• Title/Summary/Keyword: Contact Stability

Search Result 747, Processing Time 0.028 seconds

The relationship between initial implant stability quotient values and bone -to-implant contact ratio in the rabbit tibia

  • Park, In-Phill;Kim, Seong-Kyun;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.76-80
    • /
    • 2011
  • PURPOSE. Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS. Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS. Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION. In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.

The Effect of Circle Contact Lens on the Stability of Tear Film (써클콘택트렌즈가 눈물막 안정성에 미치는 영향)

  • Lee, Sehee;Hyung, Sung Min;Koh, Seung Hwan;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • Purpose: The effect of pigmentation in circle contact lens on lens wearers' tear film stability was investigated in this study. Methods: Non-invasive tear film break-up times of 54 normal eyes before and after lens wearing in twenties and the portion of first tear breakup were measured. The frontal and back surface roughness of circle contact lens was further observed with a scanning electron microscope. The clear lens which was made of hilafilcon B and circle contact lenses which were made of hilafilcon B, polymacon and copolymer of HEMA NVP were tested. Results: Non-invasive tear film breakup time was significantly reduced compared with it before lens wearing. In some case, statistically significant difference in tear film breakup time was also observed between circle contact lenses. The tear file break-up was usually early started in lower than upper portion, and in temporal than nasal portion although there was variation in the lens material. The tear film break-up of circle contact lenses made of hilafilcon B was more commonly observed in peripheral portion(pigmented area) compared with clear contact lens made of same material. Conclusions: The present study revealed that the stability of tear film was affected by wearing circle contact lens and the result seems to be used as the basis for the problem solving that can occur due to the pigmentation when wearing circle contact lens.

Electrical Characteristics of $TiSi_2$ Salicide Contact ($TiSi_2$ SALICIDE CONTACT의 전기적 특성)

  • Lee, Cheol-Jin;Yang, Ji-Woon;Lee, Nae-In;Sung, Yung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.178-182
    • /
    • 1991
  • Contact resistance and contact leakage current of the $Al/TiSi_2/Si$ system are investigated for $N^+\;and\;P^+$ junctions. Titanium disilicide is one of the most common silicides because of its thermal stability, ability, to form selective formation and low resistivity. In this paper, the effect of RTA temperature and Junction implant dose are characterized. The $TiSi_2$ contact resistance to $N^+$ silicon is lower than that of Al to $N^+$ silicon, but $TiSi_2$ of contact resistance to $P^+$ silicon is higher than that of Al to $P^+$ silicon. The $TiSi_2$ of contact leakage current to $N^+\;and\;P^+$ silicon is similar to that of Al contact.

  • PDF

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF

Studies on the Surface Properties of PMMA after Accelerated Weathering

  • Kwon, Young Bum;Ha, Jin Uk;Hwang, Ye Jin;Oh, Jeong Seok
    • Elastomers and Composites
    • /
    • v.51 no.4
    • /
    • pp.350-354
    • /
    • 2016
  • The surface properties of poly(methyl methacrylate) (PMMA) were investigated after accelerated weathering. Glossinesses, contact angles, surface free energies, thermal stability, and mechanical properties were investigated. The glossiness of the weathered PMMA was decreased with increasing exposure time. Contact angles and surface free energies were not overtly changed because the amount of oxygen on the surface was remained. PMMA was compounded with anti-block and antistatic agents using a co-rotating twin screw extruder to improve the durability. The PMMA composites showed better glossinesses after accelerated weathering while maintaining the contact angles, surface energy, thermal stability, and mechanical properties without significant changes.

Analysis of Contact and Separation between the Catenary and the Pantograph of a High-speed Electrical Train Considering the Dropper Positions (드롭퍼 위치를 고려한 고속전철 전력선과 급전기의 접촉 분리 해석)

  • Lee, Ki-Su
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.427-436
    • /
    • 2007
  • The catenary of a high-speed electrical train is modeled by the finite elements with the upper suspension wire, lower contact wire, and droppers, and the dynamic contact between the catenary and the pantograph is numerically analyzed by solving the whole equations of motion of the pantograph and the catenary system subjected to the contact condition. For the stability of the numerical solution, with the cubic spline interpolation of the catenary displacement, the velocity and acceleration constraints as well as the displacement constraint are imposed on the contact point. Through the various numerical examples, it is shown that the dropper positions as well as the static deflection are crucial to determine the contact and separation of the pantograph of a high-speed train.

