• Title/Summary/Keyword: Contact Treatment

Search Result 1,605, Processing Time 0.03 seconds

Treatment of Contact between Roll/Roll and Roll/Strip for Rolling Process Simulation (압연공정해석을 위한 판과 롤의 접촉 경계면 처리)

  • 김태효;황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.156-159
    • /
    • 2003
  • Surface normal vector and surface velocity are very important parameters to simulate rolling processes precisely. In this study, Local displacement functions are constructed for each node on the contact surface and parameters are found by the least square fitting of displacement on the neighbor nodes. Deformation gradient tensor is calculated from the displacement function and surface normal vector and velocity also can be derived. Flat rolling simulation model is presented on the basis of the suggested contact scheme. Series of rolling process simulation are carried out and the results are compared with the experiments.

  • PDF

Symmetrically loaded beam on a two-parameter tensionless foundation

  • Celep, Z.;Demir, F.
    • Structural Engineering and Mechanics
    • /
    • v.27 no.5
    • /
    • pp.555-574
    • /
    • 2007
  • Static response of an elastic beam on a two-parameter tensionless foundation is investigated by assuming that the beam is symmetrically subjected to a uniformly distributed load and concentrated edge loads. Governing equations of the problem are obtained and solved by pointing out that a concentrated edge foundation reaction in addition to a continuous foundation reaction along the beam axis in the case of complete contact and a discontinuity in the foundation reactions in the case of partial contact come into being as a direct result of the two-parameter foundation model. The numerical solution of the complete contact problem is straightforward. However, it is shown that the problem displays a highly non-linear character when the beam lifts off from the foundation. Numerical treatment of the governing equations is accomplished by adopting an iterative process to establish the contact length. Results are presented in figures to demonstrate the linear and non-linear behavior of the beam-foundation system for various values of the parameters of the problem comparatively.

A Novel Non-contact Heart Rate Estimation Algorithm and System with User Identification

  • Kim, Chan-Il;Kim, Hyung-Jin;Kim, Seon-Chil;Park, Hee-Jun;Lee, Jong-ha
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.6
    • /
    • pp.395-402
    • /
    • 2016
  • In these days, the wearable devices have been developed for measuring biological data effectively. However, wearable devices have tissue allege and noise problem. Also, it is impossible for a remote center to identify the person whose data are measured by wearable devices, which could trigger a communication problem over treatment. To solve these problems, biometric measurement based on a non-contact method, such as face image sequencing is necessary. This makes it possible to measure biometric data without any operation and side effects. This system can monitor the biological signals of people in real time without allege and noise and simultaneously identify them. In this paper, we propose an authentication process while measuring biometric data, through a non-contact method.

The Effect of Contact Resistance and Electric Conductivity on PEMFC Performance (접촉저항 및 전기전도도가 연료전지 성능에 미치는 영향)

  • Kim, Ki-Jung;Yun, Yong-Sik;Jeon, Yu-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.133-136
    • /
    • 2007
  • In this work, 3-dimensional, non-isothermal numerical simulation was performed to analyse the effects of contact resistance and electric conductivity of GDL on the fuel cell performance. For numerical simulation contact resistance of Carbon and Stainless steel was measured. The simulation results reveal that 10 times change of electric conductivity leads only 6.5% decrease of PEMFC performance. But stainless steel which has high contact resistance decrease fuel cell performance over 25% at a high current density region than carbon. This results show that suitable Surface treatment technology is needed for metal bipolar plate, especially stainless steel.

  • PDF

Wear and Fatigue Properties of Surface-Hardened Rail Material (표면 강화처리 레일의 마모 및 피로 특성)

  • Chang, Seky;Pyun, Young-Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.5
    • /
    • pp.380-385
    • /
    • 2016
  • Railway tracks are repeatedly overstressed and damaged owing to increase in passing tonnage and numerous contact cycles between wheels of train and rails. In order to ensure safe train operation, heat-treated rails are used in addition to regular inspection and maintenance of these rails. Normal rails were treated using ultrasonic nanocrystal surface modification (UNSM) to strengthen the surface of rails. A few changes in surface properties were detected with respect to hardness and compressive residual stress after UNSM treatment. Wear and rolling contact fatigue tests were performed using rails whose surfaces were hardened by UNSM and heat-treated rails. The amount of wear and fatigue life cycles were measured to estimate the effect of UNSM on the rail material. The material of the surfacehardened rail showed improved wear and rolling contact fatigue properties.

Controlled Plasma Treatment for Edge Contacts of Graphene (그래핀의 엣지 접합 (Edge Contact)을 위한 플라즈마 처리 연구)

  • Yue, Dewu;Ra, Chang-Ho;Liu, Xiaochi;Daeyeong, Daeyeong;Yu, Won-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.293-293
    • /
    • 2014
  • The applicability of graphene has been demonstrated in the electronic fields. But, high performance of graphene is limited by the contact resistance (Rc) at the metal-graphene interface. Recently, Rc was found to be improved by forming edge-contacted graphene via theoretical simulation. Based on the differences between the surface and edge contacts at the M-G interface, we demonstrate "edge-contacted" graphene through the use of a controlled plasma processing technique that generates the edge structure of the bond and significantly reduces the contact resistance. The contact resistance attained by using pre-plasma processing was of $270{\Omega}{\cdot}{\mu}m$. Mechanisms of pre-plasma process leading to low Rc was revealed by SEM and Raman spectroscopy. In the end, controlled pre-plasma processing enabled to fabricate CVD-graphene field effect transistors with an enhanced adhesion and improved carrier mobility.

