• 제목/요약/키워드: Constant temperature and humidity test

검색결과 50건 처리시간 0.028초

잔골재 특성에 따른 콘크리트 건조수축 모델링에 관한 연구 (A Study on Modelling for Prediction of Concrete Drying Shrinkage according to Properties of Aggregate)

  • 박도경;양극영
    • 한국건축시공학회지
    • /
    • 제6권1호
    • /
    • pp.73-77
    • /
    • 2006
  • Drying Shrinkage has much complexity as it has relations with both internal elements of concrete and external factors. Therefore, experiments on Concrete Drying Shrinkage are carried out in this study under simplified circumstances applying temperature & Humidity test chamber which enables constant temperature and humidify. Comparative analyses have been made respectively according to the consequences aiming at modelling for prediction of Concrete Drying Shrinkage and making out measures to reduce it. As a result Strain Rate of Drying Shrinkage of concrete was measured to increase by average $10{\times}10^{-5}$ in proportion to additional 4% increase in fine aggregate ratio, when water/cement ratio constant. Strain Rate of Drying Shrinkage in pit sand concrete increased 20% higher than measured when in river sand under the condition of 90-day material age. 6. Strain Rate of Drying Shrinkage in sea sand concrete increased $10%{\sim}15%$ higher than measured when in river sand. The results of prediction of Rate of Drying Shrinkage by Response Surface Analysis are as fellows. The coefficient of correlation of Drying Shrinkage in concrete was over 90%.

PVA 시멘트 혼합토의 공학적 특성 연구 (A Study on the Engineering Characteristics of PVA (Polyvinyl Alcohol) Fiber-Cement-Soil Mixtures)

  • 김영익;연규석;김기성;유경완;김용성
    • 한국농공학회논문집
    • /
    • 제53권2호
    • /
    • pp.35-43
    • /
    • 2011
  • This study aimed to investigate the engineering characteristics of PVA fiber-cement-soil mixture used to prevent or reduce brittle failure of cement-soil mixtures due to the tensile strength increase from the addition of a synthetic fiber. The engineering characteristics of PVA fiber-cement-soil mixtures composed of PVA fiber, soil, and a small amount of cement was analysed on the basis of the compaction test, the unconfined compression test, the tensile strength test, the freezing and thawing test, and the wetting and drying test. The specimens were manufactured with soil, cement and PVA fiber. The cement contents was 2, 4, 6, 8, and 10%, and the fiber contents was 0.4, 0.6, 0.8, and 1.0% by the weight of total dry soil. To investigate the strength characteristics depending on age, each specimen was manufactured after curing at constant temperature and humidity room for 3, 7 and 28 days, after which the engineering characteristics of PVA fiber-cement-soil mixtures were investigated using the unconfined compression test, the tensile strength test, the freezing and thawing test, and the wetting and drying test. The basic data were presented for the application of PVA fiber-cement-soil mixtures as construction materials.

TESTS FOR VARYING-COEFFICIENT PARTS ON VARYING-COEFFICIENT SINGLE-INDEX MODEL

  • Huang, Zhensheng;Zhang, Riquan
    • 대한수학회지
    • /
    • 제47권2호
    • /
    • pp.385-407
    • /
    • 2010
  • To study the relationship between the levels of chemical pollutants and the number of daily total hospital admissions for respiratory diseases and to find the effect of temperature/relative humidity on the admission number, Wong et al. [17] introduced the varying-coefficient single-index model (VCSIM). As pointed out, it is a popular multivariate nonparametric fitting technique. However, the tests of the model have not been very well developed. In this paper, based on the estimators obtained by the local linear technique, the average method and the one-step back-fitting technique in the VCSIM, the generalized likelihood ratio (GLR) tests for varying-coefficient parts on the VCSIM are established. Under the null hypotheses the new proposed GLR tests follow the $\chi^2$-distribution asymptotically with scale constant and degree of freedom independent of the nuisance parameters, known as Wilks phenomenon. Simulations are conducted to evaluate the test procedure empirically. A real example is used to illustrate the performance of the testing approach.

u-EMS : 센서네트워크 기반의 가축매몰지 악취환경정보 실시간 모니터링 시스템 설계 및 구현 (The Design and Implementation of a Real-Time FMD Cattle Burial Sites Monitoring System Based-on Wireless Environmental Sensors)

