• Title/Summary/Keyword: Contact Region

Search Result 672, Processing Time 0.03 seconds

Application of DC Resistivity Survey from Upper Portion of Concrete and Geostatistical Integrated Analysis (콘크리트 상부에서 전기비저항 탐사 적용 및 지구통계학적 복합 해석)

  • Lee, Heuisoon;Oh, Seokhoon;Chung, Hojoon;Noh, Myounggun;Ji, Yoonsoo;Ahn, Taegyu;Song, Sung-Ho;Yong, Hwan-Ho
    • Journal of the Korean earth science society
    • /
    • v.35 no.1
    • /
    • pp.29-40
    • /
    • 2014
  • A DC resistivity survey was performed to detect anomalies beneath concrete pavement. A set of high conductive media and planar electrodes were used to lessen the effect's a high contact resistance of concrete. Results of the resistivity survey were analyzed and compared with those of other geophysical surveys such as Ground Penetration Radar (GPR), Impulse Response (IR), and Multi-channel Analysis of Surface Waves (MASW), which were carried out in the same location. The results of resistivity survey showed a high resistive distribution in the section of sink and pavement where a pattern of reinforcement was observed through the GPR survey. Also, a comparison of results between the IR and resistivity surveys indicated that the high resistivity was produced by the high dynamic stiffness in the reinforced section. The co-Kriging of both the results of DC resistivity and MASW surveys at the same location showed that an integrated geostatistical analysis is able to give more accurate description on the anomalous subsurface region than can a separate analysis of each geophysical approach. This study suggests that the integrated geostatistical approaches were used for a decision-making process based on the geophysical surveys.

A Report for the Quaternary Gaegok 6 Fault Developed in the Mid-eastern Part of Ulsan Fault Zone, Korea (울산단층대 중동부에 발달하는 제4기 개곡 6단층에 대한 보고)

  • Ryoo, Chung-Ryul
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.635-643
    • /
    • 2009
  • In this paper, a Quaternary fault is described, which is developed in the mid-eastern part of Ulsan Fault Zone, near the southern Gaegok-ri, Oedong-eub, Gyeongju, Korea. The Gaegok 6 fault is developed along the contact between Early Tertiary granite and Quaternary gravel deposit overlying unconformably the granite. The fault strikes $N02^{\circ}{\sim}22^{\circ}E$ and dips $45^{\circ}{\sim}80^{\circ}$ to the west. This fault has a 30~50 cm wide cataclastic shear zone with gouge zone, mixed with Quaternary sediments and fault breccia of granite. In the main Quaternary fault plane, the orientation of striation is $17^{\circ}$, $356^{\circ}$, indicating a dextral strike-slip faulting with some normal component. There is another striation ($78^{\circ}$, $278^{\circ}$ and $43^{\circ}$, $270^{\circ}$) with reverse-slip sense, developed on the subsidiary plane which cuts the main Quaternary fault plane. In brief, the fault has been developed between the granite in the western part and the Quaternary gravel deposit in the eastern part. The western block of fault is uplifted. The striations and movement senses of faults indicate multiple compressional stages in this region. The fault has a similar orientation, westward dipping geometric pattern, and reverse sensed kinematic pattern with Gaegok 1 fault developed in the north. Thus, the Gaegok 6 fault is probably a southern extension of Gaegok 1 fault.

The Effects of functional foot orthotics on the balance according to Foot Shape (기능성 발보조기의 족부형태별 균형유지에 미치는 영향)

  • Chai, S.W.;Park, K.Y.;Kim, Y.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • The functional loot orthoses, when wearing shoes, are in the direct contact with bottom of foots to improve and recover the correctness of abnormal lower limb musculoskeletal imbalance and the primary role of foot and also, it can act to keep the balance and weight of body and support the weakened region, so that it is very helpful to keep body balance for the standing position. In this paper, it was researched that foot orthoses which is accommodable for the function of impact absorption including the gait stability affect on the balanced performances of body in according to the formation and the material of foot part. Taking into account the balanced performances by using the sway velocity, the estimation and comparison of the effects on the balanced performances by each formation and material for foot orthoses was evaluated into significant values(p<0.006) in only the eye-opening posture with Firm state, In this posture, the static process performed by each foot formation reveals in order of normal foot(p<0.010), flat foot(p<0.000) and hollow foot(p<0.003) and then, on the base of each formation of foot part, the result that analyze the effects of the materials of foot orthoses on the balance performance appeared showing that soft materials is more effective on the normal foot and, on the other hand, rigid materials is more effective in balancing on flat foot and hollow foot.

