• Title/Summary/Keyword: Contact Joint

Search Result 551, Processing Time 0.035 seconds

Distribution and clinical features of patients with degenerative change of the mandibular condyle (측두하악장애 환자 중 하악과두의 퇴행성 골 변화를 보이는 환자의 분포 및 임상적 특징)

  • Lim, Yong-Kyu;Kim, Min-Ji;Kim, Youn-Joong;Song, Yun-Heon;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.402-411
    • /
    • 2006
  • Objective: This study was carried out to evaluate the distribution and clinical features of patients with degenerative change of the mandibular condyle. Methods: Six thousand and seventy patients with TMD (temporomandibular cisorder) were selected for this study, who had complete initial clinical records and radiographs. Panorama and TMJ panorama radiographs were used to screen the degenerative change in the condyle, and the patients were divided into DJD (degenerative joint disease) and non-DJD groups. Results: The distribution. and clinical features of the two groups were compared. Out of the total number of patients, 31.7% were in the DJD group, and 68.3% were in the non-DJD group. The portion of females was larger in the DJD group (80.8%) than in the non-DJD group (67.5%), and the DJD group had high prevalence in the second and third decades. Lack of incisal contact, retrusive chin, facial asymmetry, and mouth opening limitation were the chief complaints of the patients who had positive relation to DJD. Conclusion: Patients with an orthodontic treatment history, CO-CR discrepancy and crepitation were at possible risk of having DJD.

Study on the police's protection·support of victims-declaring the Victims Protection years (피해자보호원년을 선언한 경찰의 범죄피해자 보호·지원에 관한 연구)

  • Gong, Jung-Sik
    • Korean Security Journal
    • /
    • no.45
    • /
    • pp.7-35
    • /
    • 2015
  • South Korea's socioeconomic status is high enough to support services for the protection of crime victims. Until now, the Ministry of Justice was the only institution to protect and support the victims, but recently the national police is included. This is considered preferable, since the police is the one to contact the victims first- they can provide immediate support after the incident. Several limits in current laws and crime protection system exist. Therefore, given the importance of protecting victims, model of public-private joint forms should be considered. In premise of establishing a new relationship between the public-private joint system of justice and the maintenance, the range of police's involvement with crime supports will be determined. In the case of developed countries, the police and private organizations maintain close cooperation, appearing as substantial care and support for crime victims. Therefore this study reviews the problems in crime victim protection, assistance from the police stage, and suggest the improvements as follows. The first is to redefine the role of the police who first contacted in the crime victims protection support, the second is to establish a permanent cooperation framework, such as victims specialized police, victims protection agency, the third is to develop services for victim protection available from the police stage, and the fourth, opening Victim Support Center functioning as a temporary accommodation or safety zone for the personal protection of victims. The fifth is to regularize solution conference for victims' protection, and the sixth is to divide of roles in state organization government in charge of victim's protection and local government responsible for victim's support.

  • PDF

Approach to prosthetic treatment for patients with open bite due to mandibular displacement: Case report (하악변위로 인한 개방교합 환자의 보철치료: 증례보고)

  • Seo, Min-Gyung;Chi, Seung-Seok;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.420-430
    • /
    • 2022
  • Open bite is accompanied by decrease in tooth contact and overbite, and causes collapse of occlusal plane, mastication difficulties, speech disorders, changes in appearance, and lower occlusal force than normal. Open bite caused by temporomandibular joint disorder in adults with complete occlusion must be corrected after removal or stabilization of the causative factors. Orthodontic treatment, occlusal adjustment, prosthetic treatment, and surgical treatment can be the option of occlusal correction. This report describes about estimating the cause of occlusion change in two patients who developed an open bite due to mandibular displacement in adults with complete occlusion and different treatment approaches accordingly. In one patient, satisfactory result was obtained in functional and esthetic aspects through occlusal adjustment after stabilization of the temporomandibular joint.

Effect of gender difference and change of load on lower extremity kinetics in step descent (계단 하강 시 성별차이와 중량 변화가 하지역학에 미치는 영향)

  • Seunghyun, Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.1
    • /
    • pp.109-116
    • /
    • 2023
  • The purpose of this study was to investigate the influence of gender and load carriage difference on the lower extremity kinetics during stair descent. Ten healthy males and 10 healthy females were recruited (n=20). In the Maximum resultant velocity, it showed more velocity was decreased with difference by the change of gender (males>females) and load carriage (30%, 20%, 10%> 10%). And, resultant velocity showed interaction between gender and a load (load>gender). Main effect by gender during stair descent showed leg length was decreased in females than that of males at initial contact phase. Also, main effect by gender during stair descent showed more hip, knee flexed and plantar flexion of ankle joint in females than that of males. In the kinetics variables, main effect by gender during stair descent showed more higher reaction force of medial-lateral direction, and leg stiffness in males than that of females. We found that females successfully accommodated a load during stair descent by decreasing the range of motion of the hip joint angle and resultant velocity of movement. Males, on the other hand, require greater medial-lateral, vertical reaction force, and leg stiffness to accommodate a load, and control of momentum.

