• Title/Summary/Keyword: Construction Capacity

Search Result 2,805, Processing Time 0.036 seconds

The Study on Estimation of The Transformer Capacity of Housing and Economic Evaluation Using Case Studies (공동주택 변압기용량 적정 산정을 위한 수용률 개선 및 사례 연구를 통한 경제성 평가)

  • Lee, Yun-Sang;Seo, Jung-Youl;Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.142-149
    • /
    • 2010
  • Interest in energy efficiency and savings have been rising internationally. For this reason, the domestic housing construction in the area of power equipment is being actively studied. Currently approximately 400,000 per year of domestic housing is being built. Applies to housing construction during the current transformer capacity low utilization and load factor has been applied has been designed. In other words, excessively high reserve capacity has been applied. According to this problem, initial facility costs and power losses will cause because transformer low utilization be appropriated. Thus, the energy efficiency drops. In this paper, analysis of past utilization of the housing transformer, and applying an appropriate demand factor has been analyzing the energy loss reduction. this analysis of current domestic conditions for the proper housing transformer scheme is to calculate the capacity.

A Study on the Shear Strengthening Effect of Reinforced Concrete Beams with Structural Damage (구조적 손상을 입은 철근콘크리트 보의 전단보강 효과에 관한 연구)

  • Shin, Yong-Seok;Kim, Jeong-Hoon;Kim, Jeong-Sup;Kim, Kwang-Seok;Cho, Cheol-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.5
    • /
    • pp.43-51
    • /
    • 2008
  • This study examines shear capacity performance and structural characteristics of reinforced concrete beam using carbon fiber sheet(CFS), g)ass fiber sheet(GFS), glass fiber steel plate(GSP) and carbon fiber bar CB) which are reinforcing materials for reinforced concrete beam in order to produce similar condition to repair and reinforce actual structure and aims to provide data available In designing and constructing reinforced concrete structures under the structural damage. This study obtains the following conclusions. After considering the shear experiment results. it was indicated that the CB reinforced test object was the best in the shear capacity improvement and ductility capacity as it was contained in the concrete and was all operated, Also, GFS reinforced test object indicated the reduced flexural capacity but good shear capacity. GSP reinforced test object had bigger reinforcing strength than other reinforcing test objects. On the other hand, it showed the lowest reinforcement effect as compared section thickness of reinforced material because it showed the bigger relativity a section thickness of reinforced material. If the adherence to the concrete is improved, it will seem to show bigger reinforcement effect.

Evaluation of the Load Carrying Capacity of Existing Bridges Using Buckling Equation With Initial Deflection (초기처짐을 갖는 좌굴방정식을 이용한 교량의 내하력 평가)

  • Ki, Wan-Seo;Yang, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2032-2037
    • /
    • 2009
  • The load carrying capacity of bridge structures in public use is generally evaluated without considering their actual behavioral characteristics. This study examined common errors taking place in the evaluation of load carrying capacity of bridge structures. In order to account for their current behavioral characteristics such as the boundary condition, we evaluated the load carrying capacity of a bridge in terms of axial force, which was calculated by applying deflection to the buckling equation for members with initial imperfections, and in terms of bending moment obtained from deflection.

Determination of the load carrying capacity of closed steel supports used in underground construction and mining

  • Lenka, Koubova;Petr, Janas;Karel, Janas;Martin, Krejsa
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.715-728
    • /
    • 2022
  • Closed steel supports of different shapes are used in mining and underground constructions. The supports are prefabricated from rolled, usually robust, steel profiles. The load carrying capacity of a support is considerably influenced by the active loading and passive forces. The passive forces are induced by interactions between the support and the surrounding rock mass. The analysis herein comprises three parts: The first part consists of structural geometry processing. The second part involves finding the numerical solution of a statically indeterminate structure for a specified load. The third part is calculation of the load carrying capacity and the components of internal forces and deformations. For this, the force method and numerical integration are used. The Winkler model is applied when the support interacts with the surrounding environment. The load carrying capacity is limited by the slip resistance of the connected parts and it is limited by reaching the ultimate state of the profile. This paper serves as a comprehensive reference for the determination of the load carrying capacity of closed steel supports and includes stepwise derivations of the governing formulas.

