• Title/Summary/Keyword: Contact size effect

Search Result 261, Processing Time 0.03 seconds

Dynamic Interaction of Track and Train System on Open Gap by Rail Breaks (레일 파단시 장대레일 개구부에서의 궤도-차량 동적상호작용)

  • Kang, Yun Suk;Kang, Young Jong;Yang, Shin Chu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.895-904
    • /
    • 2008
  • CWR (Continuous Welded Rail) may be broken when a temperature drop below the neutral temperature changes in axial force, causing tensile fracture and rail gap, in winter. Rail-breaks may lead to the damage of the rail and wheel by dynamic load, and the reduction of running safety if not detected before the passage of a train. In this study, the track and train coupled model with open gap for dynamic interaction analysis, is proposed. Linear track and train systems is coupled by the nonlinear Herzian contact spring and the complete system matrices of total track-train system is constructed. And the interaction phenomenon considering open gap, was defined by assigning the irregularity functions between the two sides of a gap. Time history analysis, which have an iteration scheme such as $Newmark-{\beta}$ method based on Modified Newton-Raphson methods, was performed to solve the nonlinear equation. Finally, numerical studies are performed to assess the effect of various parameters of system, apply to various speeds, open gap size and the support stiffness of rail.

Effect of perlite powder on properties of structural lightweight concrete with perlite aggregate

  • Yan, Gongxing;Al-Mulali, Mohammed Zuhear;Madadi, Amirhossein;Albaijan, Ibrahim;Ali, H. Elhosiny;Algarni, H.;Le, Binh Nguyen;Assilzadeh, Hamid
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.393-411
    • /
    • 2022
  • A high-performance reactive powder concrete (RPC) has been readied alongside river sand, with 1.25 mm particle size when under the condition of 80C steam curing. As a heat and sound insulation, expanded perlite aggregate (EPA) provides economic advantages in building. Concrete containing EPA is examined in terms of cement types (CEM II 32.5R and CEM I 42.5R), doses (0, 2%, 4% and 6%) as well as replacement rates in this research study. The compressive and density of concrete were used in the testing. At the end of the 28-day period, destructive and nondestructive tests were performed on cube specimens of 150 mm150 mm150 mm. The concrete density is not decreased with the addition of more perlite (from 45 to 60 percent), since the enlarged perlite has a very low barrier to crushing. To get a homogenous and fluid concrete mix, longer mixing times for all the mix components are necessary due to the higher amount of perlite. As a result, it is not suggested to use greater volumes of this aggregate in RPC. In the presence of de-icing salt, the lightweight RPC exhibits excellent freeze-thaw resistance (mass is less than 0.2 kg/m2). The addition of perlite strengthens the aggregate-matrix contact, but there is no apparent ITZ. An increased compressive strength was seen in concretes containing expanded perlite powder and steel fibers with good performance.

Metamorphism of the amphibolites in the Hwanggangri area, the northeastern region of Ogcheon metamorphic belt, Korea (옥천변성대 북동부 황강리 지역내 앰피볼라이트의 변성작용)