The Effectiveness and Safety of Dokwhalkisaeng-tang Combined with the Medication on Rheumatoid Arthritis: A Study Protocol for Systematic Review and Meta-analysis (류마티스 관절염 치료제와 병용한 독활기생탕의 효과 및 안전성: 체계적 문헌고찰 및 메타분석 프로토콜)

  • Chae, Soo-Yeon;Jung, Chan-Yung;Kim, Joo-Hee;Kim, Eun-Jung;Seo, Byung-Kwan;Hwang, Min-Seop;Park, Seong-Sik;Kim, Kyung-Ho;Yoon, Jong-hwa;Sung, Won-Suk
    • Herbal Formula Science
    • /
    • v.30 no.2
    • /
    • pp.95-100
    • /
    • 2022
  • Objectives : Recent studies reported that Dokwhalkisaeng-tang (DHJST) could relieve the clinical rheumatoid arthritis (RA) symptoms and the level of RA-related blood test. However, evidence-based review on effectiveness and safety of DHJST with medication on RA was not yet provided. Methods : Searching randomized controlled trials on the use of DHJST for RA will be performed using multiple electronic databases, manual search, and contact to author. Studies will be selected according to the pre-defined criteria and collected data on study participants, interventions, control groups, outcome measurements, the results, adverse events, and risk of bias will be summarized. Primary outcome will be the disease activity score (including effective rate, swollen joint count, tender joint count, and morning stiffness), and the secondary outcomes will be RA-related blood test and adverse events. We will use Review Manager software to perform a meta-analysis, Cochrane Collaboration "risk of bias" tool for assessing the risk of bias, and Grades of Recommendation, Assessment, Development and Evaluation for the determination of quality of evidence. Results : We are going to investigate the effectiveness and safety of DHJST with medication for RA. Conclusion : This study will provide reliable evidence on whether DHJST combined with medicine is more effective on RA than medicine monotherapy.

A comparative study on the fit and screw joint stability of ready-made abutment and CAD-CAM custom-made abutment (기성 지대주와 맞춤형 CAD-CAM 지대주의 적합 및 나사 안정성 비교)

  • Kim, Jong-Wook;Heo, Yu-Ri;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.276-283
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the fit and screw joint stability between Ready-made abutment and CAD-CAM custom-made abutment. Materials and methods: Osstem implant system was used. Ready-made abutment (Transfer abutment, Osstem Implant Co. Ltd, Busan, Korea), CAD-CAM custom-made abutment (CustomFit abutment, Osstem Implant Co. Ltd, Busan, Korea) and domestically manufactured CAD-CAM custom-made abutment (Myplant, Raphabio Co., Seoul, Korea) were fabricated five each and screws were provided by each company. Fixture and abutments were tightening with 30Ncm according to the manufacturer's instruction and then preloding reverse torque values were measured 3 times repeatedly. Kruskal-Wallis test was used for statistical analysis of the preloading reverse torque values (${\alpha}=.05$). After specimens were embedded into epoxy resin, wet cutting and polishing was performed and FE-SEM imaging was performed, on the contact interface. Results: The pre-loading reverse torque values were $26.0{\pm}0.30Ncm$ (ready-made abutment; Transfer abutment) and $26.3{\pm}0.32Ncm$ (CAD-CAM custom-made abutment; CustomFit abutment) and $24.7{\pm}0.67Ncm$ (CAD-CAM custom-made abutment; Myplant). The domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) presented lower pre-loading reverse torque value with statistically significant difference than that of the ready-made abutment (Transfer abutment) and CAD-CAM custom-made abutment (CustomFit abutment) manufactured from the same company (P=.027) and showed marginal gap in the fixture-abutment interface. Conclusion: Within the limitation of the present in-vitro study, in domestically manufactured CAD-CAM custom-made abutment (Myplant abutment) showed lower screw joint stability and fitness between fixture and abutment.

