• Title/Summary/Keyword: Contact condition

Search Result 1,540, Processing Time 0.037 seconds

Supercritical Fluid Extraction of Sesame Oil with High Content of Sesamol (초임계 유체를 이용한 세사몰 고함유 참기름 추출 연구)

  • Ju Young-Woon;Son Min-Ho;Lee Ju-Suk;Lee Moon-Young;Byun Sang Yo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.205-209
    • /
    • 2005
  • Studies for the commercial production of sesame oil using th supercriticl carbon dioxide were made. Characteristics of sesame oil containing one of natural antioxidant 'sesamol', which only exist at sesame seed were also studied during the supercritical fluid extraction. Among the various factors influencing the sesamol contents in the sesame oil, the roasting time and temperature were checked, because sesamol can be converted from sesamol in through pyrolysis. We found that the sesamol content was increased rapidly under the condition of roasting temperature over $200^{\circ}C$ with longer roasting time. The sesamol content was increased as the temperature and pressure increased, which was caused by increase of solubility of sesamol against sesamol oil. And the sesamol content was increased also with lower speed of supercritical fluid, which increased the contact time with the raw material. The sesamol content was also increased using water increase up to $1\%$ as the entrainer. When the extraction performance with the supercritical fluid was compared to the conventional compressed extraction, the sesamol content was increased up to 11.5 times with the entrainer.

AN IN-VITRO WEAR STUDY OF INDIRECT COMPOSITE RESINS AGAINST HUMAN ENAMEL (법랑질에 의한 수종의 간접복합레진의 마모에 관한 연구)

  • Yi, Hyun-Jeong;Jeon, Young-Chan;Jeong, Chang-Mo;Jeong, Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.611-620
    • /
    • 2007
  • Statement of problem: Second-generation indirect composite resins have been improved flexural strength, compressive strength, hydrolytic degradation resistance, wear resistance compared to first-generation indirect composite resins, but there are still some problems as hydrolysis and low wear resistance. Some manufacturers claim that wear resistance of their materials has been improved, but little independent study has been published on wear properties of these materials and the properties specified in the advertising materials are largely derived from in-house or contracted testing. Purpose: This study was to evaluate the wear of indirect composite resins (SR Adore, Sinfony, Tescera ATL) and gold alloy against the human enamel. Material and method: Extracted human incisors and premolars were sectioned to $2{\times}2{\times}2mm$ cube and embedded in the clear resin and formed conical shaped antagonist to fit the jig of pin-on-disk tribometer. Total 20 antagonists were stored in distilled water. Five disk samples, 24mm in diameter and 1.5mm thick, were made for each of three groups of indirect composite resins and gold alloy group, and polished to #2,000 SiC paper on auto-polishing machine. Disk specimens were tested for wear against enamel antagonists. Wear test were conducted in distilled water using a pin-on-disk tribometer under condition (sliding speed 200rpm contact load 24N, sliding distance 160m). The wear of the enamel was determined by weighing the enamel antagonist before and after test, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear mechanisms. Statistical analysis of the enamel wear volume, wear track depth and wear tract width of disk specimens were accomplished with one-way ANOVA and the means were compared for significant differences with Scheffe's test. Results: 1. The enamel wear was most in gold alloy, but there were no statistically significant differences among all the groups (P>.05). 2. In indirect composite resin groups, the group to make the most shallow depth of wear tract was Sinfony, followed by Tescera ATL, SR Adoro (P<.05). Gold alloy was shallower than Sinfony, but there was no statistically significant difference between Sinfony and gold alloy (P>.05). 3. The width of wear tract of SR Adore was larger than the other groups (P<.05), and there were no statistically significant differences among the other groups (P>.05). 4. SEM analysis revealed that Sinfony and gold alloy showed less wear scars after test, Tescera ATL showed more wear scars and SR Adore showed the most. Conclusion: Within the limits of this study, Sinfony and gold alloy showed the least wear rates and showed similar wear patterns.

