• Title/Summary/Keyword: Contact condition

Search Result 1,537, Processing Time 0.032 seconds

Slaking, Swelling and Shear Strength Characteristics of Pohang Mudrocks (포항이암층의 Slaking, 팽창 및 전단강도특성)

  • 이영휘
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.33-42
    • /
    • 1996
  • The weathering of mudrock in the Pohang area is mainly caused by slaking and swelling when the mudrock is absorbed with water. In this regard, this paper chows the results of chemical analysis and the identification of rock-forming minerals from XRD. It also compares the slaking and swelling characteristics of mudrocks sampled from 3 different sites. The chief rock -forming minerals are the quartz, and the several types of clay minerals. The slake durability indices are ranged from 71% to 96%, and these values are closely related to the liquid limit of the powdered nock specimen. In a similar manner to the slaking characteristics the greatest values of the swelling pressure and the swelling strain were measured from the mudrock specimen with the highest value of liquid limit. The greatest measured values of the swelling pressure and the swelling strain are 9.4 kg 1 cm2 and 33.5% respectively. The residual sheer strength of mudrock decreases as the number of wet -diy cycles increases, and the residual strength at 5 cycles are measured to c,=0.24kg/cm2 and p,=28$^{\circ}$. The lowest residual strength is measured at the fresh rock -rock contact surface in the moist condition of which values are cr: 0 and n,: 21.5$^{\circ}$.

  • PDF

An Estimation of the Fatigue Behavior on the Cruciform Type Specimen by Variation of the Stress Ratio (응력비 변화에 따른 십자형 접합부의 피로거동 평가)

  • 김태봉;서상구;우상익
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.140-145
    • /
    • 2000
  • This paper was composed with fatigue test of the cruciform specimens, as load carrying and non-load carrying type. It also has performed computational analyses for geometric condition of the fillet welding bead. As test results, the effect of stress ratio in the specimen was insignificant. Stress ranges were varied with R=0.1~0.2. The fatigue cracks that were found in the load carrying type specimens and most specimens welded with contact were developed at the end of welds. The fatigue strength of specimen that have fractured in maternal plate was found about ${\Delta}\sigma_c$=63.5MPa. It's about 24% less than that of the non-load carrying type specimens having about ${\Delta}\sigma_c$=83.8MPa. A category of the Fatigue design specifications which provide for cruciform details was defined grade C as a stress of the maternal member. And then, the fatigue strength to be transformed into the maternal stress was found about 78.27 MPa, it tends to be less than that of allowable fatigue strength.

  • PDF

A Study on Strength Prediction of Mechanical Joint of Composite under Bending Load (굽힘 하중을 받는 복합재 기계적 체결부의 강도예측에 관한 연구)

  • Baek, Seol;Kang, Kyung-Tak;Lee, Jina;Chun, Heoung-Jae
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.213-218
    • /
    • 2014
  • This paper predicted the strength of mechanical joint of composites under bending load by means of the characteristic curve method. The method has been employed only for tensile and compression load conditions, but in this study, this method was extended to the bending load condition. For the finite element analysis (FEA), the nonlinear analysis was conducted considering the contact and friction effects between composite material and pin. The failure strength and mode on characteristic curve were evaluate with Tsai-Wu failure theory. To validate the results of FEA, the experiments were conducted to find out the failure load by applying bending moment on the composite specimens. The results showed reasonable agreements with theoretical results. These results lead to a conclusion that the characteristic curve method can be applied to predict the bending strength of mechanical joint of composites.

A Study on the Spontaneous Ignition of the Fuel Injected into a Hot Air Stream - Additional Report: Utilization of Diesel Oil and Emulsified Fuel- (高溫空氣流 에 噴射한 噴霧 의 自然燃燒 에 관한 硏究 -속보 : 경유 및 유화핵연료 사용-)

  • 방중철;태전간랑
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.627-637
    • /
    • 1985
  • The combustion process and the performance of a diesel engine are seriously affected by the ignition delay period of the fuel used. Some methods for improving the combustion process in the engine cylinder are to well match the strength of air swirl with the space of sprays in the cylinder, to blend an ignition improver in the fuel, to inject a small amount of auxiliary fuel prior to main injection and so on. Recently, the improvement of fuel economy and the reduction of exhaust smoke and NO have been successfully achieved by supplying diesel engines with emulsified fuel. However, it is very difficult to know real combustion mechanism under such special conditions, because of many factors affecting on the combustion process in practical reciprocating engine. In the present paper, the combustion processes of diesel fuel and emulsion fuel were tried to improve and to observe by making contact with various lean pre-mixtures in the hot air stream duct. This hot air stream method has an advantage that the spontaneous combustion process can be observed under a simplified condition.