  • PDF

The Effect of Contact Resistance and Electric Conductivity on PEMFC Performance (접촉저항 및 전기전도도가 연료전지 성능에 미치는 영향)

  • Kim, Gi-Jeong;Yun, Yong-Sik;Jeon, Yu-Taek
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.184-186
    • /
    • 2012
  • In this work, 3-dimensional, non-isothermal numerical simulation was performed to analyse the effects of contact resistance and electric conductivity of GDL on the fuel cell performance. For numerical simulation contact resistance of Carbon and Stainless steel was measured. The simulation results reveal that 10 times change of electric conductivity leads only 6.5% decrease of PEMFC performance. But stainless steel which has high contact resistance decrease fuel cell performance over 25% at a high current density region than carbon. This results show that suitable Surface treatment technology is needed for metal bipolar plate, especially stainless steel.

  • PDF

Surgical Treatment of Vocal Cord Granuloma (성대돌기 육아종의 수술적 치료)

  • Yu, Myeong-Sang;Song, Hyung-Min;Roh, Jong-Lyel;Choi, Seung-Ho;Kim, Sang-Yoon;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.1
    • /
    • pp.49-52
    • /
    • 2006
  • Background and Objectives: Vocal cord granuloma is a exophytic inflammatory mass and caused by gastroesophageal reflux, voice abuse, endotracheal intubation. There has been a controversy in the treatment of vocal cord granuloma. Our aim of study is to know the clinical characteristics and the results of surgical management for vocal cord granuloma. Materials and Methods: We have reviewed and analyzed medical records of 55 patients who were diagnosed and surgically treated as vocal cord granuloma in Asan medical center from 1997 to 2005 retrospectively. Results: 25 cases were intubation granuloma and 30 cases were contact granuloma. In intubation granuloma, the clinical manifestation was hoarseness(70%), foreign body sensation(44%), chronic cough(21%). In contact granuloma, the clinical manifestation was hoarseness(67%), foreign body sensation(60%), throat clearing(21%). The recurrence rate after surgery was 8% in intubation granuloma and 33% in contact granuloma. Mean recurrence time was 4.1months in intubation granuloma and 3.2months in contact granuloma. Conclusion: Although there is no significant difference, recurrence rate after surgery was high in contact granuloma compared to intubation granuloma(p=0.125). Although this study is retrospective, surgical management must be considered in resolving diagnostic doubt, treating airway obstruction, and failure in conservative treatments.

  • PDF

The Graft Polymerization of Acrylic Acid in Vapour Phase onto Poly(ethylene terephthalate) by Cold Plasma Part (I) (저온 Plasma를 이용한 Poly(ethylene terephthalate)에의 Acrylic Acid의 기상 Graft 공중합 반응(I))

  • 천태일;최석철;모상영
    • Textile Coloration and Finishing
    • /
    • v.1 no.1
    • /
    • pp.7-18
    • /
    • 1989
  • The distinguishing characteristic of the glow discharge is that chemical reaction induced by partially ionized gases are limited only to the substrate surface. Most studies have been done on the plasma etching and polymerization. The graft polymerization in vapour phase by cold plasma has been rarely investigated. In this study the system of tub3ar reaction chamber with capacitively coupled electrode of alternative current of 60 Hz was employed for the graft polymerization. The graft polymerization of Acylic Acid(AA) onto the poly (ethylene terephthalate) (PET) was carried out by treatment of PET film and fabric by cold plasma (glow discharge of argon gas), followed by the supply of AA vapour. The graft yield was about 1 wt%. The surface property was determined by contact angle, the surface tension was evaluated by zisman’s plot and equation of surface tension mesurement. The results were as follows: 1. In order to obtain lower contact angle, it was effective to avoid the vicinity of electrodes for a setting position of substrate. 2. Contact angle affected on the monomer pressure and its duration of exposure to the acid vapour. 3. Polymer radical formation was influenced by the changes of the value of current density and plasma treatment time. 4. Total surface tension of plasma grafted PET film increased. With an increase in the carboxylic acid content, the dispersion force decreased, while, the polar force and hydrogen bonding force increased. 5. The contact angle decreased from $75^\circ$ to around $30^\circ$ by plasma grafting. There was no ageing effect on the contact angle after 4 months.

  • PDF

Industrial-scale biological treatment of Chinese nutgall processing wastewater by combined expanded granular sludge bed and bio-contact oxidation

  • Wu, Yundong;Zhou, Kanggen;Dong, Shuyu;Yu, Wei;Liang, Chunsheng
    • Environmental Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.336-341
    • /
    • 2015
  • The industrial-scale biological treatment of Chinese nutgall processing wastewater was conducted with a $200m^3$ expanded granular sludge bed reactor and a $900m^3$ bio-contact oxidation reactor. The temperature of the two reactors was controlled under mesophilic conditions ($32-40^{\circ}C$), through changing the proportion of the dilution water, which was composed of steam condensation water and residual circulating water. The effluent COD, gallic acid, chroma, total nitrogen, total phosphorus levels and pH of both the expanded granular sludge bed and bio-contact oxidation reactors were monitored. In addition, the redox potential in the expanded granular sludge bed was recorded. The total COD removal efficiency was 87.257% when the influent COD concentration was $14\;251{\pm}3\;148mg/L$, and the ratio of wastewater: dilution water was 1:5. The removal efficiencies of gallic acid, chroma, total nitrogen, and total phosphorus were 72.221%, 43.940%, 64.151% and 39.316%, respectively. The effluent pH increased in either the expanded granular sludge bed reactor or the bio-contact oxidation reactor during the operation. The redox potential in the expanded granular sludge bed varied between -367 mV and -435 mV. The results indicate that the combined process was suitable for treating Chinese nutgall processing wastewater.