• Title/Summary/Keyword: Contact Region

Search Result 669, Processing Time 0.029 seconds

Design and Fabrication of a Si pin Photodetector with Peak Spectral Response in the Red Light for Optical Link (적색 중심 Optical Link용 Si pin Photodetector의 설계 및 제작)

  • 장지근;김윤희;이지현;강현구;이상열
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • We have fabricated and evaluated a new Si pin photodetector for APF optical link. The fabricated device has the $p^{+}$-guard ring around the metal-semiconductor contact and the web patterned $p^{+}$-shallow diffused region in the light absorbing area. From the measurements of electo-optical characteristics under the bias of -5 V, the junction capacitance of 4 pF and the dark current of 180 pA were obtained. The optical signal current of 1.22 $\mu$A and the responsivity of 0.55 A/W were obtained when the 2.2 $\mu$W optical power with peak wavelength of 670 nm was incident on the device. The fabricated device showed the maximum spectral response in a spectrum of 650-700 nm. It is expected that the fabricated device can be very useful for detecting the optical signal in the application of red light optics.

  • PDF

Fabrication and Characteristics of Photoconductive Amorphous Silicon Film for Facsimile (팩시밀리용 비정질 실리콘 광도전막의 제작 및 특성)

  • Kim, Jeong-Seob;Oh, Sang-Kwang;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • Contact-type linear image sensors for facsimile have been fabricated by means of rf glow discharge decomposition method of silane. The dependence of their electrical and optical properties on rf power, $SiH_4$ flow rate, ambient gas pressure, $H_2SiH_4$ ratio and substrate temperature are described. The a-Si:H monolayer demonstriated photosensitivity of 0.85 and $I_{ph}/I_d$ ratio of 100 unger 100 lux illumination. However, this monolayer has relatively high dark current due to carrier injection from both electrodes, resulting in low $I_{ph}/I_{dd}$ ratio. To suppress the dark current we have fabricated $SiO_2/i-a-Si:H/p-a-Si:H:B$ multilayer film with blocking structure. The photocurrent of this multilayer sensor with 6 V bias became saturated ar about 20nA under 10 lux illumination, while the dark current was less than 0.2 nA. Moreover, the spectral sensitivity of the multilayer film was enhanced for short wavelength visible region, compared with that of the a-Si:H monolayer. These results show that the fabricated photocon-ductive film can be used as the linear image sensor of the facsimile.

  • PDF

Aplastic anemia and dental implant rehabilitation: a clinical trial

  • Kim, Jun-Hwa;Shet, Uttom Kumar;Kim, Byeong-Guk;Kim, Myung-In;Kook, Min-Suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju;Jung, Seunggon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.265-269
    • /
    • 2015
  • The purpose of this study was to investigate implant-supported restoration as a technique for restoring missing teeth in patients with aplastic anemia. Recurrent bleeding from wound sites leads to persistent release of iron in the tissue. Excessive iron in tissue is related to clinical findings, including fibrosis, poor wound healing, and high level of angiogenesis, which are possible etiological factors of reduced osseointegration. A 44-year-old female patient with aplastic anemia was treated with multiple endosseous implants throughout the mandible and in the posterior region of the maxilla. After 14 implants were placed, radiological and clinical parameters were assessed during the follow-up period. Marginal bone did not change significantly during the follow-up period. The fine trabecular bone in intimate contact and enclosing the implant fixture was sufficient for successful osseointegration. None of the 14 implants were associated with compilations during the seven-year experimental period. This study suggests that dental implant procedures are a safe and reliable treatment option for restoration of missing dentition in patients with aplastic anemia.

