References
- Alkan I, Sertgoz A, Bulent E. Influence of occlusal forces on stress distribution in preload dental implant screws. J Prosthet Dent, 91(4), 319-325, 2004. https://doi.org/10.1016/j.prosdent.2004.01.016
- Guda T, Ross TA, Lang LA, Millwater HR. Probabilistic analysis of preload in the abutment screw of a dental implant complex. J Prosthet Dent, 100(3), 183-193, 2008. https://doi.org/10.1016/S0022-3913(08)60177-8
- Joo YH, Lee JH. A study on accuracy and application of the implant torque controller usec in dental clinic. J Kor Acad Prosthodont, (49)3, 197-204, 2011. https://doi.org/10.4047/jkap.2011.49.3.197
- Kim DS, Lee SH, Her SB, Rhee SH, Yang HC. The effect of cyclic loading on the removal torque between various implant-abutment system. Korean J Dent Mater, 38(3), 197-208, 2011.
- Kim JM. A study of screw loosening after dynamic contious fatigue test of several abutment screw. Graduate School of Seoul University, Master's thesis, 2003.
- Kim NS, Lee MK, Hong MH. A finite element stress analysis of abutment screw according to the implant abutment material. J Kor Acad Dent Tech, 38(1), 1-6, 2016. https://doi.org/10.14347/kadt.2016.38.1.1
- Lang LA, Kang B, Wang R-F, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent, 90(6), 539-546, 2003. https://doi.org/10.1016/j.prosdent.2003.09.012
- Lang LA, Wang R-F, Wang BS, May KB. The Influence of abutment screw tightening on screw joint configuration. J Prosthet Dent, 87(1), 74-79, 2002. https://doi.org/10.1067/mpr.2002.121488
- Lee BH. The study of screw loosening and stress distribution in the jaw bone of different connection types. Graduate School of Yonsei University Master's thesis, 2005.
- Lee BH, Chun HJ, Lee SH, Han CH. Threedimensional finite element analysis of stress distribution and preload of different connection types implant with initial clamping. J Kor Acad Prosthodont, 44(2), 197-206, 2006.
- Lee MK. Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture. J Kor Acad Dent Tech, 38(3), 151-156, 2016. https://doi.org/10.14347/kadt.2016.38.3.151
- Lee MK, Kim KJ. Three dimensional finite element analysis of the stress on supporting bone by the abutment materials of dental implant. J Kor Acad Dent Tech, 40(1), 41-47, 2018.
- Lee MK, Kim YJ, Kim CY. A comparative analysis of stress distribution in the implant supporting bone by occlusal loading location utilizing the finite element method. J Kor Acad Dent Tech, 27(1), 105-113, 2005.
- Nissan J, Gross M, Shifman A, Assif D. Stress levels for well-fitting implant superstructure as a function of tightening force levels, tightening sequence, and different operators. J Prosthet Dent, 86(1), 20-23, 2001. https://doi.org/10.1067/mpr.2001.115182
- Oh DJ, Han MJ, Chung CH. Physical properties for implant abutment screw. Oral Biology Research, 29(3), 53-61, 2005.
- Shin HM, Jeong CM, Jeon YC, Yun MJ, Yoon JH. Influence of tightening torque on implantabtument screw joint stability. J Kor Acad Prosthodont, 46(4), 396-408, 2008.
- Son SS, Kim YJ, Lee MK. Finite element analysis of sress distribution on supporting bone of posterior implant partial denture by loading location. J Kor Aca Dent Tech, 29(1) 93-101, 2007.
- Xia D, Lin H, Yuan S, Bai W, Zheng G. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values. Biomed Mater Eng, 24(6), 2143-2149, 2014.