• Title/Summary/Keyword: Construction Standard

Search Result 3,431, Processing Time 0.03 seconds

Durability and Strength of Dense Grate Permeable Concrete Using Silica sand and Flexible Alkyd Resin (유변성(油變性) 알키드 수지(樹脂)와 규사(硅砂)를 사용(使用)한 밀입도(密粒度) 투수(透水)콘크리트의 강도(强度) 및 내구특성(耐久特性))

  • Kim, In-Jung;Hong, Chang-Woo
    • Resources Recycling
    • /
    • v.19 no.6
    • /
    • pp.36-42
    • /
    • 2010
  • Researches on resources recycling in the field of construction have made an extensive progress such as recycled aggregate of waste concrete and recycling of asphalt. On the other hand, there are almost never researches on pavement method with used waste frying oil. In South Korea, 0.2 million ton used waste frying oil is discharged every year. It is guessed that about 0.1 million ton used waste frying oil can be collected. If used waste frying oil is recycled, it is expected that disuse cost will be reduced and water pollution of rivers will be prevented. Therefore, the purpose of the study was to evaluate on mechanical features (strength, water resistance, chemical resistance, abrasion resistance, freezing and thawing resistance and permeable coefficient) whether dense graded permeable concrete mixing silica sand with flexible alkyd resin manufactured by making ester reaction with collected used waste frying oil to make alkyd resin could be applied to road pavement for non-roadway. The results of the study were as follows. In flexural strength, it had 1.6 times as much as road design standard 4.5MPa. In water resistance, chemistry resistance and freezing and thawing resistance, they had lack of strength in early age. As age went by, they didn't have large changes. And curing temperature had phenomenon of increase in strength at rather low temperature than high temperature by glass transition temperature of resin. Therefore, considering workability, strength and durability when it was applied to road pavement, it was reasonable that the mixing ratio of flexible alkyd resin was 10~15% in comparison with silica sand weight.

Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model (축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom;Kwon, Sin-Won;Gil, Kyung-Suk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

Variation of Harbor Oscillations in Youngil Bay (영일만 항만에서의 부진동 변화에 관한 연구)

  • Jeon Min-Su;Lee Joong-Woo;Lee Seung-Chul;Jung Jae-Hyun;Hwang Ho-Dong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.199-206
    • /
    • 2006
  • Today the harbor oscillation problems are the most significant factor to design harbors serving the very large ships. Large vessels moored in the elastic hawsers at the coastal harbors are often displaced due to the resonance between the long period waves and mooring system. The cargo handling may be interrupted and the hawsers may be broken, especially when the amplification becomes remarkable. The most significant harbor which is confronted with harbor oscillation problem in Korea is the Pohang New Port. Many cases of problems are being notified by the pilot association and local office of MOMAF. However, it is difficult to prevent the arrival of long waves causing oscillation within this harbor. Moreover, Government already started new port plan at the mouth of YoungIl Bay without treating problems occurred in the Pohang New Port. This study deals with the variation of harbor oscillation due to the construction of 4.1km breakwater at the bay mouth and new port plan. Numerical method used are fairly standard form from the extended mild slope equation. The obtained numerical results were compared with the field measurement from the previous study and this will bring a certain level of discussion and consideration of variation in the future port development.

  • PDF

A Study on Developing the Model of Reasonable Cost Calculation for Privacy Impact Assessment of Personal Information Processing System in Public Sector (공공기관 개인정보 처리시스템의 개인정보 영향평가를 수행하기 위한 합리적인 대가 산정 모델 개발에 관한 연구)

  • Shin, Young-Jin
    • Informatization Policy
    • /
    • v.22 no.1
    • /
    • pp.47-72
    • /
    • 2015
  • According to the progress of national informatization throughout the world, infringement and threaten of privacy are happening in a variety of fields, so government is providing information security policy. In particular, South Korea has enhanced personal impact assessment based on the law of personal information protection law(2011). But it is not enough to effect the necessary cost calculation standards and changeable factors to effect PIA. That is, the budgets for PIA was calculated lower than the basic budget suggested by Ministry of Government Administration Home affairs(2011). Therefore, this study reviewed the cost calculation basis based on the literature review, cost basis of similar systems, and reports of PIA and obtained to the standard with Delphi analysis. As a result, the standards of PIA is consisted to the primary labors and is utilized to how the weights by division of target system, construction and operating costs of target system, type of target systems, etc. Thus, the results of this study tried to contribute to ensure the reliability of PIA as well as the transparency of the budget for privacy in public sector.

Analysis of quality improvement effects by construction of sewer systems in Nam River Basin (남강 상류유역의 하수도시설 확충으로 인한 하류 수계의 수질개선 효과 분석)

  • Joo, Jin-Gul;Lee, Jung-Ho;Kim, Joong-Hoon;Kim, Eung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.771-778
    • /
    • 2008
  • Effects of establishments of more sewer systems on water quality in Nam River, Deokchun River, and Jinyang Lake were analyzed for various scenarios using QUAL2E, WASP 7 water quality model. Three different scenarios were tested: 1) 20.8% of sewer diffusion rate which is same to the existing condition. 2) Expansion of sewer system to 65.2% which would emit less pollutants, BOD 2350.5 kg/d, TN 216.0 kg/d, TP 44.0kg/d. 3) Pollutants emission to maintain first grade water quality in Nam River, Jinyang Lake, BOD and TN in the case 2 were 7.69%, 2.10% lower than those in the case 1 in the Nam River. And in the Jinyang Lake, BOD, TN, and TP in the case 2 were 10.25%, 1.37%, 2.94% lower than those in the case 1. However the simulations showed that water quality could not hold down first grade water quality standard level with the establishments of more sewer systems. To satisfy the criteria in the Nam River and Jinyang Lake, BOD emission must be reduced 27.2%, 37.05% compared to those in the case 1.

