• Title/Summary/Keyword: Containment Area

Search Result 88, Processing Time 0.037 seconds

Evaluation of Contaminant Retardation Capacities of Bank Aquifer Materials (강변 대수층 매질 시료의 오염물질 지연능 평가)

  • Kim, Jae Young;Oh, Dong Ik;Park, Dong Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.62-71
    • /
    • 1999
  • The containment retardation capacities of four different aquifers were evaluated in a preliminary study for development of bank filtration in the Young San river area. $NO_3-N$, $NO_2-N$, $NH_4^+-N$, Fe, Mn, phenol, and chloride were selected as the target contaminants and a nonreactive tracer, respectively. Batch isotherm tests were conducted to measure the partition coefficients of the target contaminants. The mass transport parameters of nonreactive tracer were estimated from column tests. From the results of bath isotherm tests, it was shown that lower stream aquifer materials have greater partition coefficients of $NO_3-N$, $NH_4^+-N$, Mn, and phenol than the upper stream aquifer materials; however, there was no significant position-dependent trend for Fe. All aquifer materials tested have the same range of partition coefficients for $NO_2-N$. Column tests showed that the molecular diffusion of Cl- was much less than the mechanical dispersion; and there was no significant difference between the estimated dispersivities of tested aquifer materials. Consequently, it seems that the difference in the containment retardation capacities between four aquifers tested in this study would primarily result not from hydrodynamic dispersion but from partitioning.

  • PDF

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

A Study on the Required Stockpiles of Marine Oil Spill Response Equipments in the Busan Area (부산해역에서의 해양오염방제장비의 필요수량에 관한 연구)

  • 윤종휘;윤혁수;김동선
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.8 no.1
    • /
    • pp.139-148
    • /
    • 2002
  • As the Busan harbor is getting susceptible to oil Pollution. the authors analyze the historical records of oil spill accidents and investigate the shoreline features. In addition. we evaluate the response capabilities and compute the required stockpiles of marine oil spill response with the worst case scenario in this area. As a result, it is shown that the recommendable oil spill response is to contain and mechanically recover all oils at sea surface in winter. while chemical dispersants can be used in summer with mechanical containment and recovery, and it is also found that off-shore booms of 3,000m and off-shore skimmers of 986MT/hour recovery rate should be stockpiled with 10,000∼60,000 liters of concentrate chemical dispersant and small amount of synthetic organic sorbents for possible use.

  • PDF

Environments in the East Asia and the way to Utilize Submarines for ROKN: Focused the issue on both American Strategy against China and Japanese Arms Race (동아시아 정세와 한국해군의 잠수함 운용방안 - 미국의 대중(對中) 전략과 일본의 전력 증강을 중심으로 -)

  • Heo, Song
    • Strategy21
    • /
    • s.42
    • /
    • pp.318-346
    • /
    • 2017
  • Currently, security environmental instability is getting worse than ever in the East Asia including to Republic of Korea(ROK). Unlike several conventional issues such as maritime dispute -sometimes with islands- and competitions for getting natural resources, contemporary security dilemma issues followed by arms races among states deepens the power gap between strong and weak state within the region. It is notable that the arms races is the East Asia are mainly focused on naval power. As navy is the very possible force that influences neighboring states, submarine power is usually valued for its nature of stealth, mobile and aggression. Moreover, the submarine power is believed to be one of the highest valued weapon system since it shows actual effectiveness for influencing the other states while avoiding direct military conflicts compared to surface power. As a result, all states within the region are accelerating for getting such power these days. Japan, Most of all, is one of the leading state that aims to ensure self-survival and enlarge military influences under the US-Japan alliance by decisively supporting its power to the American containment strategy against China. In this regard, such movement surely sill influence on ROK both directly and indirectly as we sue the common field, the sea. Though, it has lots of restrictions for us to confront them with military forces as such confrontations within US-led alliances is not desirable upon considering current China and nK threats. As a result, ROK needs to limit the realm of alliance within the region while maintaining ROK-US alliance for getting national interests with both legal and justice superiority against Japan. This paper, as a result, is focused on suggesting the way to utilize submarines as a mean of naval power for both current security environments and the rising maritime threats in the East Asia. I concluded to participate ROK submarines in US-led military strategy against China by dispatching them into the East-China Sea and the North-East area of the Korean peninsula to protect both national interests and justice at the same tome. It should be one of the preemptive measure for confronting with neighboring states by utilizing strategic benefits of submarines while strengthening ROK-US alliances upon participating American Containment Strategy against China.

Chemical Effects on Head Loss across Containment Sump Strainer under Post-LOCA Environment (LOCA이후 환경에서 원자로건물집수조 여과기의 수두손실에 대한 화학적 영향)

  • Ku, Hee-Kwon;Jung, Bum-Young;Hong, Kwang;Jeong, Eun-Sun;Jung, Hyun-Jun;Park, Byung-Gi;Rhee, In-Hyoung;Park, Jong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3260-3268
    • /
    • 2009
  • A test apparatus has been fabricated to simulate chemical effect on head loss through a strainer in a pressurized water reactor (PWR) containment water pool after a loss of coolant accident (LOCA). Tests were conducted under condition of same ratio of strainer surface area to water volume between the test appratus and the containment sump. A series of tests have been performed to investigate the effects of spray, existence of calcium-silicate with tri-sodium phosphate (TSP), and composition of materials. The results showed that head loss across the chemical bed with even a small amount of calcium-silicate insulation instantaneously increased as soon as TSP was added to the test solution. Also, the head loss across the test screen is strongly affected by spray duration and is increased rapidly at the early stage, because of high dissolution and precipitation of aluminum and zinc. After passivation of aluminum and zinc by corrosion, the head loss increase is much slowed down and is mainly induced by materials such as calcium, silicon, and magnesium leached from NUKONTM and concrete. Furthermore, it is newly found that the spay buffer agent, tri-sodium phosphate, to form protective coating on the aluminum surface and reduce aluminum leaching is not effective for a large amount of aluminum and a long spray.

