• Title/Summary/Keyword: Contact b.c

Search Result 325, Processing Time 0.034 seconds

INFLUENCE OF CENTRAL PANORAMIC CURVE DEVIATION ON THE MANDIBULAR IMAGE RECONSTRUCTION IN THE IMPLANT CT (임플랜트전산화단층촬영시 CENTRAL PANORAMIC CURVE의 변화가 하악골의 영상 재구성에 미치는 영향)

  • Park Rae-Jeong;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.47-58
    • /
    • 1998
  • The purpose of this study was to investigate an influence of the change of central panoramic curves on the image reconstruction in the dental implant CT. The author designed three experimental groups according to the location of central panoramic curve. In group A, central panoramic curve was determined as the curve connecting the center of roots from the first premolar to the first molar. In group B, central panoramic curve was determined as the line connecting the lingual cortical plate at the level of the mesial aspect of the first premolar with the buccal cortical plate at the level of the mesial aspect of the first molar. In Group C, central panoramic curve was determined as the line connecting the buccal cortical plate at the level of the mesial aspect of the first premolar with the lingual cortical plate at the level of the mesial aspect of the first molar. Twenty four reformatted CT images was acquired from four mandibles embedded in the resin block and twenty four contact radiographs of dog specimens were acquired. Each Image was processed under Adobe Photoshop program analysed by MSPA(mandible/maxilla shape pattern analysis) variables such as MXVD, MXHD, UHD, MHD, and LHD. The obtained results were as follows ; 1. The mean of MXVD variable was 19.9, 20.2, and 20.0 in group A, B, and C, respectively, which were smaller than actual value 20.5. But, there was no significant difference among 3 groups (p>0.05). 2. The mean of MXHD, UHD, MHD, and LHD variables in group A, B, and C was 11.9, 12.2, and 12.3; 9.3, 9.5, and 9.6; 10.0, 10.3, and 10.3; 9.2, 9.3, and 9.4 respectively which were equal to or greater than the actual value 11.8, 9.3, 10.0, and 9.2. But, there was no significant difference among 3 groups (p>0.05). 3. The number of noneffective observations with difference over or under 1 mm with comparison to the actual value was 24(20%), 58(48.3%), and 52(43.3%), respectively, in group A, B, and C. 4. In group A, the number of observations over 1 mm and under 1 mm was 9 and 15, respectively, but in group Band C, the number of observations over 1 mm was more than under 1 mm.

  • PDF

Application of Biological Activated Carbon Process for Water Quality Improvement of Stagnant Stream Channels

  • Lee, Jae-Ho;Park, Jeung-Jin;Park, Tae-Joo;Byun, Im-Gyu
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.309-316
    • /
    • 2014
  • The water quality improvement of golf course ponds, as representative stagnant stream channels, was evaluated by applying a biological activated carbon (BAC) process composed of four consecutive activated carbon reactors. The study was performed from autumn to winter in order to evaluate the feasibility of the BAC process under low temperature conditions. In the study, water quality of pond A (target pond) and pond B (reference pond) were monitored. Pond water was pumped into the BAC process, and was then returned to the pond after treatment. The optimal conditions were determined to be 2 hr of empty bed contact time (EBCT) at a temperature above $4^{\circ}C$, in which improvements of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) of pond A compared to pond B were 3.62%, 3.48% and 1.81%, respectively. On the other hand, as the temperature was below $4^{\circ}C$, some degree of water quality improvement was achieved even when EBCT were 1 or 0.5 hr, suggesting that the BAC process can be successfully applied for the improvement of pond water quality in winter months. The values of biomass concentration and microorganism activity in each condition were highest where 2 hr of EBCT was applied at a temperature above $4^{\circ}C$, but values were similar throughout all treatment conditions, and thus, adsorption is considered to be the dominant factor affecting process efficiency. From the denaturing gel gradient electrophoresis (DGGE) results, no significant differences were observed among the activated carbon reactors, suggesting that the number of reactors in the system could be decreased for a more compact application of the system.

The Change of Blink Rate by Wearing Soft Contact Lens (소프트콘택트렌즈 착용에 의한 순목 횟수 변화)

  • Lee, Youn-Jin;Park, Sang-Il;Lee, Heum-Sook;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.173-179
    • /
    • 2006
  • We investigated the change of the blink rate by wearing soft contact lens(SCL). Eight types of soft contact lenses were worn by twelve asymptomatic contact lens wearers. When wearers were worn SCLs for 15 min, the average blink rate was 20.0 blinks/min, which was a statistically significant increase compared to 13.3 blinks/min, the average blink rate of non-SCL-worn eye. After 8 hr of lens wear, the average blink rate was 24.3 blinks/min, and it was 11 blinks/min more than that of non-SCL-worn eye and 4 blinks/min more than that of 15 min SCL-worn eye. There were a little difference of the blink rate in types of lens, which the blink rate range of all lens after 15 min of lens wear was 18.1~20.9 blinks/min and that after 8 hr of lens wear was 22.9~24.9 blinks/min. When wearing A lens(vifilcon, 0.06 mm) having thin center thickness, wearers showing difference of 10.0~11.9 blinks/min between non-SCL-worn eye and 15 min SCL-worn eye reached 16.7% and it was more than that of relatively thick B lens(0.17 mm) and C lens(0.14 mm). This result suggest that the center thickness was not unique factor of the blink rate change and other factors would have synthetically influence on the blink rate change. In the case of B lens and C lens of hilafilcon material but having different center thickness and water content, wearers increasing more than 4.0 blinks/min after 8 hr of lens wear was 58.3% and 41.7%, respectively. This result have provided information that the lenses of similar materials but different center thickness and water content could cause individually the different change of the blink rate.