A finite element stress analysis on the supporting bone and abutment screw by tightening torque of dental implant abutment screw (치과용 임플란트 지대주나사의 조임체결력에 따른 지지골과 지대주나사의 유한요소법 응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.99-105
    • /
    • 2020
  • Purpose: A study analysed the stress distribution of abutment screw and supporting bone of fixture by the tightening torque force of the abutment screw within clinical treatment situation for the stability of the dental implant prosthesis. Methods: The finite element analysis was targeted to the mandibular molar crown model, and the implant was internal type 4.0 mm diameter, 10.0 mm length fixture and abutment screw and supporting bone. The occlusal surface was modeled in 4 cusps and loaded 100 N to the buccal cusps. The connection between the abutment and the fixture was achieved by combining three abutment tightening torque forces of 20, 25, and 30 Ncm. Results: The results showed that the maximum stress value of the supporting bone was found in the buccal cortical bone region of the fixture in all models. The von Mises stress value of each model showed 184.5 MPa at the 20 Ncm model, 195.3 MPa in the 25 Ncm model, and 216.5 MPa in the 30 Ncm model. The contact stress between the abutment and the abutment screw showed the stress value in the 20 Ncm model was 201.2 MPa, and the 245.5 MPa in the 25 Ncm model and 314.0 MPa in the 30 Ncm model. Conclusion: The increase of tightening force within the clinical range of the abutment screw of the implant dental prosthesis was found to have no problem with the stability of the supporting bone and the abutment screw.

Isothermal Characteristics of a Rectangular Parallelepiped Sodium Heat Pipe

  • Boo Joon Hong;Park Soo Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1044-1051
    • /
    • 2005
  • The isothermal characteristics of a rectangular parallelepiped sodium heat pipe were inves­tigated for high-temperature applications. The heat pipes was made of stainless steel of which the dimension was $140\;m\;(L)\;{\times}\;95m\;(W)\;{\times}\;46 m\;(H)$ and the thickness of the container was 5 mm. Both inner surfaces of evaporator and condenser were covered with screen meshes to help spread the liquid state working fluid. To provide additional path for the working fluid, a lattice structure covered with screen mesh wick was inserted in the heat pipe. The bottom surface of the heat pipe was heated by an electric heater and the top surface was cooled by circulating coolant. The concern in this study was to enhance the temperature uniformity at the bottom surface of the heat pipe while an uneven heat source up to 900 W was in contact. The temperature distribution over the bottom surface was monitored at more than twenty six locations. It was found that the operating performance of the sodium heat pipe was critically affected by the inner wall temperature of the condenser region where the working fluid may be changed to a solid phase unless the temperature was higher than its melting point. The maximum temperature difference across the bottom surface was observed to be $114^{\circ}C$ for 850 W thermal load and $100^{\circ}C$ coolant inlet temperature. The effects of fill charge ratio, coolant inlet temperature and operating temperature on thermal performance of heat pipe were analyzed and discussed.

Current Status and Future Perspective of Nuclear Cardiology (심장핵의학의 현황과 전망)

  • Chung, June-Key
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.159-164
    • /
    • 2009
  • Coronary artery disease is on the rise over the world. Myocardial perfusion SPECT is a well established technique to detect coronary artery disease and to assess left ventricular function. In addition, it has the unique ability to predict the prognosis of the patients. Moreover, the application of ECC-gated images provided the quantitatve data and improved the accuracy. This approach has been proved to be cost-effective and suitable for the emerging economies as well as developed countries. However, the utilization of nuclear cardiology procedures vary widely considering the different countries and region of the world. Korea exits 2-3 times less utilization than Japan, and 20 times than the United States. Recently, with the emerging of new technology, namely cardiac CT, cardiac MR and stress echocardiography, the clinical usefulness of nuclear cardiology has been called in question and its role has been redefined. For the proper promotion of nuclear cardiology, special educations should be conducted since the nuclear cardiology has the contact points between nuclear medicine and cardiology. Several innovations are in horizon which will impact the diagnostic accuracy as well as imaging time and cost savings. Development of new tracers, gamma camera technology and hybrid systems will open the new avenue in cardiac imaging. The future of nuclear cardiology based on molecular imaging is very exciting. The newly defined biologic targets involving atherosclerosis and vascular vulnerability will allow the answers for the key clinical questions. Hybrid techniques including SPECT/CT indicate the direction in which clinical nuclear cardiology may be headed in the immediate future. To what extent nuclear cardiology will be passively absorbed by other modalities, or will actively incorporate other modalities, is up to the present and next generation of nuclear cardiologists.