Determination of Optimal Contact Forces for Multi-Jointed, Multi-Fingered Robotic Hand Considering Contacts of Inner Links (손마디 접촉을 고려한 다지 다관절 로봇손의 최적 접촉력 결정 방법)

  • 백주현;정낙영;서일홍;최동훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.8
    • /
    • pp.825-835
    • /
    • 1991
  • This paper deals with a case for robotic hands to grasp the objects using inner link contact as well as fingertip contact. And the case is proved to be more efficient than the case of using only fingertip contact in terms of stability and uniform distribution of the contact forces. The general algorithm for the determination of the optimal ocntact force is developed for the soft finger contact as well as the point contact with friction. To show the validity of the proposed algorithm a numerical example is illustated by employing a robotic hand with three fingers each of which has four joints.

A STUDY ON BONE-CONTACT TO INTER-SEGMENTAL LENGTH RATIO OF RIGID FIXATION SCREWS USED IN BSSRO FOR MANDIBULAR SETBACK (하악지 시상절단술시 견고 고정 나사의 골편간/골내 길이 및 비율에 대한 연구)

  • Cho, Sung-Min;Kim, Seong-Hun;Park, Je-Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.329-334
    • /
    • 2009
  • Objective: To evaluate the ratio between bone-contact length and inter-segmental length of the rigid fixation screw used in bilateral sagittal split ramus osteotomy (BSSRO) for mandibular setback. Material and Methods: Records of 40 patients with Class III malocclusion were selected. 20 of them had BSSRO, while the other 20 had BSSRO with maxillary LeFort I osteotomy. All of the patients had three noncompressive bicortical screws inserted at the gonial angle through transcutaneous approach. Two screws were inserted antero-posteriorly above inferior alveolar nerve and one screw was inserted below. The lengths of bone-contact and that of inter-segmental part were measured using cone-beam computed tomography. Ratio between these two measured lengths was calculated. Results: Both bone-contact and inter-segmental lengths were longer in BSSRO group than in BSSRO with maxillary LeFort I osteotomy group. Ratio of bone-contact to inter-segmental length was lower in BSSRO group than in BSSRO with Lefort I group. Both bone-contact and inter-segmental lengths were longer at the antero-superior position than at the inferior position. However, their ratio showed little difference. Conclusion: This study suggest that stability of screws in BSSRO group was greater than in BSSRO with Lefort I group. Stability of screws at the antero-superior position was greater than at the inferior position. Ratio of bone-contact to inter-segmental lengths was 0.2 in average.

Dimensional Change of Acetylated Hardwood (아세틸화 활엽수재의 치수변화 특성)

  • 한규성
    • Journal of the Korea Furniture Society
    • /
    • v.11 no.2
    • /
    • pp.79-84
    • /
    • 2000
  • It is well-known fact that dimensional stability of wood is greatly enhanced by acetylation of wood. This dimensional stability results from bulking of the reacted acetate within the cell wall, which reduces further swelling when the modified woods come into contact with water or water vapor. The purpose of this research was to determine the water absorption and dimensional stability of the acetylated solid wood in liquid water and in humidity tests. Beech and red oak were acetylated. Moisture and water absorption of acetylated wood were quite dependent on weight percent gain(WPG). Antiswelling efficiency(ASE) was quite dependent on WPG, but was not dependent on species.

  • PDF

Stability of Co/Ni Silicide in Metal Contact Dry Etch (Co/Ni 복합실리사이드의 메탈 콘택 건식식각 안정성 연구)

  • Song Ohsung;Beom Sungjin;Kim Dugjoong
    • Korean Journal of Materials Research
    • /
    • v.14 no.8
    • /
    • pp.573-578
    • /
    • 2004
  • Newly developed silicide materials for ULSI should have the appropriate electrical property of low resistant as well as process compatibility in conventional CMOS process. We prepared $NiCoSi_x$ silicides from 15 nm-Co/15 nm-Ni/Si structure and performed contact dry etch process to confirm the dry etch stability and compatibility of $NiCoSi_x$ layers. We dry etched the photoresist/SiO/silicide/silicon patterns with $CF_4\;and\;CHF_3$ gases with varying powers from 100 to 200 W, and pressures from 45 to 65 mTorr, respectively. Polysilicon and silicon active layers without silicide were etched $0\sim316{\AA}$ during over etch time of 3min, while silicon layers with proposed $NiCoSi_x$ silicide were not etched and showed stable surfaces. Our result implies that new $NiCoSi_x$ silicides may replace the conventional silicides due to contact etch process compatibility.