  • 유영복;김형식;권용완;박종길
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.57-81
    • /
    • 2001
  • In the amphibolites of the Hwanggangri area, three metamorphic zones are established like hornblende-actinolite zone (H-AZ), hornblende zone (HZ) and diopside zone (DZ) by the main mineral assemblages. Hornblende zone and hornblende-actinolite zone develope away from the diopside zone that experienced the highest thermal effect. Thus, this pattern identifies the decreasing metamorphic grade of the contact metamorphism with increasing distance from the granitic pluton. The mineral assemblages of this rock are classified into six representative groups such as $\circled1$ actinolite+plagioclase+chlorite, $\circled2$ actinolite+hornblende+plagioclase+chlorite$\pm$epidote$\pm$biotite, $\circled3$ actinolite+hornblende+plagioclass$\pm$biotite$\pm$epidote, $\circled4$ hornblende+plagioclase$\pm$biotite$\pm$chlorite, $\circled5$ hornblende+plagioclase+diopside+actinolite$\pm$epidote$\pm$chlorite, $\circled6$hornblende+plagioclase+diopside$\pm$biotite$\pm$epidote. Two metamorphic events m recognized in the amphibolites of the study area that the first metamorphism is the regional metamorphism dominantly occurred in the whole Ogcheon metamorphic belt and it gave rise to the growth of actinolite at the core or center of the amphibole grains of coarse and medium size. Its metamorphic grade ranges from the greenschist facies to epidote-amphibolite facies. The second metamorphism overlapped is the contact metamorphism caused by the adjacent granitic pluton, and its metamorphic grade is thought to reach to the low pressure part of upper amphibolite facies. According to the calculation by TWEEQU thermobarometry and amphibole-plagioclase thermometry, the metamorphic temperature of initial regional metamorphism is $439-537^{\circ}C$ under pressure of 4.6-7.3 kb and its peak temperature and pressure are considered to reach to the range of 492-537 and 5.2-7.3 kb. And the temperature range of contact metamorphism occurred by intrusion of cretaceous granitic body, is $588-739^{\circ}C$ under pressure of 2.6-5.2 kb and its peak temperature and pressure are estimated as having the range of $697-739^{\circ}C$ and 3.8-5.2 kb that this amphibolites are estimated to pass through the metamorphic evolution of both the rise of temperature and the drop of pressure.

  • PDF

Field Case Study for the Productivity Analysis of B2 Reservoir, Donghae-1 Gas Field (동해-1 가스전 B2 저류층의 생산성 분석에 관한 Field Case Study)

  • Kwon Sun-Il;Ryou Sangsoo;Kwon Oukwang;Sung Wonmo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.60-72
    • /
    • 2001
  • This paper presents the user-interactive productivity analysis model based on material balance as well as deliverability equations equipped with EOS model to perform a productivity analysis for Gorae V structure, Donghae-1 gas field. This model is designed to be able to analyse the productivity in the case of reservoir contacting with the aquifer. Also, in order to investigate the effect of condensation on productions, condensation phenomenon is considered as an apparent skin effect in the computation of bottomhole pressure from average reservoir pressure. By utilizing the developed model, we investigate the productivity analysis for B2 layer of Garae V structure with the various production cases in volumetric and non­volumetric reservoirs that contact with aquifer. From the results in the case of 5500 MMSCF/year of production and reservoir-aquifer contacting angle 270$^{\circ}C$ with aquifer size of 10 times greater than reservoir, B2 layer could maintain peak production rate even after 8.5 years of production by considering the bottomhole pressure which is estimated above the operating pressure of 1298 psia. It is also found that condensate will be formed after 1100 days of production and existed throughout the reservoir at 1270 days. Note that the computed reservoir pressure of B2 layer is maintained sufficiently high enough for production due to the water influx into the reservoir, and skin effect caused by condensation is not significant.

  • PDF

Evaluation of Effect of Silvernanoparticle Treated Implant on Bone Formation (은나노 처리된 임플란트의 골조직 형성에 미치는 효과 평가)