The Development of Third-Rail System Applied to Turn-out Section for Urban Maglev (도시형 자기부상열차 분기기 구간의 제3궤조 전차선 시스템 개발)

  • Min, Byong-Chan;Heo, Young-Tae;Hong, Du-Young;Lee, Won-Joo;Jo, Su-Yeon;Jeong, Nam-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3046-3051
    • /
    • 2011
  • The third-rail system is an important device supplying power directly to the Maglev train through physical contact with the collecting shoe. It is directly related to safety and reliability for the running of Maglev. However, most the third-rail system used in Korea depend on foreign product or technologies, Korea Urban Maglev in the development of appropriate power feeding is urgent. In particular, the turnout section is the weakness point in the system because bending force by turnout section movement and fatigue caused by repetitive motion as well as the expansion by temperature, the forces by Maglev collecting shoe is added th the third-rail. Therefore, this paper proposes the third-rail system appropriate for Korean Urban Maglev of turnout section. To verify the structural stability of POSCO ICT third-rail system, the finite element analysis and physical testing was performed. The third-rail is fixed on each side of the turn-out section steel structure by epoxy insulation supporter and the integral behaviors are occurred. Therefore, the maximum horizontal displacements of each support are investigated and then, it is applied to finite element model of the third-rail to investigate the moments and stress. Also, the bending test about one million times and Expansion Joint for the third-rail was performed. The third-rail system safety and reliability was identified by test line on Korea Institute of Machinery & Materials in Deajeon for under the actual usage environment such as the Maglev and turn-out operation.

  • PDF

Relationship between Neurocognitive Ability and Risk Factors of Anterior Cruciate Ligament Injuries in Female Athletes (여성선수의 신경인지 능력과 전방십자인대 손상 위험요인과의 관계)

  • Ha, Sung-He;Park, Sang-Kyoon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.8
    • /
    • pp.301-309
    • /
    • 2018
  • The aim of this study was to investigate the relationship between the neurocognitive ability and the risk factors of non-contact anterior cruciate ligament injuries during landing in female recreational athletes. Thirty-two female athletes participated in computerized neurocognition test and motion analysis for drop vertical jump. Pearson's linear correlation analysis was performed to analyze the relationship between the raw scores of neurocognition test and biomechanical variables including 3D joint angle, moment, power, vertical ground reaction force, loading rate, and support time. There were correlations between the scores of neurocognition test and biomechanical variables as high the neurocognition score, it also increase landing strategies were used to maintain posture of the lower extremity. Therefore, the neurocognitive test might be used as a good screening method to detect the risk factors before injury.

A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection (철근 콘크리트와 강판 콘크리트 간 이질접합부로 구성된 구조물의 휨 및 전단거동 특성 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Lee, Jong Bo;Won, Deok Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.267-275
    • /
    • 2012
  • This paper describes the experimental study on the structural behavior of the joint plane between a RC(Reinforced Concrete) wall and a SC(Steel Plate Concrete) wall under out-of plane flexural loads and in-plane shear loads. The test specimens were produced with L and I shape to assess efficiently flexural and shear behavior of the structures. In order to consider dynamic loads such as earthquake, cyclic loading tests were carried out. As results of the out-of plane flexural tests, ductile failure mode of vertical bars was shown under a push load and the failure load was more than nominal strength of the specimen. And the latter test was performed to verify the variation which was composition presence of horizontal bars in the SC member. The test results showed that capacity of the specimens was more than their nominal strength regardless of composition presence of horizontal bars.

The Kinematic Analysis of the Hand spring forward and Salto forward straight with 3/2 Turn on the Vault (도마 손 짚고 몸펴 앞 공중 돌아 540도 비틀기의 운동학적 분석)

  • Yeo, Hong-Chul;Yoon, Hee-Joong;Ryu, Ji-Seon;Jung, Chul-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.47-65
    • /
    • 2003
  • The purpose of this study was to investigate the differences of the kinematical and the kinetical factors that calculated from preflight to postflight of salto forward straight 3/2 turn motion between skitters and less-skitters. four S-VHS video cameras operating at 60Hz were used to record the performances. five elite male gymnasts were participated in this study as subjects. three-dimensional coordinates of 20 body landmarks during each trial were collected using a Direct Linear Transformation method. The digitized body landmarks were smoothed using a Butterworth second order with low pass digital filter and a cutoff frequency of 10Hz. 1. A skitter, got a high score for performance, showed shorter time and faster horizontal velocity than a less-skitter at the board contact. also, a skitter extended quickly his knee and hip joint after contacting board for preflight phase. 2. A skitter revealed faster time and horizontal velocity the vault from taking off board than a less-skiller. A skitter took a long time and high distance to get the vertical peak compared with a less-skiller. 3. For the second phase, a skitter, who executes the most optimal motions among the subjects, displayed a long flight time, a high height, and a far flight distance as well as maintaining consistent horizontal speed even at the peak of post flight. On the other side, a less-scorer displayed a slow vertical velocity, distance and a short time at the point of take-off from vault as well as low height at the peak of post flight.