• Title/Summary/Keyword: Contact number

Search Result 1,093, Processing Time 0.026 seconds

Adhesion between Carbon Nanotube Arrays with Different Contact Area Measured Using Microactuator (마이크로 구동기를 이용한 탄소나노튜브 어레이의 접촉 면적에 따른 점착력 측정)

  • Choi, Jungwook;Kim, Jongbaeg
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.1
    • /
    • pp.14-18
    • /
    • 2014
  • Adhesion between carbon nanotube (CNT) arrays is measured and characterized for number of different contact areas. The CNT arrays are directly grown on an electrostatic microactuator, and they make contact with each other during the growth process. The pull-out force is precisely applied by the microactuator while the contact status is identified by measuring electrical resistance between the CNT arrays. We have designed different contact areas of 1000, 6000, and 8500 ${\mu}m^2$ between the CNT arrays, and the corresponding adhesion increases from 0.9 to 3.7 ${\mu}N$ as the contact area increases.

Improvement on Surface and Electrical Properties of Polymer Insulator Coated TiO2 Thin Film by Atomic Layer Deposition (원자층 증착장치에 의한 TiO2 박막 코팅된 폴리머 절연체의 표면 및 전기적 특성의 향상)

  • Kim, Nam-Hoon;Park, Yong Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.440-444
    • /
    • 2016
  • Titanium oxide ($TiO_2$) thin films were synthesized on polymer insulator and Si substrates by atomic layer deposition (ALD) method. The surface and electrical properties of $TiO_2$ films synthesized at various ALD cycle numbers were investigated. The synthesized $TiO_2$ films exhibited higher contact angle and smooth surface. The contact angle of $TiO_2$ films was increased with the increase of ALD-cycle number. Also, the rms surface roughness of films was slightly rough with the increase of ALD-cycle number. The leakage current on $TiO_2$ film surface synthesized at various conditions were uniformed, and the values were decreased with the increase of ALD-cycle number. In the results, the performance of $TiO_2$ films for self-cleaning critically depended on a number of ALD-cycle.

A Scheme for Estimating Number of Tags in FSA-based RFID Systems

  • Lim, In-Taek
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.164-169
    • /
    • 2009
  • An RFID system consists of radio frequency tags attached to objects that need to be identified and one or more electromagnetic readers. Unlike the traditional bar code system, the great benefit of RFID technology is that it allows information to be read without requiring contact between the tag and the reader. For this contact-less feature, RFID technology in the near future will become an attractive alternative to bar code in many application fields. In almost all the 13.56MHz RFID systems, FSA (Framed Slot ALOHA) algorithm is used for identifying multiple tags in the reader's identification range. In FSA algorithm, the tag identification time and system efficiency depend mainly on the number of tags and frame size. In this paper, we propose a tag number estimation scheme and a dynamic frame size allocation scheme based on the estimated number of tags.

Effects of Occlusal Factors and Life Event Changes on Temporomandibular Disorders (측두하악장애에서 교합요인과 생활변화의 영향)

  • You-Me Lee;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.181-192
    • /
    • 1994
  • There have been many different theories on the etiology of temporomandibular disorders(TMDs). The objective of the study was to investigate the effects of occlusal fctors and recent life event changes as prediposing fctor on the development of temporomandibjlar disorders. To evaluate the above predisposing factor, the author used T-scan system(Tekscan Co. U.S.A.) for quantitative occlusal analysis, clinical examination for occlusal state and Social Readjustment Rating Scale(SRRS) for recent life event change units (LCU). 63 patients with TMDs and 57 patients with malocclusion presented at Wonkwang University Dental Hospital participated in this study. The subjects were grouped by Angle's classification and presence of absence of TMDs and parafunctional oral habits. Data gained with regard to contact number, contact force, contact time, occlusal state(number of total teeth and occluding teeth, overjet, overbite) and occlusal interferences (protrusive posterior contact, nonworking side interference, and RCP-ICP slide) and recent life event changes. The data were processed and analysed by SAS statistical package program, The results of this study were as follows : 1. There were no significant differences on both quantitative occlusal contact analysis and occlusal state between TMDs group and Angle's malocclusion group. Also, there were no differences among the Angle's classifications. But amount of overjet in TMDs group were more greater than that of malocclusion group. 2. There was no difference on protrusive posterior contact, and balancing contact between TMDs group and Angle's malocclusion group. Premature contact was more frequent in malocclusion group, but RCP-ICP slide was more frequent in TMDs group. And RCP-ICP slide was more freqent in Angle's class II malocclusion than Angle's I or III malocclusion. 3. Life changes units in TMDs group were higher than those in malocclusion group. And recent life change units in group with parafunctional oral habit were higher than those in group without parafunctional oral habits. Clenching was the most common habit among parafunctional oral habits.