A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities (의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

VALUATION OF A MULTI-STAGE RAINWATER HARVESTING TANK CONSTRUCTION USING A REAL OPTION APPROACH

  • Byungil Kim;Hyoungkwan Kim;SangHyun Lee
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.386-389
    • /
    • 2013
  • Under climate change and urbanization, rainwater harvesting (RWH) systems are emerging as an alternative source of water supply because of growing concern about water sustainability. RWH systems can satisfy the various watering needs and provide the environmental benefits of lessening the damages from flood, drought, and runoff. The economic success of a RWH system is vitally concerned with the determination of the design capacity of storage tank to be built in the system. The design capacity is determined by the factors of average annual rainfall, period of water scarcity, and water price during the whole life-cycles. Despite the high uncertainties inherent in these factors, the current engineering design of RWH system construction often assumes that storage tanks should be built all at once. This assumption implicitly ignores the managerial flexibility in responds to the future as new information comes out-the right to build storage tanks stage by stage depending on the evolution of demand. This study evaluates the value of a multistage storage tank construction using a real option approach. A case study involving a typical RWH system construction in Jeonju, the Republic of Korea is conducted. The managerial flexibility obtained from the real option perspective allows engineers to develop investment strategies to better cope with the issue of water sustainability.

  • PDF

Analyzing the Competence of Construction Engineers in Apartment Construction (아파트 공사에서의 건설기술자 역량 분석 연구 - 공무업무를 중심으로 -)

  • Kim, Hu Yong;Kim, Yea Sang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.14-23
    • /
    • 2018
  • In the domestic construction industry, large-scale housing construction projects are being carried out by construction companies with competitiveness in the domestic top 10, it is said that the competence of the construction engineer is a factor for the success of the project. In Korea, there is National Competency Standards (NCS) that systematize contents of knowledge, technology, and attitude required in order to perform job in industrial field as the importance of individual ability is systemized in the country. Therefore, in this study, defined the detail competence in construction administration works, and examined the level of competence and degree of impotance detailed competency of construction engineers using AHP analysis & ANOVA. As a result, it was found that the current capacity of the Engineers in the apartment construction work is insufficient compared to the level of the competence they think they have, and that they have different competencies depending on their work experience and job position. This means that if the career is accumulated, the capacity that is possessed naturally will be changed. Therefore, it will be necessary to improve the capacity of the construction engineers who have a short work experience and a low job level.

Estimation of Bearing Capacity of SIP Pile Installed by Improved Criteria (개선된 기준으로 시공된 SIP 말뚝의 지지력 평가에 관한 연구)

  • Park, Jong-Bae;Kim, Jung-Soo;Lim, Hae-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.3
    • /
    • pp.5-15
    • /
    • 2004
  • SIP has been widely used as a low noise and vibration piling method in Korea. But the quality control of SIP was not properly settled down and field workers did not fully understand the principle of SIP method. So not a less troubles were raised at construction site and bearing capacity was not fully mobilized. To settle these problems, Korea National Housing Corporation amended the construction and load test criteria of SIP in 2002. After load tests on the SIPs installed in field according to the new criteria, we found that the bearing capacity in field vs the design load ratio increased and bearing characteristics was enhanced than that installed by the former criteria. To consider the enhanced bearing characteristics in the pile design and determine the adequate design criteria, this paper analyzed the accuracy of design criterion which were commonly used in Korea comparing with the load test results. Analysis result shows that Meyerhof criteria(1976) properly simulates the bearing capacity of SIP installed by the new construction and load test criteria.

  • PDF

Evaluation of Load-Carrying Capacity Loss due to Corrosion in Thin-Walled Section Steel Members (판폭두께비가 큰 휨부재의 부식발생에 따른 구조성능평가에 관한 연구)

  • Chung, Kyung Soo;Park, Man Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.619-626
    • /
    • 2009
  • The use of thin-walled flexural members has proven to be a practical way to achieve the lowest cost in the construction of prefabricated long-span, low-rise building frames in steel. On the other hand, most of these structures are subjected to corrosion due to environmental exposure, which can reduce their carrying capacity. Corrosion damage is a serious problem for these structures as it causes thickness loss. That is, the class of a section (plastic, compact, non-compact, or slender) may change from one to another due to the loss of thickness of the compression flange and web due to corrosion. In this study, the effects of corrosion on thin-walled members in long-span steel frames were evaluated with regard to the moment-rotation curve, initial stiffness, maximum load capacity, stiffness in the post-maximum capacity, and energy absorption.

Experimental Performance Verification of Load Carrying Capacity Algorithm of Bridges using Ambient Vibration (상시진동을 이용한 교량 내하력 추정 알고리즘의 실험적 성능 검증)

  • Lee, Woo-Sang;Park, Ki-Tae;Han, Sung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.83-90
    • /
    • 2010
  • In this study, it is conducted that the performance verification of the ambient load carrying capacity algorithm using long-term measurement systems of bridges. For this purpose, a steel-box type model bridge is fabricated and the public load carrying capacity of a steel-box model bridge is estimated by conducting the numerical analysis and load test. In addition, we compare the public load carrying capacity with the estimated result of a steel-box model bridge using the ambient load carrying capacity algorithm. By the assessment result, it is shown that the estimated ambient load carrying capacity is the difference of approximately 6.0 percentages as compared with the public load carrying capacity.