• Title/Summary/Keyword: Contact surface area ratio

Search Result 68, Processing Time 0.027 seconds

A Comparison of the Contact Area between Three Different Correcting Angles after Proximal Crescentic Osteotomy and Ludloff Osteotomy of the First Metatarsal (Preliminary Report) (제1 중족골 근위 반월형 절골술과 Ludloff 절골술 후 교정 각도에 따른 절골편간 접촉 면적 비교(예비보고))

  • Park, Yong-Wook;Jang, Keun-Jong;Park, Sang-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.5-10
    • /
    • 2010
  • Purpose: This study was performed to compare the contact area between three different correcting angles after the proximal crescentic and Ludloff osteotomies of the first metatarsal. Materials and Methods: We used the two sawbone models. Proximal crescentic (PCO) and Ludloff osteotomies (LO) were performed and secured using K-wires under the correcting intermetatarsal angle (IMA) $5^{\circ}$, $10^{\circ}$, and $15^{\circ}$. Then each 6 osteotomized model was scanned five times and measured the contact area using the calculating program. We excluded the highest and lowest values. Results: The mean area of cutting surface was 189 $mm^2$ in PCO, 863 $mm^2$ in LO. The mean contact area (contact ratio; contact area $\times$100/area of cutting surface) of PCO was 149 $mm^2$ (79%) in $5^{\circ}$, 139.5 $mm^2$ (74%) in $10^{\circ}$, 107 $mm^2$ (57%) in $15^{\circ}$ IMA. The mean contact area (contact ratio) of LO was 711 $mm^2$ (82%) in $5^{\circ}$, 535.5 $mm^2$ (62%) in $10^{\circ}$, 330 $mm^2$ (38%) in $15^{\circ}$ IMA. Conclusion: A significant decrease in the contact area and contact ratio according to increase in correcting IMA was noticed in LO. We recommend the PCO rather than LO, when the IMA is needed to correct over $15^{\circ}$.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Development of the non contact tongue moisture measuring device (비접촉식 설면 습윤도 측정 기구의 개발)

  • Kim, Dae-Bok;Park, Yu-Gyung;Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

A Bonding Surface Behavior of Bi-metal Bar through Hydrostatic Extrusion (이중복합봉 정수압 압출시 접합면 거동에 관한 연구)

  • Park, Hun-Jae;Na, Gyeong-Hwan;Jo, Nam-Seon;Lee, Yong-Sin
    • Transactions of Materials Processing
    • /
    • v.7 no.1
    • /
    • pp.66-71
    • /
    • 1998
  • The present study is concerned with the hydrostatic extrusion process of copper-clad aluminium bar to investigate the bonding conditions as well as the basic flow characteristics. Considering the bonding mechanism of bi-metal contact surface as cold pressure welding the normal pressure and the contact surface expansion are selected as process parameters governing the bonding conditions, in this study the critical normal pressure required for the local extrusion-the protrusion of virgin surfaces by the surface expansion at the interface-is obtained using a slip line method and is then used as a criteron for the bonding. A rigid plastic finite element method is used to analyze the steady state extrusion process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-process. The interface profile of bi-metal rod is predicted by tracking the paths of two particles adja-cent to interface surface. The contact surface area ration and the normal pressure along the interface are calculated and compared to the critical normal pressure to check bonding. It is found that the model predictions are generally in good agreement with the experimental observations. The compar-isons of the extrusion pressure and interface profile by the finite element with those by experi-ments are also given.

  • PDF

Electricity generation from surface floating air cathode microbial fuel cell according to the wastewater flow-rate and the ratio of cathode surface area to anode surface area (표면부유 공기양극 미생물연료전지에서 유량 및 전극 면적비에 따른 전력생산 특성)

  • Yoo, Kyu-Seon;Song, Young-Chae;Woo, Jung-Hui;Chung, Jae-Woo;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.591-596
    • /
    • 2011
  • Surface floating air cathode microbial fuel cell (MFC) having horizontal flow was developed for the application of MFC technology. RVC (Reticulated vitreous carbon) coated with anyline was used as anode electrode and carbon cloth coated with Pt (5.0 g Pt/$m^2$, GDE LT250EW, E-TEK) was used as cathode electrode. As results of continuous operation with changing the flow rate from 4.3 mL/min to 9.5 mL/min, maximum power density of 4.5 W/$m^3$ was acquired at 5.4 mL/min, which was at 0.35 m/hr of flow velocity under anode electrode. When the ratio of cathode surface area to anode surface area($A_c/A_a$) was changed to 1.0, 0.5, and 0.25, the maximum power density of 2.7 W/$m^3$ was shown at the ratio of 1.0. As the ratio decreased from 1.0 to 0.25, the power density also decreased, which is caused by increasing the internal resistance resulted from reducing the surface area to contact with oxygen. Actually, internal resistances of the ratio of 1.0, 0.5, and 0.25 were 63.75${\Omega}$, 142.18${\Omega}$, and 206.12${\Omega}$, respectively.

