model might be able to apply for the design of ventilation schedules to control contaminants optimally.

시뮬레이션을 통한 실내 오염물질 확산의 예측 방법 (A Prediction of the Indoor Contaminant diffusion using Network Simulation)

  • 강기남;송두삼
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.311-318
    • /
    • 2006
  • CFD simulation is a tool very useful to predict the generation and absorption of the contaminant from the construction materials for the single room condition. However, there is a limit in multi-room simulation for analyzing air movement and contaminant concentration at the condition that the door of each room was closed. A lot of network simulation tool were developed which can used to analyze the mass transfer and contaminant concentration as results in the multi-room condition. However, existing network simulation method was not able to analyze the change of the heating and cooling load with the ventilation as though the change of the indoor air-pollution density was predictable. In this study, new approach to predict heating/cooling load and indoor contaminant concentration will be reviewed. New indoor contaminant concentration module reviewed in this study wad coupled with existing ESP-r network simulation method. The validity of new approach will be analysed for comparison the results of simulation and field measurement results.

  • PDF

사용종료 매립장 오염원의 장기 변화 및 안정성 (Long Term Trend and Stability of Contaminant Sources of Finished Landfill)

  • 장연수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1996년도 사용종료 매립지의 안정화 에 관한 국제 세미나
    • /
    • pp.1-40
    • /
    • 1996
  • In order to determine the proper treatment of the finished landfill, it is important to predict the trend and stability of the major sources of contaminant in the landfill. In this paper the fate of contaminant sources in the landfill is studied from various literatures by grouping the contaminants into waste, leachate, and landfill gas. One example site referred is Nanji landfill which is one of the representative finished landfills in our country and the trend of contaminant sources in this landfill at current stage is discussed.

  • PDF

강변여과에서 콜로이드 물질이 오염물 거동에 미치는 영향 (Effect of Colloids on Contaminant Transport in Riverbank Filtration)

  • 김대환;이상일;유상연
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1398-1402
    • /
    • 2005
  • Riverbank filtration is a natural process using alluvial aquifers to remove contaminants and pathogens in river water for the production of drinking water. In riverbank filtration, the understanding of contaminant transport is an important task for the production of high quality drinking water. This study investigates the transport behavior of hydrophobic organic contaminants when colloids (dissolved organic matter and bacteria) are present in the aquifer. A mathematical model for the transport of contaminants is developed and solved numerically for various situations. Results show that in the riverbank filtration the presence of DOM and bacteria enhances the mobility of contaminant significantly. Sensitivity analysis indicates that the distribution of the total aqueous Phase contaminant is significantly affected by distribution coefficients which account for affinity of solid or colloidal Phase to contaminant.

  • PDF

Image Analysis: A Novel Technique to Determine the Efficiency of Wiping Cloths

  • Lee Jae-Hyung;Kim Seong-Hun;Oh Kyung-Wha
    • Fibers and Polymers
    • /
    • 제7권1호
    • /
    • pp.73-78
    • /
    • 2006
  • The ability to absorb liquid and the dust removal performance are important factors for wiping cloths used to remove contaminants. We have developed a method that can determine the contaminant removal performance of wiping cloths. In the gravimetric method, experimental errors are unavoidable because the contaminant plate is much heavier than the contaminant material. However, we used image analysis to reduce the experimental errors, and did not use the heavy contaminant plate. The correlation coefficient between the image. analysis and the gravimetric methods was very high, at R=0.97, with a significance level of 95%. From the correlation analysis and empirical data, the image analysis method is a useful tool for measuring wiping efficiency. The wiping efficiency measured using image analysis has a close relationship to the wiping speed, viscosity of the contaminant, and wiping pressure, at the significance level of 95%.

흡착보양재 적용에 따른 실내 오염물질 초기제어 성능에 관한 연구 (A Study on Initial Control Performance of the Adsorption Protector for Construction Surface about Contaminant)

  • 허정용;최창호;이윤규
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.229-235
    • /
    • 2009
  • In a domestic construction field, floor surface must be covered not to be scratched and polluted by protector until resident comes in. However this protector restricts the contaminant to leave from floor surface. So when the protector is removed, much contaminant is emitted from the floor surface to inside and makes a bad influence on the indoor air quality, In this research, it will be tested the reduction performance of contaminant between a normal protector and a contaminant absorption protector using charcoal powder.