• Title/Summary/Keyword: Contact-error

Search Result 410, Processing Time 0.024 seconds

Touch-Pen Noise Reduction Using B-Spline Function (B-Spline 곡선을 이용한 터치펜 잡음제거)

  • Lee, Sang-Bum
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.121-126
    • /
    • 2017
  • Recently, a lot of people use touch-pen devices such as smart phones and tab computers. To generate the picture and text, a user can give input or control the touch-pen device through simple or multi-touch gestures by touching the screen with a special stylus pen and/or one or more fingers. The accuracy and response time from the moment of contact with the touch board is very important to the touch device. Therefore, research is needed to find a way of removing the noise included in the touch signal quickly and efficiently. In this paper, we propose a method for removing a noise mixed in with a touch point coordinate which has been caused by a input pen on the touch screen. For effective filtering, the fast sampling of the coordinate corresponding to the noise from the input signal is required primarily. Secondly the total compensation of the touch coordinates using the characteristics of the B-Spline curve is applied to correct coordinates of the points. This method can ensure a real-time response than other algorithms. The applied performance evaluation method is comparing error pixels with evaluation values by dividing 10 intervals on the touch pad diagonally. Usually the average error is 7.1 pixels but our proposed method shows an average 4.1 errors. Therefore, our proposed touch pen method can express the input signal on the coordinates more correctly.

A Study on the Side Impact Characteristics Occurred from SUV-to-Passenger Car using LS-DYNA (LS-DYNA를 이용한 SUV와 승용차의 측면충돌 특성에 대한 연구)

  • Lim, Jong-Han
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.2
    • /
    • pp.217-226
    • /
    • 2018
  • Since the sides of a vehicle are designed asymmetrically unlike its front or rear, the degree of deformation of the car body greatly differs depending on the site of collision if a broadside collision takes place. When elastic deformation and plastic deformation occur in the car body occur due to a collision, the kinetic energy is absorbed into the body, and the momentum decreases. Generally, an analysis of traffic accidents analyzes the vehicle's behavior after a collision by the law of momentum conservation and corrects the error of the amount of energy absorption due to the deformation of the car body, applying a restitution coefficient. This study interpreted a finite element vehicle model applying the structure of the car body and the material properties of each part with LS-DYNA, analyzed the result and drew the restitution coefficient and the depth of penetration according to the contact area of the vehicle in a broadside collision between an SUV and a passenger car. When the finally calculated restitution coefficient and depth of penetration were applied to the examples of the actual traffic accidents, there was an effect on the improvement of the error in the result. It was found that when the initial input value, drawn using the finite element analysis model, it had a higher reliability of the interpretation than that of the existing analysis techniques.

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.

Evaluation on machining accuracy according to convergence angle and radius of curvature value used for fabricating custom abutments (맞춤형 지대주 제작에 사용되는 수렴 각과 곡률 반경의 값에 따른 가공 정확도 평가)

  • Hong, Min-Ho;Choi, Sung-Min;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.329-336
    • /
    • 2017
  • This study evaluates the machining accuracy of the custom abutment design according to the selected convergence angle and radius of curvature value in the CAD program. Ten custom abutments were designed based on dental CAD. And then, the fabricated custom abutment was scanned ten times using a contact scanner. The data of the scanned custom abutment was saved as "Test STL" file. The Geomagic studio software was used to superposition each exported as an "Test STL" file with the CAD-reference-model STL file (CRM) specified by the same name. In the experimental results, the A8 group (convergence angle $8^{\circ}$) showed lower error than the A4 group (convergence angle $4^{\circ}$) . In addition, the higher the radius of curvature, the less error in the top and chamfer regions of the custom abutment (p< 0.05). Overall, the convergence angle and radius of curvature value in the custom abutment design were found to affect the machining accuracy.

Accuracy Analysis of Indoor Positioning System Using Wireless Lan Network (무선 랜 네트워크를 이용한 실내측위 시스템의 정확도 분석)

  • Park Jun-Ku;Cho Woo-Sug;Kim Byung-Guk;Lee Jin-Young
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.65-71
    • /
    • 2006
  • There has been equipped wireless network infrastructure making possible to contact mobile computing at buildings, university, airport etc. Due to increase of mobile user dramatically, it raises interest about application and importance of LBS. The purpose of this study is to develop an indoor positioning system which is position of mobile users using Wireless LAN signal strength. We present Euclidean distance model and Bayesian inference model for analyzing position determination. The experimental results showed that the positioning of Bayesian inference model is more accurate than that of Euclidean distance model. In case of static target, the positioning accuracy of Bayesian inference model is within 2 m and increases when the number of cumulative tracking points increase. We suppose, however, Bayesian inference model using 5- cumulative tracking points is the most optimized thing, to decrease operation rate of mobile instruments and distance error of tracking points by movement of mobile user.

Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP (다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석)

  • Ji, Ju-Yeon;Park, Seung-Yong;Lee, Gwang-Woo;Park, Gyeong-Min;Hwang, Soon-Hong;Kim, Dong-Ho;Lee, Young-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

A Study on Optimization of Tooth Micro-geometry for Wind Turbine High Speed Stage Helical Gear Pair (풍력터빈용 고속단 헬리컬 기어의 치형 최적화에 관한 연구)

  • Cho, Sungmin;Lee, Do-Young;Kim, Laesung;Cho, Sangpil;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.15-20
    • /
    • 2014
  • The wind industry grew in the first decade of the 21st century at rates consistently above 20% a year. For wind turbine, gearbox failure can be extremely costly in terms of repair costs, replacement parts, and in lost power production due to downtime. In this paper, gear tooth micro-modification for the high speed stage was used to compensate for the deformation of the teeth due to load and to ensure a proper meshing to achieve an optimized tooth contact pattern. The gearbox was firstly modeled in a software, and then the various combined tooth modification were presented, and the prediction of transmission under the loaded torque for the helical gear pair was investigated, the normal load distribution and root stress were also obtained and compared before and after tooth modification under one torque. The simulation results showed that the transmission error and normal load distribution under the load can be minimized by the appropriate tooth modification. It is a good approach where the simulated result is used to improve the design before the prototype is available for the test.

Minimizing the extra-oral time in autogeneous tooth transplantation: use of computer-aided rapid prototyping (CARP) as a duplicate model tooth

  • Lee, Seung-Jong;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The maintenance of the healthy periodontal ligament cells of the root surface of donor tooth and intimate surface contact between the donor tooth and the recipient bone are the key factors for successful tooth transplantation. In order to achieve these purposes, a duplicated donor tooth model can be utilized to reduce the extra-oral time using the computer-aided rapid prototyping (CARP) technique. Materials and Methods: Briefly, a three-dimensional digital imaging and communication in medicine (DICOM) image with the real dimensions of the donor tooth was obtained from a computed tomography (CT), and a life-sized resin tooth model was fabricated. Dimensional errors between real tooth, 3D CT image model and CARP model were calculated. And extra-oral time was recorded during the autotransplantation of the teeth. Results: The average extra-oral time was 7 min 25 sec with the range of immediate to 25 min in cases which extra-oral root canal treatments were not performed while it was 9 min 15 sec when extra-oral root canal treatments were performed. The average radiographic distance between the root surface and the alveolar bone was 1.17 mm and 1.35 mm at mesial cervix and apex; they were 0.98 mm and 1.26 mm at the distal cervix and apex. When the dimensional errors between real tooth, 3D CT image model and CARP model were measured in cadavers, the average of absolute error was 0.291 mm between real teeth and CARP model. Conclusions: These data indicate that CARP may be of value in minimizing the extra-oral time and the gap between the donor tooth and the recipient alveolar bone in tooth transplantation.

Quantitative Analysis of 3-D Displacements Measurement by Using Holospeckle Interferometry (홀로스펙클 간섭법을 이용한 3차원 변위측정의 정량적 연구)

  • 주진원;권영하;박승옥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1208-1217
    • /
    • 1993
  • The simple and effective optical technique synthesizing holographic interferometry and speckle photography is presented. The optical system used in this experiment is based on image holography. A cantilever beam located on the precision translator is used to evaluate this measurement system. Experimental results agree well with the actual displacements within the error of 2.8%. As an its application, three dimensional contact deformation in the ball indentation is measured by using this optical system and compared with the numerical analysis by finite element method.

A Study on Girls' High School Students for Knowledge and Practice of Eyesight Care (서울시내 일부여고생들의 안경착용률 및 시력보호에 대한 지식과 태도에 관한 연구)

  • 김윤희;곽정옥
    • Korean Journal of Health Education and Promotion
    • /
    • v.10 no.1
    • /
    • pp.87-97
    • /
    • 1993
  • The purpose of this study is to give practical information about eyesight care-preventing refractive error and actual conditions of wearing glasses(or contact lenses) to help school health education, For this study, 1,216 freshmen were sampled from liberal and vocational high schools in Seoul and the survey was successfully accomplished. Following are the major findings results of this study: 1. The percentage of the freshmen wearing glasses in girls high school were 57.5 percent in liberal high school and 41.7 percent in vocational high school. 2. The percentage of both the students and parents wearing glasses were 49.9 percent in liberal high school and 33.8 percent in vocational high school. 3. From the survey, the majority of the students began to wear glasses during their middle school years. The percentages were 46.6 percent in liberal high school and 62.1 percent in vocational high school. 4. The percentage of the students who got their glasses prescribed from an ophthalmic clinic were 60.6 percent in liberal high school, 31.5 percent in vocational high school and the rest got their glasses from the optician.. 5. The percentage of the students wearing glasses who didn't have optometry check-up for 6 months were 57.2 percent in liberal high school and 38.4 percent in vocational high school. The percentage of the students not wearing glasses in the same situation were 61.9 percent in liberal high school and 41.5 percent in vocational high school. 6. The percentage of the students who believe that the health education in school is necessary for the prevention of amblyopia were 79.2 percent of strdents attending in liberal high school, 82.9 percent in vocational high school, 81.5 percent of students wearing glasses and 80.8 percent of students not wearing glasses.

  • PDF