A Comparative Study on the Relation between the Scholastic Achievement Test and the Intelligence according to the Area - Centering around the Scholastic Achievement Test of University - (지역간(地域間) 학력고사(學力考査)와 지능(知能)에 대(對)한 비교연구(比較硏究) -대학학력고사(大學學力考査)를 중심(中心)으로-)

  • Ryu Hui-Yeong;Kim Jeong-Hwa
    • Journal of Oriental Neuropsychiatry
    • /
    • v.1 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • On the Scholastic Achievement Test grads it was compared Chung Nam's with Cheon Puk by dividing a city, a farm village, a fishing village and a mountine village. The results were as follows ; 1. The regional difference of arerage grades were that the first is a large city, the second amiddle city, the third a mountine villgae, the fourth a fishing village, the last a farm village all the same Chung Nam and Cheon Puk. 2. The grades of acity and a farm of Chung Nam are higher then these of Cheon Puk. 3. Cheon Puk is higher than Chung Nam on a middle city, a mountine and a fishing's grades. 4. The characteristic was that the region of non benefits of civilization effect obstruction of intelligence less than a city mountine village. 5. It is considered that the obstruction of intelligence may diminish when eating marine products at a fishing village than a city-fishing village by side dish. From the above results, acknowledging a regional charater, it is suggested that improrement of food life imitate city shund sublate lest the physiological function of Bie Wee(脾胃) should converse a puthological state, get out of the food life civilization misled abnormal food life to normal. Systemic study must continue for maintaining of tradition of regional difference food life. By that manner excellent food life civilization may creat. Therefore it is recognized that experience accumulation of Oriental Medicine theory also close contact food life, so may make constent effort.

  • PDF

Comparison of Rectal and Infrared Thermometry for Obtaining Body Temperature of Gnotobiotic Piglets in Conventional Portable Germ Free Facility

  • Chung, Tae-Ho;Jung, Woo-Sung;Nam, Eui-Hwa;Kim, Ji-Hyun;Park, Seol-Hee;Hwang, Cheol-Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.10
    • /
    • pp.1364-1368
    • /
    • 2010
  • Gnotobiotic piglets (n = 10) were hand-reared in conventional germ-free facilities. Piglet body temperatures were measured with rectal and non-contact infrared thermometry (NIFT) on the lower eyelid, auricular center and margin, parietal regions, axilla, central abdomen and dorsum, and the perianal region. Body temperature measurements at central abdomen, cranial dorsum, and perianal regions had NIFT values which had a significant linear relationship (p<0.0001) with rectal thermometry. The predicted equations of between-subject formulas were calculated as follows: rectal temperature, 28.07489+0.30372${\times}$central abdominal surface temperature; rectal temperature, 34.02799+0.15197${\times}$central dorsum surface temperature; and rectal temperature, 33.87937+0.15676${\times}$perianal temperature. These results suggested that NIFT could serve as a valid alternative to rectal thermometry in a portable germ-free facility without disturbing experimental animals. The development of a NIFT body temperature evaluation that does not require animal restraint is clinically advantageous, particularly in gnotobiotic piglets, and would be significantly less stressful for experimental procedures in germ-free facilities.

Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam (Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석)

  • Kim, Douk-Hoon;Bae, Han-Yong
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

Skin Color Based Hand and Finger Detection for Gesture Recognition in CCTV Surveillance (CCTV 관제에서 동작 인식을 위한 색상 기반 손과 손가락 탐지)

  • Kang, Sung-Kwan;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.1-10
    • /
    • 2011
  • In this paper, we proposed the skin color based hand and finger detection technology for the gesture recognition in CCTV surveillance. The aim of this paper is to present the methodology for hand detection and propose the finger detection method. The detected hand and finger can be used to implement the non-contact mouse. This technology can be used to control the home devices such as home-theater and television. Skin color is used to segment the hand region from background and contour is extracted from the segmented hand. Analysis of contour gives us the location of finger tip in the hand. After detecting the location of the fingertip, this system tracks the fingertip by using only R channel alone, and in recognition of hand motions to apply differential image, such as the removal of useless image shows a robust side. We explain about experiment which relates in fingertip tracking and finger gestures recognition, and experiment result shows the accuracy above 96%.