Determination of operating offline detention reservoir considering system resilience (시스템 탄력성을 고려한 빗물저류조 운영수위 결정)

  • Lee, Eui Hoon;Lee, Yong Sik;Jung, Donghwi;Joo, Jin Gul;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.403-411
    • /
    • 2016
  • Recently, the number of occurrences of inundation and the severity of flood damage has increased rapidly as the frequency of localized heavy rainfall and the ratio of impervious area increased in urban areas. Most local governments focus on employing structural measures (e.g., the construction of detention reservoirs/pump stations, rehabilitation of drainage and sewer pipes) to prevent urban inundation. On the other hand, the effectiveness of implementing such structural measures is being dimished because there are already many inundation prevention facilities. The limitation of structural measures can be overcoming by employing non-structure measures, such as flood alerts and the operation of drainage facilities. This study suggests the pump operation rule (i.e., suggesting pump stop level) for a new detention reservoir operating method, which triggers the operation of a pump based on the water level at the monitoring node in urban drainage system. In the new reservoir operation, a total of 48 rainfall events are generated by the Huff distribution for determining the proper pump stop level. First, the generated rainfall events are distributed as frequencies, quartiles, and durations. The averaged system resilience value was determined to range from 1.2 m to 1.5 m is based on the rainfall-runoff simulation with rainfall generated by the Huff distribution. In this range, 1.2 m was identified considering the safety factor of 1.25 by the Standard on sewer facilities in 2011.

Preparation and Characterization of Polyurethane Waterproof Coatings Containing Fly Ash

  • Lee, Sung-Il;Kim, Duk-Bae;Yang, Go-Su;Kim, Wan-Young;Byoun, Youn-Seop;Lee, Youn-Sik
    • Elastomers and Composites
    • /
    • v.38 no.3
    • /
    • pp.243-250
    • /
    • 2003
  • Polyurethane waterproof (PW) coatings are increasingly demanded in Korea for repairing cracks on old building roofs and construction of many sporting facilities. Calcium carbonate, a common filler, is incorporated in PW compositions. In this study, PW coatings were prepared by substituting a part of calcium carbonate with fly ash. The maximum amounts of calcium carbonate which can be substituted by fly ash obtained in the cyclone and bag filter dust collectors were 20 and 10%, respectively. It was found that the curing rate of PWs ran be controlled by varying the amount of Pb-octoate catalyst. The elongations at break as well as tensile strength and tear strength of PW coatings containing fly ash could also be adjusted such that their values were comparable to those of a standard PW coating by varying relative amounts of some components. However, the amount of cadmium, mercury, and lead leached from PW coatings containing fly ash obtained from the bag filter collector exceeded the respective allowed upper limits, mainly due to the initial high contents of them in the fly ash. On the other hand, PW coatings containing fly ash obtained from the cyclone collector exhibited better mechanical properties and did not release any significant amounts of the heavy metals. Thus, it was concluded that PW coatings containing fly ash can be utilized for practical applications as long as an appropriate fly ash is used.

Pillar stability in very near-twin tunnels (초근접 병설터널의 필라 안정성 확보)

  • Kim, Donggyou;Koh, Sungyil;Lee, Jeongyong;Lee, Chulhee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.699-714
    • /
    • 2022
  • The objective of this study is to suggest a safe and economical pillar reinforcement method when very near-twin tunnels with a minimum interval of 1 m passes through a soft zone such as weathered soil or weathered rock. A standard cross-sectional view of a two-lane road tunnel was applied to suggest a pillar reinforcement method for the very near-twin tunnels. The thickness of the pillar was 1 m. The ground condition around the tunnel was weathered soil or weathered rock. There were four reinforcement methods for pillar stability evaluation. These were rock bolt reinforcement, pre-stressed steel strand reinforcement, horizontal steel pipe grouting reinforcement, horizontal steel pipe grouting + prestressed steel strand reinforcement. When the ground condition was weathered soil, only the pillar reinforced the horizontal steel pipe grouting + prestressed steel strand did not failed. When the ground condition was weathered rock, there were no failure of the pillar reinforced the horizontal steel pipe grouting or the horizontal steel pipe grouting + prestressed steel strand. It is considered that the horizontal steel pipe grouting reinforcement played a role in increasing the stability of the upper part of the pillar by supporting the upper load applied to the upper part of the pillar.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Analysis of Sand Water Ratio and Drying Unit Weight Using Flat TDR System (Flat TDR 시스템을 이용한 모래의 함수비와 건조단위중량 분석)

  • Lee, Junesung;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.333-342
    • /
    • 2021
  • In this study was conducted to measure the water content and dry unit weight of the ground using TDR (Time Domain Reflectometry) in order to supplement the problems of the conventional compaction management method. The Flat TDR system is a device that does not cause ground disturbance, and in order to verify the measured values, the dry density and water content were measured for samples of the ground subject at 7 sites other than Jumunjin Standard Temple. The water content section was divided into 6 sections of 3, 6, 9, 12, 15, and 18%, and the experimental results were confirmed according to the unified classification method. As a result of the indoor experiment, the water content showed an error of about 0.7% for the SP sample and about 1.3% for the SM sample. In addition, the dry unit weight confirmed an error of about 7% for the SP sample and about 5% for the SM sample. It was confirmed that stable values were derived in sandy or silty sandy ground except for clay or gravel. Through the experimental results, it was confirmed that the measured values of the flat TDR system derive similar values to the existing traditional compaction management method, and it was determined that the flat TDR equipment was suitable for construction sites that require quick constructability and economic feasibility.