• 제목/요약/키워드: Contact Distance

검색결과 614건 처리시간 0.024초

후방압출에서 펀치형상에 따른 접촉경계면의 표면부하상태 (Surface Stress Profiles at the Contact Boundary in Backward Extrusion Processes for Various Punch Shapes)

  • 노정훈;김민태;비스아라;황병복
    • 소성∙가공
    • /
    • 제18권7호
    • /
    • pp.565-571
    • /
    • 2009
  • This paper is concerned with the analysis on the surface stress profiles of perfectly plastic material in backward extrusion process. Due to heavy surface expansion appeared usually in the backward extrusion process, the tribological conditions along the interface between the material and the punch land are very severe. In the present study, the analyses have focused to reveal the surface conditions at the contact boundary for various punch shapes in terms of surface expansion, contact pressure, and relative movement between punch and workpiece which consists of sliding velocity and distance, respectively. Punch geometries adopted in the analysis include concave, hemispherical, pointed and ICFG recommended shapes. Extensive simulation has been conducted by applying the rigid-plastic finite element method to the backward extrusion process under different punch geometries. The simulation results are summarized in terms of surface expansion, contact pressure, sliding velocity and sliding distance at different reduction in height, deformation patterns, and load-stroke relationship, respectively.

탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성 (760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.

외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정 (Investigation of Standard Error Range of Non-Contact Thermometer by Environment)

  • 김정은;박상웅;최혜경
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

반복 미끄럼 접촉에 의한 표면층의 경화에 대한 해석 (The Analysis for Surface Hardening by Repeated Sliding Contact)

  • 박준목;김석삼
    • Tribology and Lubricants
    • /
    • 제13권4호
    • /
    • pp.71-78
    • /
    • 1997
  • Wear is affected by numerous factors-contact load, sliding velocity and distance, friction coefficient, material properties and environmental conditions. Among these wear factors, surface hardness is one of very important factors to determine wear. But surface hardness is varied by work hardening during repeated sliding contact. In this reason wear rate is increased or decreased with varying surface hardness, and transition of wear mechanism is happened. In this study, the surface hardening by accumulating residual stress was analyzed by considering the repeated sliding Hertzian contact model. The results showed that surface hardness was increased with increasing contact load, friction coefficient and contact number. And the depth of hardening layer, plastic layer and elastic layer depended upon contact load and number, but they didn't depend upon friction coefficient. The predicted surface hardness was about 1.5-1.8 times as hard as the material.

다문화가정자녀에 대한 일반아동의 사회적 거리감에 영향을 미치는 요인 연구 (A Study of factors influencing on Children's Social Distance towards Children from Multicultural families)

  • 윤인성;박선영
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제6권3호
    • /
    • pp.191-202
    • /
    • 2016
  • 사회적 거리감(social distance)은 사회집단에 대한 태도를 측정할 수 있는 개념으로서 취약층의 사회행동 연구에 유용하다. 일반 아동들이 보이는 사회적 거리감이 두드러질수록 다문화가정자녀들의 자신감과 사회적 유능성이 저해될 수 있다. 이에 본 연구는 다문화가정자녀에 대한 일반아동들의 사회적 거리감에 영향을 미치는 요인을 다문화접촉경험, 긍정적 정서와 인지로 본 고정관념, 단일민족의 식을 중심으로 고찰하여 일반아동의 사회적 거리감에 관한 경험적 근거를 제시하고자 하였다. 주요결과는 첫째, 다문화접촉경험 중 높은 친밀도, 외국인 이웃의 인종(특히 백인과 흑인), 미디어와 다문화 교육을 받은 경우가 높은 수준의 사회적 거리감과 관련되었다. 둘째, 다문화가정자녀에 대해 긍정적으로 느끼고 인식할수록 사회적 거리감은 낮아졌다. 셋째, 위계적 회귀분석 결과, 다문화가정자녀에 대한 긍정적 정서, 긍정적 인지가 사회적 거리감을 유의하게 낮추는 효과가 나타났고. 친밀도와 다문화 교육은 사회적 거리감을 오히려 높이는 결과를 보였다. 이러한 결과에 근거하여 다문화가정자녀를 대하는 일반아동의 행동에 관한 사회복지실천을 위한 함의를 제시하였다.

월악산화강암(月岳山花崗岩)의 접촉변성(接觸變成)에 관(關)하여 (Study on The Contact Metamorphism of Weolagsan Granite)

  • 이대성;강준남
    • 자원환경지질
    • /
    • 제11권4호
    • /
    • pp.169-182
    • /
    • 1978
  • The Weolagsan area consists of four units; (1) Low grade meta-sediments of the upper members of Ogcheon age unknown group such as Changri (mainly black slate and phyllitic rock), Majeonri (mainly alternation of slate, limestone and chert) and Hwanggangri Formation (pebble bearing phyllitic sediments); (2) Samtaesan Formation of Chosun System of Ordovician; (3) So called meta-volcanics and (4) Weolagsan Granite and its associations which intruded above mentioned meta-sediments and meta-volcanics. This study was focused to know the Woelagsan granite and its metasomatic effects to the country rocks petrographically and petrochemically. According to the field survey, microscopic work and some chemical analysis, the granite is a "normal granite" based on the Streckeisen's classification and belongs to a mass of the Central-zone younger group in Ogcheon geosynclinal belt. The granite metasomatized the country rocks along its northern contact zone. Zone of calcareous and cherty rocks (Majeonri formation) was silicified partly and skarned locally at the contact with the granite. The chemical analysis of the zone show no difinite variations in contents of $SiO_2$ and CaO with the distance from the granite. It seems to be indicated that the silicification of this part was not so metasomatized by the granite body, but thermally affected as much as to be partially remelted in the specific parts of the formations. Meta-volcanic rock zone was slightly chloritized near contact with the granite. Limestone of Samtaesan Formation was silicified and skarned along the contact zone by the granite body. The chemical analysis of the zone show some noticiable changes in compositions of $SiO_2$ and CaO with distance from the granite boundary. It can be imagined that the silicification of this zone was metasomatically originated by Woelagsan Granite. According to chemical analysis on several trace elements, the ratio of Zn/Cr and Ni/Cr are relatively higher than that of Cu/Cr in the above mentioned silicified zones. Generally the variation of these metal elements in the zones tend to be regular with distance from the granite body.