  • PDF

Estimation of Heat Generation in Multi-Contact Connector for Superconducting Magnet Application (초전도자석 시스템 응용을 위한 멀티-컨텍 커넥터의 열 발생 특성 평가)

  • Kim, M.S.;Choi, Y.S.;Kim, D.L.;Lee, Y.A.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2012
  • Current leads are one of the important components for carrying the current to the coil in the superconducting magnet system. Heat leakage through the current lead is the major factor of entire heat load in the cryogenic system because current leads carry the current from room temperature to near 4 K, connecting thermally each other. Therefore, minimization heat load through current lead can reduce the operating temperature of superconducting magnet. The semi-retractable current lead, composed of multi-contact connector and HTS element, is one of good options. Comprehension of Multi-contact connector's structure, contact resistance and heat generation is essential for estimating heat generation in current leads. Multi-contact connector has several louvers inside of socket and the shape, number, size of louvers are different with the size of connector. Therefore contact area, current path and contact resistance are also different. In this study, the contact resistance in multi-contact connector is measured using the electrical power as a function of connector's size and temperature. Also, the unique correlation of electrical contact resistance is derived and heat generation is estimated for superconducting magnet application.

Nonlinear Vibration Analysis of Porous Thin Plate with Wire Impact Damping (와이어 충돌감쇠를 갖는 다공성 박판의 비선형 진동 해석)

  • 김성대;김원진;이부윤;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.341-348
    • /
    • 2001
  • In this study, nonlinear vibration analysis of the cylindrical orthotropic porous thin plate under V-shaped tension distribution with wire impact damping is considered. We make dynamic model of the plate under the tension using commercial FEM code and reduce the number of its degrees of freedom using dynamic condensation. The dynamic model of wire is obtained as lumped mass model from string equation. And then we analyze the nonlinear vibration of the plate including the impact phenomenon between the plate and the wire using the reduced mass and stiffness matrices of the plate and lumped model of the wire. The contact phenomenon between them can be described by impact contact elements composed of contact stiffness coefficients from Hertzian contact theory and contact damping coefficients from restitution coefficient between them. And we discussed the results of nonlinear vibration analysis for variations of their design parameters.

  • PDF

Contact Parameter Computation and Analysis of Air Circuit Breaker with Permanent Magnet Actuator

  • Fang, Shuhua;Lin, Heyun;Ho, S.L.;Wang, Xianbing;Jin, Ping;Huang, Yunkai;Yang, Shiyou
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.595-602
    • /
    • 2013
  • An air circuit breaker (ACB) with novel double-breaker contact and permanent magnet actuator (PMA) is presented. Three-dimensional (3-D) finite element method (FEM) is employed to compute the electro-dynamic repulsion forces, including the Holm force and Lorentz force, which are acting on the static and movable contacts. The electro-dynamic repulsion forces of different contact pieces are computed, illustrating there is an optimal number of contact pieces for the ACB being studied. The electro-dynamic repulsion force of each contact, which varies from the outer position to the inner position, is also computed. Finally, the contacts of the double-breaker are manufactured according to the analyzed results to validate the simulations.

