• 제목/요약/키워드: Contact System

검색결과 3,930건 처리시간 0.033초

3차원 측정기용 비젼프로브 운용시스템 개발 (Development of Managing System of Vision Probe for CMM)

  • 박재성;박희재;김구영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.501-505
    • /
    • 1996
  • In CMM system, a contact probe is not applicable to very small, or flexible elements. There is need to develop non-contact probes of CCD camera. But non-contact probes have some technical problems, including distortion, user interface and time delay. This development gives the foundation of the non-contact probe system and some useful solutions for the problems. The results can be useful for industry application.

  • PDF

경사진 전극링에 의한 웨이퍼레벨패키지용 고균일도의 솔더범프 형성 (Formation of high uniformity solder bump for wafer level package by tilted electrode ring)

  • 주철원;이경호;민병규;김성일;이종민;강영일;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.366-369
    • /
    • 2003
  • The vertical fountain plating system with the point contact has been used in semiconductor industry. But the plating shape in the opening of photoresist becomes gradated shape, because bubbles from the wafer surface are difficult to escape from the deep openings, vias. So, we designed the tilted electrode ring contact to get uniform bump height on all over the wafer and evaluated the film uniformity by SEM and $\alpha$-step. A photoresist was coated to a thickness of $60{\mu}m$ and vias were patterned by a contact aligner After via opening, solder layer was electroplated using the fountain plating system and the tilted electrode ring contact system. In $\alpha$-step measurement, film uniformities in the fountain plating system and the tilted electrode ring contact system were ${\pm}16%,\;{\pm}3.7%$ respectively. In this study, we could get high uniformity bumps by the tilted electrode ring contact system. So, tilted electrode ring contact system is expected to improve workability and yield in module process.

  • PDF

Development of 460V/225A/50㎄ Contact System in Current Limiting Molded Case Circuit Breakers

  • Park, Young-Kil;Park, Chan-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권4호
    • /
    • pp.165-172
    • /
    • 2003
  • Low voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. This paper is focused on understanding the interrupting capability, more specifically of the contacts and the arc runner, based on the shape of the contact system in the current molded case circuit breaker (hereafter MCCB). Moreover, in order to improve the interrupting capability of the circuit breaker, the estimation and analysis of the interrupting capability, based on the 3-D magnetic flux analysis, were developed. Furthermore, this paper also presents results of the estimation and analysis of the interrupting capability when applied to different model breakers. In addition, this paper analyzes the efficiency of the interrupting tests by forming false current paths consisting of a three-division cascade arc runner in the contact system. With regards to the interrupting test, there is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by the current and flux density be present. Based on the results of this study, this paper presents both computational analysis and test results for the newly developed MCCB 460V/225A/50㎄ contact system.

철도 가선시스템의 감쇄 특성 파악에 관한 연구 (A study on identification of the damping ratio in a railway catenary system)

  • 박성용;전병욱;이응신;조용현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.529-533
    • /
    • 2005
  • A railway catenary system which supplies a train with electric power is an important system in determining the maximum speed of an electric train. However, a pantograph could be separated from a contact wire because of reciprocal action between a pantograph with constant upward force and a catenary system. The contact loss of a pantograph-catenary system is mainly affected by the dynamic characteristics of damping and wave propagation velocity of contact wire. For increasing speed of an electrical train, it is necessary to establish the techniques to identify the modal parameter of a catenary system through experiment. However, it is difficult to decouple each mode and to extract respect ive damping rat io since a catenary system has an extremely high modal density. For this reason, mode decoupling process to identify modal parameters is a principal technique in analyzing a catenary system. In this paper, the damping extract ion method for a catenary system using the continuous wavelet transform is discussed.