Co-Embedded Graphitic Porous Carbon Nanofibers for Pt-Free Counter Electrode in Dye-Sensitized Solar Cells (염료감응형 태양전지의 비백금 상대전극을 위한 Co가 내재된 Graphitic 다공성 탄소나노섬유)

  • An, Hye Lan;Kang, Hye-Rhin;Sun, Hyo Jeong;Han, Ji Ho;Ahn, Hyo-Jin
    • Korean Journal of Materials Research
    • /
    • v.25 no.12
    • /
    • pp.672-677
    • /
    • 2015
  • Co-embedded graphitic porous carbon nanofibers(Co-GPCNFs) are synthesized by using an electrospinning method. Their morphological, structural, electrochemical, and photovoltaic properties are investigated. To obtain the optimum condition of Co-GPCNFs for dye-sensitized solar cells(DSSCs), the amount of cobalt precursor in an electrospinning solutuion are controlled to be 0 wt%(conventional CNFs), 1 wt%(sample A), and 3 wt%(sample B). Among them, sample B exhibited a high degree of graphitization and porous structure compared to conventional CNFs and sample A, which result in the performance improvement of DSSCs. Therefore, sample B showed a high current density(JSC, $12.88mA/cm^2$) and excellent power conversion efficiency(PCE, 5.33 %) than those of conventional CNFs($12.00mA/cm^2$, 3.78 %). This result can be explained by combined effects of the increased contact area between the electrode and elecytolyte caused by improved porosity and the increased conductivity caused by the formation of a high degree of graphitization. Thus, the Co-GPCNFs may be used as a promising alternative of Pt-free counter electrode in DSSCs.

A Fundamental Study for Development on Waterproof and Flame Retardant processing technology the Interior Wood of using Induced electricity heating Microwave (유전가열 마이크로파를 적용한 방수·방염 내장목재 개발을 위한 기초적 연구)

  • Park, Cheul-Woo;Heo, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.35-41
    • /
    • 2008
  • Qualitative enhancement of dwelling life has changing the recognition for the environment friendly wood which is being highlighted for its usage as an interior materials. This trend may prove the excellent performance of wood whose inherent characteristics has its comfortable, mild feeling of material, sound resistance and stabilities and the market of interior woods including floor, moulding and wooden panel as finishing interior materials is growing sustainably. However, since this materials is vulnerable to humidity and flame, waterproofing and flame retarding stability, an essential condition for interior materials, together with maintenance, are the main topics to be resolved. From the above-mentioned results, as a result of waterdrop contact angle, wood absorption volume and water content percentage test and the performance test of the processed materials after flame retardant, though there was some submerging time changes among types of woods for ensuring waterproofing performance improvement but as time passes, similar tendency was noticed to be formulated. As the submerging time is increased, so does the absorption volume and accordingly optimal level of range is judged to be drawn in order to ensure excellent performance, taking optimal economy into consideration. Therefore, it is considered that above-mentioned woods could be utilized for waterproof and flame retardant processed interior materials using uniform microwave and in order to put this technology into practical application, a research by way of diversified performance proving is required to be carried out.

  • PDF

A Technique of Measuring Leadwire-Site for Automatic Leadwire Cutting Machines (리드선 자동절단기를 위한 리드선 위치측정법)

  • ;Seiichi Noguchi;Koei Igarashi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.1
    • /
    • pp.120-130
    • /
    • 1994
  • The leadwire cutting machine that has been used recently cuts leadwires by putting one-side force with the same priciple as a saw, and applies a stress at soldered part of PCB. Because the stress becomes one cause of contact-defect, a leadwire cutting robot that cuts leadwire-site with nipper and does not apply stress is considered, In this paper a technique of detecting leadwire-site is studied for the purpose of using on automatic leadwire cutting robots. A technique deriving 2-dimensional site-information with many I-dimensional binary data of perspective front-view of PCB taken from various direction was proposed. Simulation and experiments were done under the same condition each other and a small universal PCB was choosen as an experimental object. As a result of simulations and experiments, the proposed technique turns out to be very useful for automatic leadwire cutting robots.