An experimental study on heat transfer of finned vertical cooling tube (휜이 부착된 수직(垂直) 냉각관(冷却管)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的)인 연구(硏究))

  • Song, H.J.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.43-49
    • /
    • 1984
  • Experiments were performed to study freezing on a finned vertical tube when either conduction in the solid or natural convection in a liquid controls the heat transfer. Conduction is the controlling mode when the liquid is at its fusion temperature, whereas natural convection controls when the liquid temperature is above the fusion value. The liquid was housed in a cylinderical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the freezing occurred on a finned vertical tube positioned along the axis of the vessel. The phase change medium was n-octacosan, a paraffin which freezes at about $61^{\circ}C$. For conduction-controlled freezing, the enhancement of the frozen mass due to finning is greatest when the frozen layer is thin and decrease as the layer grows thicker. The degree of enhancement is generally less than the surface area ratio of the finned and unfinned tube.

  • PDF

Development of a tele-robotic system for steam generator maintenance works (원전 증기발생기 유지보수용 원격로봇 시스템 개발)

  • 황석용;김창회;김승호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1519-1522
    • /
    • 1996
  • In this paper, we have developed a tele-robotic system for nozzle dam installation/removal works and tube relating maintenance works inside unclear power plant steam generator. Developed tele-robotic system consists of many hardwares including robot and a control system. Based on the 3 dimensional graphic simulation, a 6 D.O.F. hydraulic actuated robot and a 2 D.O.F. robot install/removal device have been developed. And also we deviced special tools for nozzle dam carry and bolting. For the tele-robot and other devices to be controlled at the nonradioactive area outside reactor containment building, we developed a tele-robot control system consisting of supervisory controller and remote controller.

  • PDF

Post-Fukushima challenges for the mitigation of severe accident consequences

  • Song, JinHo;An, SangMo;Kim, Taewoon;Ha, KwangSoon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2511-2521
    • /
    • 2020
  • The Fukushima accident is characterized by the fact that three reactors at the same site experienced reactor vessel failure and the accident resulted in significant radiological release to the environment, which was about 1/10 of the Chernobyl releases. The safe removal of fuel debris in the reactor vessel and Primary Containment Vessel (PCV) and treatment of huge amount of contaminated water are the major issues for the decommissioning in coming decades. Discussions on the new researches efforts being carried out in the area of investigation of the end state of fuel debris and Boling Water reactor (BWR) specific core melt progression, development of technologies for the mitigation of radiological releases to comply with the strengthened safety requirement set after the Fukushima accident are discussed.

The Verification of TEXAS-V code for TROI Experimental Results and the Evaluation of the Ex-vessel Steam Explosion Load (TROI 실험결과를 활용한 TEXAS-V 코드 검증 및 원자로 노외증기폭발 하중평가)

  • Park, Ik-Kyu;Kim, Jong-Hwan;Min, Beong-Tae;Hong, Seong-Ho;Kim, Hee-Dong;Hong, Seong-Wan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3485-3490
    • /
    • 2007
  • The TEXAS-V code tuned for TROI-13 was used for analyzing the parametric findings in TROI experiments. The calculations on the melt composition are relatively similar to the TROI experimental results. The water depth effect in TEXAS-V code seems to be consistent with TROI experiments in some degree. The water area effect of TEXAS-V calculations seems not to be harmonious to that in TROI experiments. This seems to indicate that TEXAS-V as 1-dimensional code or as the numerical steam explosion has a limitation on estimating area effect. Thus, TEXAS-V tuned for TROI-13 seems to have an ability to estimate the parametric effect of TROI experiments. The evaluated TEXAS-V was used for estimating the ex-vessel steam explosion load. The calculated explosion pressure and load were about 40 MPa and 75 kPa.sec, which are not much threatening level for containment integrity, but are arguable value for the integrity.

  • PDF

Effect of Reinforcement Ratio and Impact Velocity on Local Damage of RC Slabs (철근비 및 충돌속도가 RC 슬래브의 국부손상에 미치는 효과)

  • Choi, Hyun;Chung, Chul Hun;Yoo, Hyeon Kyeong;Kim, Sang Yun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4A
    • /
    • pp.311-321
    • /
    • 2011
  • To analysis the effect of reinforcement ratio and impact velocity on local damage, a series of impact analyses are performed to predict local effects. According to these results, the reinforcement ratio has no effect on the penetration depth and perforation thickness, but notable change to the scabbing area were observed. The higher the missile velocity becomes, the greater the degree of local damage to the reinforced concrete slabs is. Analysis results will be useful in the impact-resistance design of containment buildings and structures.