  • PDF

Analytical and finite element solution of a receding contact problem

  • Adiyaman, Gokhan;Yaylaci, Murat;Birinci, Ahmet
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.69-85
    • /
    • 2015
  • In this paper, a receding contact problem for an elastic layer resting on two quarter planes is considered. The layer is pressed by a stamp and distributed loads. It is assumed that the contact surfaces are frictionless and only compressive traction can be transmitted through the contact surfaces. In addition the effect of body forces are neglected. Firstly, the problem is solved analytically based on theory of elasticity. In this solution, the problem is reduced into a system of singular integral equations in which contact areas and contact stresses are unknowns using boundary conditions and integral transform techniques. This system is solved numerically using Gauss-Jacobi integral formulation. Secondly, two dimensional finite element analysis of the problem is carried out using ANSYS. The dimensionless quantities for the contact areas and the contact pressures are calculated under various distributed load conditions using both solutions. It is concluded that the position and the magnitude of the distributed load have an important role on the contact area and contact pressure distribution between layer and quarter plane contact surface. The analytic results are verified by comparison with finite element results.

비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성 (Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor)

  • 전화봉;윤정원;김성홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo, Sung-Il;Cho, Yong-Hyun;Mok, Jin-Yong;Park, Choon-Soo;Kim, Ki-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1374-1378
    • /
    • 2005
  • Appropriate upward force is crucial for the pantograph on high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the arms of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measurement system was developed. The forces acting on the pantograph were clarified and a procedure to calculate the aerodynamic lifting force was proposed. A special device was invented and applied to measure the lifting force. Measured contact forces were displayed by the developed system and evaluated according to the criteria. Countermeasures were also taken to reduce the contact force based on the results.

  • PDF

슬라이딩 접촉에 의한 집전시스템의 성능향상의 연구 (A study on the performance increasing of current collecting system with a sliding contact)

  • 정락교;김연수;윤용기;박성혁;정상기;이병송;목진용;최성규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 1999
  • In this paper, the wearing characteristics of current collecting shoes, interruption phenomena and contact resistances between collecting shoes and conductor rails are established as design parameters for development of the third rail current collector. An experimental analysis for established design parameters is performed as the materials of current collector shoe, contact force, sliding velocity and contact condition(dry/wet condition) between current collectors shoe and conductor rails. As a result of this study, the magnitude of contact force is in proportion to the amount of wear in the collecting shoe, but is in inverse proportion to the interruption and contact resistance between the collecting shoe and the conductor rail. And optimal values of design parameters are pre sented through analyzing the experimental results of the amount of wear, interruption and contact resistance.

  • PDF

Contact problem for a stringer plate weakened by a periodic system of variable width slots

  • Mir-Salim-zada, Minavar V.
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.719-724
    • /
    • 2017
  • We consider an elastic isotropic plate reinforced by stringers and weakened by a periodic system of rectilinear slots of variable width. The variable width of the slots is comparable with elastic deformations. We study the case when the slots faces get in contact at some area. Determination of parameters characterizing the partial closure of variable width slots is reduced to the solution of a singular integral equation. The action of the stringers is replaced with unknown equivalent concentrated forces at the points of their connection with the plate. The contact stresses and contact zone sizes are found from the solution of the singular integral equation.

각접촉 볼 베어링의 정위치 예압 변화에 따른 회전체 계 동특성 변화 연구 (A Study on the dynamic characteristics of rotor systems supported by angular contact ball bearings with the axial displacement preload varied)

  • 강중옥;홍성욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.389-392
    • /
    • 1997
  • This paper presents the dynamic analysis and experiment for rotor systems supported by angular contact ball bearings subjected to axial displacement preload. A dynamic software, which has been developed by the authors for the analysis of rotor systems supported by angular contact ball bearings, is used to simulate a uniform shaft system supported by two angular contact ball bearings with the axial displacement preload varied. Experiments are also performed to validate the simulation. An experimental system is constructed which consists of a uniform shaft, two bearings and a device for adjusting the axial displacement preload. Through a series of simulation and experiment, the dynamic characteristics of rotor systems with angular contact ball bearings subject to axial displacement preload are investigated.

  • PDF