  • PDF

Minimum cost design for circular isolated footings with eccentric column taking into account that the surface in contact with the ground works partially in compression

  • Inocencio Luevanos-Soto;Arnulfo Luevanos-Rojas;Victor Manuel Moreno-Landeros;Griselda Santiago-Hurtado
    • Coupled systems mechanics
    • /
    • 제13권4호
    • /
    • pp.311-335
    • /
    • 2024
  • This work aims to show a model to estimate the minimum cost (Thickness and area of steel in X and Y directions) for design a circular isolated footing with eccentric column that considers that the surface in contact with the ground works partially under compression. The formulation is shown by integration to find the moments, the bending shears and the punching shear using the pressure volume under the footing. Some researchers show the minimum cost design for circular isolated footings for an eccentric column assuming that the contact area works completely in compression, others consider the contact surface with the ground working partially in compression for a column in the center of the base. Three numerical examples are developed to obtain the complete design, which are: Example 1 for a column in the center of the base,Example 2 for a column at a distance of 1.50 m from the center of the base in the X direction, Example 3 for a column at a distance of 1.50 m from the center of the base in both directions. Also, a comparison of the new model against the model proposed by other authors is presented. The comparison shows that the new model generates a great saving of up to 43.74% for minimum area and 48.44% for minimum cost design in a column located in the center of the base, and when the column is located at a distance of radius/2 starting from the center of the base in the X direction generates great savings of up to 45.24% for minimum area and 31.80% for minimum cost design. Therefore, it is advisable to use the model presented in this study.

PECVD에 의한 TiN 코팅의 마모특성 연구 (Wear Characteristics of TiN Coating by Plasma Enhanced CVD)

  • 송건;안효석
    • Tribology and Lubricants
    • /
    • 제6권1호
    • /
    • pp.116-125
    • /
    • 1990
  • An experimental programme was established to determine the wear behaviour of TiN coatings of thickness 1 $\mu$m and 3 $\mu$m. by PECVD with the variation of applied load, sliding velocity and sliding distance. It was shown that oxidation of transferred metal as sliding speed increased formed oxide film so that it contributed in decreasing the wear rate. With the roller-on-disc tribometer employed, the wear rate of the roller specimen was decreased with the increase in sliding distance due to the reduction in effective contact pressure. Finally, the severe cracks concentrated at the trailing edge of contact surface were explained in terms of high tensile stress prevailing at the trailing edge of the contact and were identified as a dominant wear mechanism as well as the strong local welding between coating layer and the counter surface, leading to the debonding of the coating layer.

GMA 용접의 용착속도에 미치는 Contact-tube와 모재간 거리의 영향 (Effect of Contact-tube to Work Distance on the Melting Rate of GMA Welding)

  • 경규담;이정헌;천홍정;박병희;강봉룡;김희진
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.87-94
    • /
    • 1996
  • It has been well known in GMA welding process that wire feeding speed (WFS) or deposition rate increases linealy with the increase of wire extension. In this investigation, however, such an well-known relationship was .reconsidered in terms of contact-tube to work distance (CTWD) instead of wire extension. To verify the proposed relationship between WFS and CTWD, bead-on-plate welding was performed with various CTWDs in the range of 15∼35mm under the condition of near-constant voltage and current As expected, the test results showed an excellent linear relation between WFS and CTWD. Furthermore, the value of the slope turned out to be quite similar to those of previous investigators obtained either theoretically or experimentally through the Precise measurement of electrode extension. Present result also demonstred that the increase of CTWD could be very practical measure for increaring deposition rate without any increase of heat input Depending on the tip recess the practical maximum of CTWD was appeared to be limited somewhere in 25∼30mm mainly due to the entrappment of porocity.

  • PDF

침수에 의한 누전지역의 자속밀도 영향 (Influence of Flux Density of Electric Leakage Area by Inundation)

  • 최운식;김탁용;김진사
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1109-1113
    • /
    • 2010
  • Recently, important for the safety has been increasing together economic developments. The leakage only is measured by the voltage difference. This method is a way to contact the electric leakage area. It can cause electric shock at users. We propose a non-contact method to detect a short circuit in this paper. We investigate magnetic field at electric leakage area to present non-contact method. Simulated environment created a short circuit in the flooded areas. Voltage is supplied 50, 150 and 200[V]. Magnetic field was measured at 0, 5 and 10[cm]. Magnetic flux was reduced about $0.4[{\mu}T/cm]$ depending on the distance changes in the steady region. But we confirmed that magnetic flux is measured the same value depending on the distance changes in the electric leakage area.