  • Kim, Sin-Guen;Yoon, Youn-Jin;Lee, Young-Man;Lee, Tae-Sun;Choi, Dong-Won;Song, Yun-Jung;Park, Jun-Woo;Choi, Dong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.233-238
    • /
    • 2012
  • Purpose: To evaluate the effect of silvernanopartilce treated implants on the bone formation and osseointegration. Methods: Silvernanoparticle was produced using an anodic oxidation method. The size of silvernanoparticle ranged from 3.5 nm to 5.9 nm. To check the effect of the capability of osseointegration of silvernanoparticle coated Implant, 32 implants (16 piece of Implant treated with nanoparticle, and 16 piece of Implant was not treated for control) were placed at both the tibia of 8 New Zealand white rabbits. After 4 weeks, 4 rabbits were sacrificed and the removal torque was measured for comparison of the osseointagration ability. Further, 4 rabbits were sacrificed and sliced samples were made. H&E stain was done for microscopic finding. Results: The removal torque of the experimental group was $102.37{\pm}30.54$ N/cm, and the control group was $73.30{\pm}19.97$ N/cm. It was statistically significant (P<0.001). Microscopic finding also shows extinguish results in silvernanoparticle treated implants. Bone formation rate of the experimental group was 43.94% and the control group was 7.58%. It was observed to be statistically significant (P=0.017). Bone to implant contact rate of the experimental group was 58.09%, and the control group was 19.43%. It was found with statistical significance (P<0.001). Conclusion: The silvernanopartilce treated implant shows a better capability of bone regeneration and osseointegration than the non-treated one. Technology to produce smaller particles would make silver more useful and safer.

The effect of a pulsed-Nd:YAG laser irradiation on microstructure of human gingiva (파동형 Nd:YAG 레이저조사가 인체 치은조직의 미세구조에 미치는 영향)

  • Han, Kyung-Yoon;Shin, Kwang-Yong;Kim, Chun-Seok;Kim, Hyung-Soo;Yum, Chang-Yup;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.317-328
    • /
    • 1997
  • Since laser therapy has been applied to dentistry, many dental practitioners are very interested in laser therapy on various intraoral soft tissue lesions including gingival hyperplasia and aphthous ulcer. The purpose of the present study was to determine the therapeutic effect and the harmful effect of a pulsed-Nd:YAG laser irradiation on human gingival tissue. In twenty periodontal patients with gingival enlargement, the facial gingival surface of maxillary anterior teeth was randomly irradiated at various power of 1.0W(100mJ, 10Hz), 3.0W(100mJ, 30Hz) and 6.0W(l50mJ, 40Hz) for 60 seconds by contact delivery of a pulsed-Nd:YAG laser(EN.EL.EN060, Italy). Immediately after laser irradiation, the gingival tissues were surgically excised and prepared in size of 1mm3. Subsequently the specimens were processed for prefixation and postfixation, embedded with epon mixture, sectioned in $1{\mu}$ thickness, stained with uranyl acetate and lead citrate, and observed under transmission electron microscope(JEM 100 CXII). Following findings were observed; l. In the gingival specimens irradiated with l.OW power, widening of intercelluar space and minute vesicle formation along the widened intercellular space were noted at the epithelial cells adjacent to irradiated area. 2. In the gingival specimens irradiated with 3.0W power, the disruption of cellular membrane, aggregation of cytoplasm, and loss of intercellular space were observed at the epithelial cells adjacent to irradiated area. 3. In the gingival specimens irradiated with 6.0W power, the disruption of nuclear and cellular membrane was observed at the epithelial cells adjacent to irradiated area. The ultrastructural findings of this study suggest that surgical application of a pulsed-Nd:YAG laser on human gingival tissue may lead somewhat delayed wound healing due to damage of epithelial cells adjacent to irradiated area.

  • PDF

Structural and Electrochemical characterization of LiCoO2 Nano Cathode Powder Fabricated by Mechanochemical Process (기계 화학법에 의해 제작된 나노 LiCoO2 양극 분말의 구조 및 전기화학적 특성)