  • PDF

Development of intermediate roll which has a long life for cold rolling mills (냉간압연용 장수명 중간롤 개발)

  • Park Y. C.;Kim B. H.;Kim I. B.;Kim J. T.;KIM H. M.;Lee W. D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.207-215
    • /
    • 2004
  • There are various characteristics called for in work roll and intermediate rolls for cold rolling mills. Among these characteristics, the two main requirements are to ensure the quality of the rolled products and to reduce roll cost. To achieve these needs, resistance to wear, to thermal shock and to contact fatigue are especially important. This paper describes that new material(named DSR1) for intermediate rolls which greatly increases rolling campaign and improves resistance to wear has been developed. DSR1 was successfully manufactured and has been used in the cold rolling mill. It showed that Trial product was homogenous in hardness distribution and sufficient usable diameter. Also in service test, trial product is much more excellent rolling performance than conventional $5\%Cr$.

  • PDF

An Analysis on Volumetric Displacement of Gerotor Pump/Motor Using Vane Length (회전날개 길이를 이용한 제로터 펌프/모터의 배제용적에 관한 연구)

  • Kim, S.D.;Kim, D.M.;Ham, Y.B.;Han, C.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.8-16
    • /
    • 2011
  • It is hard and complicated to analytically derive the volumetric-displacement formula of a gerotor pump/motor. Analytical formulas for calculating the volumetric-displacement are derived in this work, which is relatively easy and based upon vane lengths. The vane lengths mean the distances from axis of inner rotor or outer rotor to contact points between inner and outer rotors. Two kinds of formula were studied for two different kinematic motions of rotors. The first one is the case that outer rotor is fixed in space and inner rotor is in mixed motion of planetary revolution and rotation with respect to the spinning axis. And the second is the case that both inner and outer rotors simultaneously rotate. The proposed formula is verified through comparison with volumetric-displacement obtained from numerical CAD calculation.

A study of 10.5 GHz band Doppler radar for non-contact type hydrometer (비접촉식 유속계를 위한 10.5 GHz 대역 도플러 레이더에 대한 연구)

  • Kim, Jin-Su;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.139-144
    • /
    • 2009
  • A Doppler radar is a radar using the doppler effect of the returned echoes from targets to measure their radial velocity. To be more specific the microwave signal sent by the radar antenna's directional beam is reflected toward the radar and compared in frequency, up or down from the original signal, allowing for the direct and highly accurate measurement of target velocity component in the direction of the beam. In this paper, we designed the doppler radar composed of 10.5 GHz band DROs(Dielectric Resonator Oscillator), $90^{\circ}C$ branch line coupler, single balanced mixer and $4{\times}4$ array antenna of high gain, high directivity, for non-contact type hydrometer. Fabricated Doppler radar can detect slow moving objects.

  • PDF

A RADOIOGIC STUDY OF THE TEETH RESORPTION IN THE AREA OF A AMELOBLASTOMA (법랑아세포종과 관련된 치근흡수에 관한 방사선학적 연구)

  • Yee Choon Aei
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-33
    • /
    • 1980
  • An ameloblastoma produces more extensive resorption of the teeth on which it encroaches than do most of the other lesions. In this study, intraoral and extraoral radiographs of 78 cases of ameloblastoma were observed and the root resorption associated with ameloblastoma was classified into four types of resorption. With these, the following conclusions were obtained. 1. The root resorption was observed in 72 cases of ameloblastoma. (92.3%) 2. In the aspect of resorptive changes of 424 roots observed, 342 roots showed smooth resorption. (80.6%) 3. The 424 roots associated with ameloblastoma revealed the following radiographic features. a) Root apex resorption in contact with the lesion appeared in 189 roots. (44.5%) b) The resorption of roots projected into the lesion appeared in 147 roots. (34.6%) c) Slight resorption of root surface in contact with the lesion was observed in 56 roots. (13.2%) d) Loss of lamina dura and periodontal space without root resorption were observed in 32 roots. (7.7%)

  • PDF

Stability Enhancement of Polysilicon Thin-Film Transistors with A Source-tied-to-body

  • Choi, B.D.;Choi, D.C.;Jung, J.Y.;Park, H.H.;Chung, H.K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.293-293
    • /
    • 2005
  • The differences between floating and grounded body effects in polycrystalline silicon thin-film transistors (polysilicon TFTs) are investigated by making a body contact. The floating body effects such as kink effect, subthreshold slope change, and body current characteristics are explained and modeled by impact ionization, which causes source body turn on, and activates the parasitic bipolar junction transistors (BJTs). These effects become crucial for channel lengths of 4㎛ or shorter. Our data show that making a body contact reduces kink effects significantly and identifies impact ionization mechanism in polysilicon TFTs.

  • PDF

On the Optimum Modelization for a Spray Column Direct Contact Heat Exchanger (분사칼럼식 직접접촉 열교환기의 최적 모델링을 위한 연구)

  • Yoon, S.M.;Kang, Y.H.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1991
  • The purpose of this study is to lay groundwork for a complete analysis of two component flow by analyzing a single component flow made of continuous fluid without dispersed phase. In order to achieve uniform velocity distributions which are desirable in designing an optimum spray column direct contact heat exchanger, the influence of injection nozzle orientation has been investigated for axial and radial injections. The results that radial injection ensures more uniform velocity distributions compared to the axial case. The flow characteristics in a spray column have been investigated with various L/D values and inlet velocities, the most uniform internal velocity distributions have been obtained for the case of L/D=10 and 0.1m/sec. In the present investigation, it is shown that radial injection method for the continuous flow is advantageous in obtaining desirable uniform velocity distributions in a spray column. It is also found that as the value of L/D increases and the inlet velocity decreases, the flow improves to be better uniform velocity distributions.

  • PDF