Interaction of Schwann Cells with Various Protein- or Polypeptide-Coated PLGA Surfaces (다양한 단백질과 폴리펩타이드로 코팅된 PLGA 표면과 슈반세포와의 상호관계)

  • Park Ki-Suk;Kim Su-Mi;Kim Moon-Suk;Lee Il-Woo;Rhee John-M.;Lee Hai-Bang;Khang Gil-Son
    • Polymer(Korea)
    • /
    • v.30 no.5
    • /
    • pp.445-452
    • /
    • 2006
  • In this study, we investigated interaction of Schwann cells (SCs) with various cell-adhesive coated polymer surface. We used cell-adhesives that like a fibronectin (FN), fibrinogen(FG), laminin(LM), vitronectin (VN), poly-D-Iysine (PDL), and poly-L-Iysine (PLL) to coat PLGA film surface and evaluated the surface property of coated or not PLGA films by measurement of water contact angle and ESCA. SCs were cultured on coated or non-coated PLGA film surface, and then examined the cell adhesion and proliferation by cell count and SEM observation. Cell count results revealed initial cell adhesion related to protein adsorption on PLGA surface. In addition, serum content in media related to cell proliferation rate. In this result, we recognized that adhesion and proliferation of SCs were affected by specific cell-adhesives. In these results, we recognized that is important to provide the suitable surface environment according to cell types and culture condition for improvement of cell adhesion and proliferation.

Effects of the Ge Prearmophization Ion Implantation on Titanium Salicide Junctions (게르마늄 Prearmophization 이온주입을 이용한 티타늄 salicide 접합부 특성 개선)

  • Kim, Sam-Dong;Lee, Seong-Dae;Lee, Jin-Gu;Hwang, In-Seok;Park, Dae-Gyu
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.812-818
    • /
    • 2000
  • We studied the effects of Ge preamorphization (PAM) on 0.25$\mu\textrm{m}$ Ti-salicide junctions using comparative study with As PAM. For each PAM schemes, ion implantations are performed at a dose of 2E14 ion/$\textrm{cm}^2$ and at 20keV energy using $^{75}$ /As+and GeF4 ion sources. Ge PAM showed better sheet resistance and within- wafer uniformity than those of As PAM at 0.257m line width of n +/p-well junctions. This attributes to enhanced C54-silicidation reaction and strong (040) preferred orientation of the C54-silicide due to minimized As presence at n+ junctions. At p+ junctions, comparable performance was obtained in Rs reduction at fine lines from both As and Ge PAM schemes. Junction leakage current (JLC) revels are below ~1E-14 A/$\mu\textrm{m}^{2}$ at area patterns for all process conditions, whereas no degradation in JLC is shown under Ge PAM condition even at edge- intensive patterns. Smooth $TiSi_2$ interface is observed by cross- section TEM (X- TEM), which supports minimized silicide agglomeration due to Ge PAM and low level of JLC. Both junction break- down voltage (JBV) and contact resistances are satisfactory at all process conditions.

  • PDF

Formation and Removal of Trihalomethanes based on Characterization of Hydrophobic and Hydrophilic Precursors (전구물질의 소수성 및 친수성 특성에 따른 트리할로메탄의 생성과 제거에 관한 연구)

  • Jeon, Heekyung;Kim, Junsung;Choi, Yoonchan;Choi, Haeyeon;Chung, Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.123-128
    • /
    • 2008
  • The Dissolved Organic Carbon (DOC) existing in a water includes both hydrophobic and hydrophilic substances however, most of the discussion focuses on hydrophobic substances. The hydrophobic fraction was easily removed by absorption or coagulation more than hydrophilic fraction. Therefore, control of the hydrophilic fraction is very important in water treatment process. This study is to determine the variation of DOC, the removal efficiency of DOC, and Trihalomethane formation potential (THMFP) after each stage of water treatment process by fractionating Natural Organic Matters (NOM) into hydrophobic and hydrophilic substance. DOC from raw water was fractionated at acidic pH (pH<2) using XAD 8 resin column, into two fraction : hydrophobic substance (i.e. humic substance) adsorbed on XAD 8 and hydrophilic substance which represent the organics contained in the final effluent. THMFP was carried out according to the following set condition: Cl2/DOC=4 mg/mg, incubation at $25^{\circ}C$ in darkness, pH 7 adjust with HCl or NaOH as necessary, and 72hour-contact time. THMs analyzed in this study were chloroform, bromodichloromethane, dibromochloromethan, and bromoform. Sewage was almost evenly split between the hydrophobic (56%) and hydrophilic fraction (44%). But, Aldrich humic substance (AHS) was found to contain less hydrophilics (14%) than hydrophobics (86%). The formation of THMs may depend on the source which is characterized by the composition of organic matters such as AHS and sewage. The THMFP yield of sewage and AHS were assessed as follows. The value of the THMFP reaction yield, AHS $172.65{\mu}g/mg$, is much higher than that of sewage $41.68{\mu}g/mg$. This illustrates possible significant difference in THMFP according to the component type and the proportion of organic matter existing in water source. Apparently AHS react with chlorine to produce more THMFP than do the smaller molecules found in sewage. Water treatment process may reduce THMFP, nevertheless residual DOC (the more hydrophilic substance) has significant THMFP. Further reduction in organic halide precursors requires application of alternative treatment techniques.