  • Choi, Sun-Hee;Kim, Joo-Sun;Yoon, Young-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.1
    • /
    • pp.86-91
    • /
    • 2004
  • $LiCoO_2$ cathode powders with round particle shaped and nano grain sized of 70-300nm were synthesized by a mechanochemical method. The surface of Li-Co precursor prepared by freeze drying method was modified by $K_2SO_4$ coating and ball milling was used for the coating process. The precursor was crystallized to high temperature form of $LiCoO_2$ at $800^{\circ}C$ and the grain growth was inhibited by the $K_2SO_4$ coating effect. The $K_2SO_4$ coating was not decomposed at $800^{\circ}C$ and prevented the contact in the Li-Co precursor particles. The nano-sized $LiCoO_2$ powder had tetragonal phase and it affected the Li diffusion through the surface of particles. It means that the anode materials for hight performance battery should be satisfied not only small particle size but phase contol on the surface of particles. In this study, the powder characteristics and rate capabilities were compared with a commercial powder and the nano-sized $LiCoO_2$ powder fabricated by the mechanochemical method. And the crucial factor which affects on battery performance was also examined.

What is the effect of initial implant position on the crestal bone level in flap and flapless technique during healing period?

  • Al-Juboori, Mohammed Jasim;Ab Rahman, Shaifulizan;Hassan, Akram;Ismail, Ikmal Hisham Bin;Tawfiq, Omar Farouq
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: The level of the implant above the marginal bone and flap design have an effect on the bone resorption during the healing period. The aim of this study is to detect the relationship between the level of the implant at the implant placement and the bone level at the healing period in the mesial and distal side of implants placed with flapless (FL) and full-thickness flap (FT) methods. Methods: Twenty-two nonsubmerged implants were placed with the FL and FT technique. Periapical radiographs were taken of the patient at implant placement, and at 6 and 12 weeks. By using computer software, bone level measurements were taken from the shoulder of the healing cap to the first bone implant contact in the mesial and distal side of the implant surface. Results: At 6 weeks, the correlation between the crestal bone level at the implant placement and crestal bone level of the FT mesially was significant (Pearson correlation coefficient=0.675, P<0.023). At 12 weeks, in the FT mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.297, P<0.346). At 6 weeks in the FT distally, the correlation was nonsignificant (Pearson correlation coefficient=0.512, P<0.107). At 12 weeks in the FT distally, the correlation was significant (Spearman correlation coefficient=0.730, P<0.011). At 6 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient=0.083, P<0.809). At 12 weeks in the FL mesially, the correlation was nonsignificant (Spearman correlation coefficient= 0.062, P<0.856). At 6 weeks in the FL distally, the correlation was nonsignificant (Spearman correlation coefficient=0.197, P<0.562). At 12 weeks in the FL distally, the correlation was significant (Pearson correlation coefficient=0.692, P<0.018). Conclusions: A larger sample size is recommended to verify the conclusions in this preliminary study. The bone level during the healing period in the FT was more positively correlated with the implant level at implant placement than in the FL.

Characterization of Schottky Diodes and Design of Voltage Multiplier for UHF-band Passive RFID Transponder (UHF 대역 수동형 RFID 태그 쇼트키 다이오드 특성 분석 및 전압체배기 설계)

  • Lee, Jong-Wook;Tran, Nham
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.9-15
    • /
    • 2007
  • In this paper, we present the design of Schottky diodes and voltage multiplier for UHF-band passive RFID applications. The Schottky diodes were fabricated using Titanium (Ti/Al/Ta/Al)-Silicon (n-type) junction in $0.35\;{\mu}m$ CMOS process. The Schottky diode having $4{\times}10{\times}10\;{\mu}m^{2}$ contact area showed a turn-on voltage of about 150 mV for the forward diode current of $20\;{\mu}A$. The breakdown voltage is about -9 V, which provides sufficient peak inverse voltage necessary for the voltage multiplier in the RFID tag chip. The effect of the size of Schottky diode on the turn-on voltage and the input impedance at 900 MHz was investigated using small-signal equivalent model. Also, the effect or qualify factor of the diode on the input voltage to the tag chip is examined, which indicates that high qualify factor Schottky diode is desirable to minimize loss. The fabricated voltage multiplier resulted in a output voltage of more than 1.3 V for the input RF signal of 200mV, which is suitable for long-range RFID applications.

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.