Design of Vision Based Punching Machine having Serial Communication

  • Lee, Young-Choon;Lee, Seong-Cheol;Kim, Seong-Min
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2430-2434
    • /
    • 2005
  • Automatic FPC punching instrument for the improvement of working condition and cost saving is introduced in this paper. FPC(flexible printed circuit) is used to detect the contact position of K/B and button like a cellular phone. Depending on the quality of the printed ink and position of reference punching point to the FPC, the resistance and current are varied to the malfunctioning values. The size of reference punching point is 2mm and the above. Because the punching operation is done manually, the accuracy of the punching degree is varied with operator's condition. Recently, The punching accuracy has deteriorated severely to the 2mm punching reference hall so that assembly of the K/B has hardly done. To improve this manual punching operation to the FPC, automatic FPC punching system is introduced. Precise mechanical parts like a 5-step stepping motor and ball screw mechanism are designed and tested and low cost PC camera is used for the sake of cost down instead of using high quality vision systems for the FA. 3D Mechanical design tool(Pro/E) is used to manage the exact tolerance circumstances and avoid design failures. Simulation is performed to make the complete vision based punching machine before assembly, and this procedure led to the manufacturing cost saving. As the image processing algorithms, dilation, erosion, and threshold calculation is applied to obtain an exact center position from the FPC print marks. These image processing algorithms made the original images having various noises have clean binary pixels which is easy to calculate the center position of print marks. Moment and Least square method are used to calculate the center position of objects. In this development circumstance, Moment method was superior to the Least square one at the calculation of speed and against noise. Main control panel is programmed by Visual C++ and graphical Active X for the whole management of vision based automatic punching machine. Operating modes like manual, calibration, and automatic mode are added to the main control panel for the compensation of bad FPC print conditions and mechanical tolerance occurring in the case of punch and die reassembly. Test algorithms and programs showed good results to the designed automatic punching system and led to the increase of productivity and huge cost down to law material like FPC by avoiding bad quality.

  • PDF

Use of Mouthguard for Prevention of Oral and Maxillofacial Injury (구강악안면영역의 외상방지를 위한 마우스가드의 사용)

  • Shim, Young-Joo;Kang, Jin-Kyu
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.251-256
    • /
    • 2012
  • With today's heightened interest in quality of life, leisure and sports activities were popular in the general public. Accordingly, the incidence of oral and maxillofacial injury are also rising. Use of a mouth protector to prevent the trauma of the oral and maxillofacial region is growing in importance, and among the mouth protector the mouthguard is the most commonly used. Mouthguard has been suggested to protect injuries by (1) preventing tooth injuries by absorbing and deflecting blows to the teeth; (2) shielding the lips, tongue, and gingival tissues from laceration; (3) preventing opposing teeth from coming into violent contact; (4) providing the mandible with resilient support, which absorbs an impact that might fracture the unsupported angle or condyle of the mandible; (5) preventing neck and cerebral brain injuries. Although mouthguard is effective for prevention of oral and maxillofacial injury, it is not widespread to athletes or general public and they are lack of awareness about the importance of mouthguard. We present the types and materials of mouthguard, things to consider when mouthguard fabrication, and the usage. This should be helpful in awareness about the importance and popularization of mouthguard.

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

Comparative study of two CAD software programs on consistency between custom abutment design and the output (두 가지 CAD software의 맞춤형 지대주 디자인과 출력물 일치도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Son, KeunBaDa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.157-166
    • /
    • 2018
  • Purpose: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. Materials and Methods: Customized abutments were designed by using 3Shape Dental System CAD software and Delta9 CAD software on a plaster model with implants (CRM STL file). After milling of the designed abutments, the abutments were scanned with a contact method scanner (Test STL file). We overlaid the Test STL file with each CRM STL file by using inspection software, and then compared the milling reproducibility by measuring the output error of the specimens from each CAD software program. Results: The Delta9 showed better milling reproducibility than 3Shape when comparing the milling errors obtained with a full scan of all specimens (P < .05) and also when comparing the axial wall region specifically according to the axial angle. With 0.9 mm marginal radius, the Delta9 showed better consistency between the design and the output than 3Shape (P < .05). While, anti-rotation form had no significant difference in error between the two systems. When cumulative errors were compared, the Delta9 showed better milling reproducibility in almost cases (P < .05). Conclusion: Delta9 showed a significantly smaller error for most of the abutment design options. This means that it is possible to facilitate generation of printouts with reliable reproducibility and high precision with respect to the planned design.