Stress of the Pediatric Patient′s Parent in the Emergency Department (응급의료센터에 내원한 환아부모의 스트레스)

  • Park In-Sook;Lee Nam-Hyeong
    • Child Health Nursing Research
    • /
    • v.8 no.3
    • /
    • pp.260-271
    • /
    • 2002
  • This study was performed to identify the level of stress recognized by the parents as a support system for their infant patients who were hospitalized in an emergency department, thus to provide the resulting data as the basic material of care intervention for the families of infant patients. This study subjected the parents with infant patients who were hospitalized in emergency department of C University Hospital in Daejeon, and the data was collected from questionnaires for them, dating from Mar. 20, to Jun. 24, 2001 This study used the tool(30 questions) which was originally developed by Ji, Dong-ok (1992) for measuring the stress of families of infant patients in emergency room, and then was modified and complemented by this researcher suitably for infant patients. Collected data was statistically analyzed with frequency, percentage, mean, standard deviation, t-test, ANOVA, by using SPSS WIN10.0 program, and the results were as follows: 1. The stress of parents with infant patients hospitalized in emergency department averaged 3.31 on the basis of 5-point measure, which means that they felt stress beyond means. 2. The factor with high average out of stress factors the parents of infant patients recognized included the followings: 'about the pain of infant patients due to examination(3.91±1.00)'; 'about rare opportunity to be in contact with physician(3.78±1.09)'; 'delay in emergent treatment required for infant patients(3.75±1.31)'; 'delay in the general treatment of infant patients(3.72±1.32)'. Factors of the stress level includes the followings: 'care and medical treatment'(3.46±.72); 'body and diseases'(3.41±.97)'; 'lack of information and supportable resources (3.25±.77)'; and so on. 3. For the stress level according to general characteristics, there were statistically significant differences in the result of the condition of infant patients, medical treatment(P<.01), religion, the procedure of treatment(P<.05). With little preceding studies for infant patients hospitalized in emergency department, this study looked through the level of stress recognized by the parents of infant patients. Based on the comprehension on the parents with infant patients and the knowledge on stress factors recognized by the parents, it is expected that we can seek the methods of care intervention such as explanation of care and treatment procedures, unit policies, continuous interest and emotional supports as well as the provision of information to understand the responses of parents and reduce accompanied stresses.

  • PDF

Characteristic of Permeability with the Sand, Calcium Bentonite and Solidifier Mixtures according to Selective Reaction of TCE (트리클로로에틸렌(TCE) 선택적 반응에 따른 모래, 칼슘-벤토나이트 및 겔화제 혼합차수물의 투수 특성)

  • Yun, Seong Yeol;Choi, Jeong Woo;Oh, Minah;Lee, Jai-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • To improvement the swelling characteristics of the existing cutoff wall against the moisture, the permeability of the sand, calcium bentonite and solidifier mixture according to the contact with trichloroethylene (TCE) was evaluated. Characteristics analysis and the permeability test of the research materials were performed. The permeability was decreased as the mixing ratio of the calcium bentonite was increased and it was increased as the mixing ratio of the solidifier was increased. In conclusion, when mixing 15% of calcium bentonite and more than 30% of solidifier, the permeability coefficient in the underground water movement was analyzed as more than α × 10-4 cm/sec showing that it does not block the underground water movement. In addition, as the permeability coefficient of mixtures after TCE reaction was analyzed as less than α ×10-7 cm/sec, it satisfied the condition of blocking layer (less than 1.0 × 10-6 cm/sec). Therefore, the calcium bentonite and solidifier can be utilized as barrier that showing the characteristic of percolation ability conversion in soil and underground water contaminated with TCE.