A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS (자연치열자와 가철성 국소의치 장착자의 저작효율과 근활성도에 관한 비교 연구)

  • Paik, Jin;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.81-103
    • /
    • 1998
  • The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial denture wearers. Twenty healthy adult subjects with more than 28 teeth and thirteen removable partial denture wearers that classified Kennedy classification I was selected. The degree of pulverized rice and peanut was measured and analyzed by means of sieving method to compare the masticatory performance. For the muscle activity, EMG was recorded in selected muscles(Temporalis and masseter muscle) during mastication and resting state. The occlusal record in maximal intercuspation was taken with a silicone occlusal bite registration material for analysis of the patterns of occlusal contact. The obtained results were as follows: 1. When chewed peanuts, masticatory performance ratio at 10-sieve size was 81.31% in natural dentition group. In removable partial denture wearer, 27.01% without RPD and 69.09% with RPD. When chewed rice, 42.04%, 11.87%, and 21.58%, respectively. The differences of masticatory performance ratio between groups were statistically significant at the 0.05 level. 2. The mean EMG value in resting state was $1.06{\mu}V$ on temporal muscle, $0.98{\mu}V$ on masseter muscle in natural dentition group. In removable partial denture wearers, $1.13{\mu}V$ on temporal muscle, $1.05{\mu}V$ on masseter muscle without RPD and $1.11{\mu}V$ on temporal muscle, $1.04{\mu}V$ on masseter muscle with RPD. 3. The mean EMG value during mastication was $45.64{\mu}V$ in natural dentition group, and in removable partial denture wearers, $22.06{\mu}V$ without RPD and $31.01{\mu}V$ with RPD when chewed peanuts. When chewed rice, $45.24{\mu}V,\;25.53{\mu}V\;and\;32.14{\mu}V$, respectively. The differences of mean masticatory EMG value between groups were statistically significant at the 0.05 level. 4. The number of posterior occlusal contact point was 20.15 in natural dentition group and 11.92 in removable partial denture wearers. The area of perforated surface was $16.50mm^2$ in natural dentition group and $6.06mm^2$ in removable partial denture wearers. The area of contact surface was $78.93mm^2,\;51.52mm^2$, respectively. 5. The area of contact surface was effective to masticatory performance ratio in natural dentition group and removable partial denture wearers (p<0.05). From these results, it is concluded that in partially edentulous patient, masticatory efficiency can be improved by removable partial denture wearing, and for efficient mastication, tight occlusal contact surface shoud be maintained by maximum support that is provided from mucosa.

  • PDF

Contact analysis of spherical ball and a deformable flat model with the effect of tangent modulus

  • Sathish Gandhi, V.C.;Ramesh, S.;Kumaravelan, R.;Thanmanaselvi, M.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.1
    • /
    • pp.61-72
    • /
    • 2012
  • The paper is on contact analysis of a spherical ball with a deformable flat, considering the effect of tangent modulus on the contact parameters of a non-adhesive frictionless elastic-plastic contact. The contact analysis of this model has been carried out using analysis software Ansys and Abaqus. The contact parameters such as area of contact between two consecutive steps, volume of bulged material are evaluated from the formulated equations. The effect of the tangent modulus is considered for determining these parameters. The tangent modulus are accounted between 0.1E and 0.5E of materials E/Y value greater than 500 and less than 1750. Result shows that upto an optimal tangent modulus values the elastic core push up to the free surface in the flat. The simulation is also carried out in Abaqus and result provide evidence for the volume of bulged material in the contact region move up and flow into the free surface of the flat from the contact edge between the ball and flat. The strain energy of the whole model is varied between 20 to 40 percentage of the stipulated time for analysis.

ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS (임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구)

  • Kim, Yong-Jae;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

Shape Optimization of an Automotive Wheel Bearing Seal Using the Response Surface Method (반응표면법을 사용한 자동차용 휠 베어링 시일의 형상 최적화)

  • Moon, Hyung-Ll;Lm, Jong-Soon;Kim, Heon-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.84-90
    • /
    • 2010
  • This paper presents the shape optimization process for the automotive wheel bearing seal lip using the finite element method and the response surface method. First, to predict performance of the bearing seal lip, we used the non-linear finite element analysis. And then, we compared the analysis results with the test results to verify the finite element model. The objective function in optimizing process was obtained from results of the mud slurry test, which is one of many tests for evaluating performance of wheel bearing. After the mud slurry test for the four models which have the similar cross-sectional shape, we measured the wear area of the seal lip and the moisture content in grease. The objective function has been chosen by comparing the results of mud slurry test and characteristics of seal lip, such as contact force, contact area, contact pressure, and interference. Finally, within limited design parameters, we suggested the optimized shape of seal lip, which is expected to improve the wear and the sealing effect of it.

Fabrication of High-Aspect-Ratio Microscale Polymer Hairs Having Surface Wrinkles (고 세장비 표면주름을 가진 마이크로 폴리머 헤어 제작)

  • Park, Sang-Hu;Kim, Seong-Jin;Park, Hee-Jin;Lee, Joo-Chul;Shin, Bo-Sung
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.1-4
    • /
    • 2013
  • We proposed a new process to fabricate a high-aspect-ratio microhair having surface wrinkles using the contact-and-tension of a microstamp. Through this work, we observed that regular surface wrinkles were generated on the hair with a diameter of around $20{\mu}m$ due to the uni-directional compressive stress during the photocuring process by ultraviolet light. To do this, we conducted an experimental system setup for contact-and-tension process. From the preliminary test results, we believed that the proposed method can be applied to make a long polymer hair having surface wrinkles for special applications to biomimetics, and some research fields related on surface area such as heat transfer and catalyst enhancement.