  • PDF

Electrical and Optical Properties with the Thickness of Cu(lnGa)$Se_2$ Absorber Layer (Cu(InGa)$Se_2$ 광흡수막의 두께에 따른 태양전지의 전기광학 특성)

  • Kim, S.K.;Lee, J.C.;Kang, K.H.;Yoon, K.H.;Park, I.J.;Song, J.;Han, S.O.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.108-111
    • /
    • 2002
  • CIGS film has been fabricated on soda-lime glass, which is coated with Mo film. by multi-source evaporation process. The films has been prepared with thickness of 1.0 ${\mu}m$, 1.75${\mu}m$, 2.0${\mu}m$, 2.3${\mu}m$, and 3.0${\mu}m$. X-ray diffraction analysis with film thickness shows that CIGS films exhibit a strong (112) preferred orientation. Furthermore. CIGS films exhibited distinctly decreasing the full width of half-maximum and (112) preferred peak with film thickness. Also, The film's microstructure, such as the preferred orientation, the full width at half-maximum(FWHM), and the interplanar spacing were examined by X-ray diffraction. The preparation condition and the characteristics of the unit layers were as followings ; Mo back contact DC sputter, CIGS absorber layer : three-stage coevaporation, CdS buffer layer : chemical bath deposition, ZnO window layer : RF sputtering, $MgF_2$ antireflectance : E-gun evaporation

  • PDF

Analysis of Dynamically Penetrating Anchor based on Coupled Eulerian-Lagrangian (CEL) Method (Coupled Eulerian-Lagrangian (CEL) 방법을 이용한 Dynamically Penetrating Anchor의 동적 거동 분석)

  • Kim, Youngho;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.895-906
    • /
    • 2014
  • A fundamental study of the dynamically penetrating anchor (DPA - colloquially known as torpedo anchor) embedded into deep seabed was conducted using measurement data and numerical approaches. Numerical simulation of such a structure penetration was often suffered by severe mesh distortion arising from very large soil deformation, complex contact condition and nonlinear soil behavior. In recent years, a Coupled Eulerian-Lagrangian method (CEL) has been used to solve geomechanical boundary value problems involving large deformations. In this study, 3D finite element analyses using the CEL formulation are carried out to simulate the construction process of dynamic anchors. Through comparisons with results of field measurements, the CEL method in the present study is in good agreement with the general trend observed by in-situ measurements and thus, predicts a realistic large deformation movement for the dynamic anchors by free-fall dropping, which the conventional FE method cannot. Additionally, the appropriate parametric studies needed for verifying the characteristic of dynamic anchor are also discussed.

Mating and Incidental Activities of Ram (Ovis aries) When Exposed to Ewe(s) and Competitor Ram in Pen Mating Condition

  • Patel, M.;Das, N.;Pandey, H.N.;Yadav, M.C.;Girish, P.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.4
    • /
    • pp.463-469
    • /
    • 2005
  • An attempt was made to analyze the factors affecting mating performance of rams in pen mating systems. Due to many types of social interactions, mating performance of rams may decrease or increase. Six intact Muzaffarnagari rams were used and divided into three dominant subordinate pairs by food and ewe competition test. For dominant rams subordinate ram became competitor and vice versa. In the first experiment, ram was exposed to ewe but the competitor ram was kept outside the pen with the facility of visibility only. In the second experiment each ram was exposed to ewe along with the competitor ram and in third experiment ram was exposed to ewes (two) along with competitor ram in observation pen. Recordings of different mating and agonistic behaviour were done in all the experiments. It was found that subordinate ram's mating behaviour was inhibited by mere presence of a dominant ram out side without physical contact. However, when ram exposed to oestrus ewe(s) along with competitor ram, both dominant and subordinate rams spent much of their time in guarding activities instead of mating. In addition dominant ram tried to curtail the subordinate ram mating by agonistic interaction like fight and butting. Different guarding activities were observed either as active or passive type depending on level of dominanace. It was concluded that in a limited space the interaction of two or more rams might affect the number of services adversely.