Numerical analysis for heat transfer and pressure drop characteristics of (다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석)

  • Hou, Rong-Rong;Park, Hyeong-Seon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.367-375
    • /
    • 2014
  • In numbers of kinds of heat exchanger, the shell-tube heat exchanger is the most commonly used type of heat exchanger in the industry field. In order to improve the thermal performance of the heat exchanger, this study was analyzed heat transfer characteristics according to arrangement of baffle and direction of baffle and bump phase of baffle about shell-tube heat exchanger using appropriate SST (Shear Stress Transport) turbulence model for flow separation and boundary layer analysis. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature of shell side was constantly 344 K and the variation of the water flow rate was 6, 12, 18 and 24 l/min. As the result of analysis, zigzag baffle arrangement enhances heat transfer rate and pressure drop. Furthermore, in the direction of the baffle, heat transfer rate is more improved with vertical type and angle $45^{\circ}$ type than existing type, and pressure drop was little difference. Also, the bump shape of baffle surface contributes to heat transfer rate and pressure drop improvement due to the increased heat transfer area. Through analysis results, we knew that the increase of the heat transfer was influenced by flow separation, fluid residual time, contact area with the tube, flow rate, swirl and so on.

The Study on the Slurry Wear Behavior of Rubber Vulcanizates (고무 소재의 슬러리 마모 거동에 관한 연구)

  • Chung, Kyung-Ho;Hong, Young-Keun;Park, Moon-Soo
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.70-77
    • /
    • 2011
  • A new piece of test equipment, the slurry wear tester (SWT), was proposed in this study to evaluate the wear behavior of rubber vulcanizate in environmental contact with slurry. Natural rubber (NR) and chloroprene rubber (CR) were chosen as the basic matrices to test the slurry wear. The fluids used to fill the chamber of the SWT were 35% HCl and NaCl solution. The Akron abrasion test was used for comparison with SWT. According to the results of the Akron abrasion test, CR vulcanizate abraded more rapidly than NR vulcanizate under same test condition. It was found that the hysteresis of rubber was key factor contribute to the wear behavior. However, the slurry wear rate of the NR and CR vulcanizates did not change significantly, even with changes in the concentration of acid and the immersion time in both HCl and NaCl solutions; the fluid decreased the friction between the abrasive paper and the specimen. It also reduced the heat generated from repeated deformation and wear debris at the surface of the SWT's abrasion arm. Thus, these phenomena affected the wear behavior of rubber vulcanizate and caused different results in the conventional Akron abrasion test. This outcome could have resulted in an incorrect analysis if the slurry wear behavior of the rubber vulcanizate was estimated by the conventional abrasion tests, which are operated under dry conditions.

A Biocompatibility Evaluation of Hydroxyapaite·Titania Surface for Dental Implant (임플란트 적용을 위한 하이드록시아파타이트·이산화티탄 표면의 생체적합성 평가)

  • Kang, Min-Kyung;Bae, Sung-Suk
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.70-76
    • /
    • 2016
  • The objective of this study was to fabricate hydroxyapatite (HA) containing titania layer by HA blasting and anodization method to obtain advantages of both methods and evaluated biocompatibility. To fabricate the HA containing titania layer on titanium, HA blasting treatment was performed followed by microarc oxidation (MAO) using the electrolyte solution of 0.04 M ${\beta}$-glycerol phosphate disodium salt n-hydrate and 0.4 M calcium acetate n-hydrate on the condition of various applied voltages (100, 150, 200, 250 V) for 3 minutes. The experimental group was divided according to the surface treatment procedure: SM (simple machined polishing treatment), HA, MAO, HA+MAO 100, HA+MAO 150, HA+MAO 200, HA+MAO 250. The wettability of surface was observed by contact angle measurement. Biocompatibility was evaluated by cell adhesion, and cell differentiation including alkaline phosphatase activity and calcium concentration with MC3T3-E1 cells. The porous titanium oxide containing HA was formed at 150 and 200 V. These surfaces had a more hydrophilic characteristic. Biocompatibility was demonstrated that HA titania composite layer on titanium showed enhanced cell adhesion, and cell differentiation. Therefore, these results suggested that HA containing titania layer on titanium was improved biological properties that could be applied as material for dental implant system.