The Incidence and Patterns of Unintentional Injuries in Daily Life in Korea: A Nationwide Study (우리나라 생활안전영역의 비의도적 손상 발생률 및 발생 양상)

  • Park, Kun-Hee;Eun, Sang-Jun;Lee, Eun-Jung;Lee, Chae-Eun;Park, Doo-Yong;Han, Kyoung-Hun;Kim, Yoon;Lee, Jin-Seok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.41 no.4
    • /
    • pp.265-271
    • /
    • 2008
  • Objectives: This study was conducted to estimate the cumulative incidence rate (CIR) of unintentional injuries in Korean daily life and to describe the pattern of unintentional injuries. Methods: The study population was the people who used the National Health Insurance because of injuries (ICD code: S00$\sim$T98) during 2006. The stratified sample according to gender, age and the severity of injury (NISS, New Injury Severity Score) was randomly selected. The questions on the questionnaire were developed as a reference for an international classification tool (ICECI, International Classification of External Causes of Injury). The questions included the locations of injury, the mechanisms of injury and the results of injury. Moreover, we used age, gender, region and income variables for analysis. Results: The CIR of unintentional injuries that occurred in daily life for 1 year per 100,000 persons was 17,606, and the CIR of severe injuries was 286. Many injuries were occurred at home (29.6%), public places (19.0%), school (13.7%) and near home (12.0%). The major mechanisms of injuries were slipping (48.8%), contact (14.0%), physical over-exertion (13.8%), and fall (6.6%). Infants and old aged people were vulnerable to injuries, and those who lived rural area and who were in a low income level were vulnerable too. Conclusions: We signified the risk groups and risk settings of unintentional injuries in Korean daily life. These results could contribute to establishing strategies for injury prevention and implementing these strategies.

Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater (Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징)

  • 심영대;신규호;좌성훈;김용준
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • In this project, the efficiency of localized heating for micro systems packaging is developed by using a forced potential scheme microheater. Less than 0.2 Mpa contact pressure was used for bonding with a 200 mA current input for $50{\mu}m$ width, $2{\mu}m$ height and $8mm{\times}8mm$, $5mm{\times}5mm$, $3mm{\times}3mm$ sized phosphorus-doped poly-silicon microheater. The temperature can be raised at the bonding region to $800^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3 minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional microheaters. For performing the gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for conducting a gross leak check. The pass ratio of bonded dies was 67%, for conventional localized heating, and 85% for our newly developed FP scheme. The bonding strength was more than 25Mpa for FP scheme packaging, which shows that FP scheme can be a good candidate for micro-scale hermetic packaging.

  • PDF

The introduction of a criminal case arbitration on premise the civil and commercial arbitration (민상사(民商事) 중재제도(仲裁制度)를 전제(前提)로 한 형사중재제도(刑事仲裁制度)의 도입방안(導入方案))

  • Nam, Seon-Mo
    • Journal of Arbitration Studies
    • /
    • v.19 no.3
    • /
    • pp.93-119
    • /
    • 2009
  • Nowadays the number of crimes is increasing rapidly and society is getting more and more dangerous. Recently the criminal aspect of our society, the intelligence, diversity, localized area, as well as for the crime victims also difficult to predict the damage recovery is not easy to change their level of pain and are also serious. This phenomenon is increasingly expected to intensify, the proper response is a factory. The more so if the victim of murder. The criminal mediation working on the operational adjustments Borrower payment, Construction charges, investments and financial transactions due to interpersonal conflicts that occurred as a fraud, embezzlement, breach of trust property crimes such accused, individuals between the defamatory, offensive, encroachment, violating intellectual property rights and private Disputes about the complaint case and other criminal disputes submitted to mediation to resolve it deems relevant to the case who are accused. But the core of a detective control adjustment, adjust the members' representative to the region, including front-line player or a lawyer appointed by the attorney general at this time by becoming parties to this negative view may be ahead. Some scholars are criticizing the current criminal justice system for the absence of proper care for the criminal victims, as an alternative to the traditional criminal justice system. The introduction of the summary trial and related legal cases, the command structure, compensation system, crime victims' structural system can be seen as more classify, crime subject to victim's complaint, By case with a criminal misdemeanor in addition to disagree not punish criminal, minor offense destination, traffic offenders, regular property crime, credit card theft, intellectual property rights violators can be seen due to more categories can try. They sued in law enforcement, Prosecution case has been received and if any one party to the criminal detective Arbitration request arbitration by the parties can agree to immediately contact must be referred to arbitration within 15 days of when the arbitration case will be dismissed. These kinds of early results of the case related to, lawyers are involved directly in the arbitration shall be excluded. Arbitration system is the introduction of criminal justice agencies working to help resolve conflicts caused by adjustment problems will be able to. This article does not argue that we should stick to the traditional justice system as a whole. Instead it argues that the restrictive role of the traditional justice is to be preserved.

  • PDF