Study on the Stress Singularity of Interface Crack by using Boundary Element Method (경계요소법을 이용한 계면균열의 응력특이성에 관한 고찰)

  • Cho, Chong-Du;Kwahk, Si-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.197-204
    • /
    • 1999
  • The boundary element method was used for studying singularities of an interface crack with contact zones. The iterative procedure is applied to estimate the contact zone size. Because the contact zone size was extremely small in a tension field, a large number of Gaussian points were used for numerical integration of the Kernels. Stress extrapolation method and J-integral were used ofr determining stress intensity factors. When the interface crack was assumed to have opened tips, oscillatory singularities appear near the tips of the interface crack. But the interface crack with contact zone which Comninou suggested had no oscillatory behavior. The contact zone size under shear loading was much larger than that under tensile. The stress intensity factors computed by stress extrapolation method were close to those of Comninou's solution. And the stress intensity factor evaluated by J-integral was similar to that by stress extrapolation method.

  • PDF

Thermal-Fluid Coupled Analysis for Injection Molding Process by Considering Thermal Contact Resistance (사출금형의 열접촉 저항을 고려한 성형과정의 열-유동 연계해석)

  • Sohn, Dong-Hwi;Kim, Kyung-Min;Park, Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1627-1633
    • /
    • 2011
  • Injection molds are generally fabricated by assembling a number of plates in which the core and cavity components are assembled. This assembled structure has a number of contact interfaces where the heat transfer characteristics are affected by thermal contact resistance. In previous studies, numerical approaches were investigated to predict the effect of thermal contact resistance on the temperature distribution of injection molds. In this study, thermal-fluid coupled numerical analyses are performed to take into account the thermal contact effect on the numerical evaluation of the mold filling characteristics. Comparisons with experimental results show that the proposed coupled analysis provides more reliable results than the conventional analyses in predicting the mold filling characteristics by taking into account the effect of thermal contact resistance inside the injection mold assembly.

The change of route of HIV transmission for the past 11 years in Korea and the projection of the HIV/AIDS cases to the year 2000 (지난 11년간 국내 HIV 감염 전파경로 및 발생추계)

  • Lee, Soon-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.2 s.53
    • /
    • pp.331-346
    • /
    • 1996
  • Exploring the epidemiological trend of HIV/AIDS is required for making the national AIDS policy. In this study, the trend of HIV/AIDS incidence, rout of transmission and some characteristics of AIDS for the past 11 years in Korea using the reported cases from the national STD screening scheme were reviewed. Based on the results, the trend of main route of transmission according to the year was established by stage and the HIV/AIDS cases in this year was estimated and that to the year 2000 was projected by 'Epimodel' programme. The results were as follows : 1. Of the total infected persons, 76% were in their twenties and thirties, socioeconomically and sexually active age groups. While the transmission by sexual contact overseas was decreasing, the infection through domestic heterosexual and homosexual contact was increasing. 2. In the middle of the 1980's, the infected persons were mainly prostitutes infected through heterosexual contact with the HIV positive foreigner in this county(stage 1). And in the late of the 1980's the main source of infection was the sexual contact overseas and the domestic heterosexual contact(stage 2). Since the early of the 1990's, the infection through the heterosexual contact with non-regular sexual partner in this country has increased rapidly(stage 3), which was the evidence of the possibility of HIV epidemics. After that, it was expected that the infection through the homosexual contacts, the heterosexual contacts with commercial sex workers outside and the non-regular sexual contact inside of this country would increase continuously. In the result, the occurrence of neonatal infection by vertical transmission was expected(stage4). 3. The number of HIV/AIDS was estimated at 572 to 2,313 and the projected number of HIV/AIDS to the you 2000 was around 5,800 including 627 AIDS patients. For the further study on the estimation and projection of HIV/AIDS, it was suggested that the sampling survey on the HIV infection rate in the high risk groups and the sentinel hospital surveillance system should be conducted.

  • PDF