  • 문승진;김홍규;박규현
    • 한국통신학회논문지
    • /
    • 제36권12B호
    • /
    • pp.1708-1721
    • /
    • 2011
  • 최근 구제역과 같은 가축질병으로 인한 살 처분된 가축매몰지의 적절한 모니터링 시스템의 필요성이 대두되고 있다. 그러나 현재 사용되는 모니터링 시스템은 살 처분된 매몰지 현장에서의 시료를 채취한 후 1~2주간의 모니터링 기간을 필요로 함으로 실시간 감시가 필요로 하는 매몰지에 대한 연속측정이 불가능하다. 이에 본 논문에서는 이런 실시간 모니터링을 가능하게 하는 우선 센서네트워크 기반의 가축매몰지 환경정보 모니터링 시스템 설계 및 구현을 제안한다. 제안된 시스템의 무선 센서노드는 환경센서(Dust, Co2, NH3, H2s, Temperature, Humidity)와 위치확인을 위한 GPS센서로 구성된다. 제안된 시스템은 게이트웨이를 통해 원격지 서버에 전송된 매몰지 환경정보를 분석함으로 언제 어디에서나 유해환경 모니터링이 기능하고 위치확인을 통한 상황에 따른 능동적인 대응을 가능케한다. 따라서 제안된 시스템의 유효성 검증을 위해 규정된 가스 배출관에 센서를 설치하였고, 통합 모니터링이 가능한 테스트 베드에서 실시간으로 수신된 데이터를 수집, 분석하여 시간의 변화에 따른 매몰지 위치의 악취환경변화를 모니터링 하였다. 이를 통한 상황에 따른 실시간 대응을 함으로 유사시 환경오염의 사전예방이 가능 한 것을 확인할 수 있었다.

굴절률 가변에 따른 silicon nitride 박막의 항온/항습 신뢰성 연구 (A study on refractive index of silicon nitride thin film according to the variable constant temperature and humidity reliable research)

  • 송규완;장주연;이준신
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.56.1-56.1
    • /
    • 2010
  • 결정질 실리콘 태양전지의 표면 ARC(Anti-reflection Coating)layer는 반사도를 줄여 광 흡수율을 증가시키고, passivation 효과를 통하여 표면 재결합을 감소 시켜 태양전지의 효율을 높이는 중요한 역할을 한다. Silicon nitride 박막은 외부 stress 요인에 대해 안정성을 담보할 수 있어야한다. 따라서, 본 연구에서는 굴절률 가변에 따른 silicon nitride 박막을 PECVD를 이용하여 증착하고, 항온/항습 stability test를 통해 박막의 안정성을 확인하였다. Silicon nitride 증착을 위해 PECVD를 이용하였고, 공정압력 0.8Torr, 증착온도 $450^{\circ}C$, 증착파워 300W에서 실험을 진행하였다 박막의 굴절률은 1.9~2.3의 범위로 가변하였다. 항온/항습에 대한 신뢰성을 test 하기 위하여 5시간동안의 test를 1cycle로 하여 20회 동안 실험을 실시하였다. 증착된 silicon nitride 박막의 lifetime은 firing 이후 57.8us로 가장 높았으며, 항온/항습 test 이후에도 유사한 경향을 확인 할 수 있었다. 또한, 100h 동안의 항온/항습 test 결과 silicon nitride 박막의 lifetme 감소는 8.5%에 불과했다. 본 연구를 통하여 온도와 습도의 변화에 따른 결정질 실리콘 태양전지의 SiNx 박막의 증착 공정 조건에 대한 신뢰성을 확인 할 수 있었다.

  • PDF

자동차 전장부품의 초 가속 실뇌성 수명시험 방법에 관한 연구 (The Study on the High Acceleration Life Test Method for the Automotive Electric and Electronic Parts)

  • 이종범;조재립
    • 품질경영학회지
    • /
    • 제28권4호
    • /
    • pp.16-28
    • /
    • 2000
  • Recently days, High Accelerated Life Test of electrical and electronic parts is increasing its importance. This study set the hypothesis to develop the method that was analysis and application of HALT for the automotive electrical and electronic parts, it used Arrhenius's Model and Eyring's Model, and ESS theory. Validity of application is proved by other test data. Especially, this study emphasis on utility of acceleration to temperature, humidity, voltage, mechanical stress and other stress. In this study set the pattem of practical application. Therefore, this study emphasis on the application of the HALT and the use of other parameter by acceleration reliability test data. The result of this study is as follows. 1) There is relationship between molar weight and material constant. 2) Characteristic of material is operating acceleration factor as well as parts failure factors. Of course, according to the characteristic of material, activation energy is often more important than molar weight. But it will be defined by more testing and improvements in practical application.

  • PDF

광학면 연마기의 OMM을 위한 Hartmann Test 방법 연구 (A Study on a Hartmann Test of Optical Mirror for On-Machine Measurement of Polishing machine)

  • 김옥현;이응석;오창진;김용관
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.40-45
    • /
    • 2004
  • Recently, aspheric optical lenses and mirrors, which are harder to manufacture and measure than the conventional spherical ones, are widely used, particularly in electronic fabrication process. Generally, interferometric optical method is used for the measurement of spherical optical surface. However, the interferometric method for aspheric surface measurement is difficult because it needs a precise null corrector and strict environmental conditions such as constant temperature, humidity and vibrations. We have been studied on the manufacturing of aspheric optics to improve the surface profile accuracy and productivity using a corrective polishing process. For the corrective polishing, a practical method of On-Machine Measurement (OMM) is required. For this purpose, an optical OMM system has been studied using the Shach-Hartmann test, which is very robust to the practical polishing environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by the least squares fitting. The measured result of the OMM system shows that the maximum deviation is less than 200 nm for the one of commercial Fizeau interferometer Wyko 6000.

Personal Computer를 이용한 環境因子의 計測 및 制御 System에 관한 연구 (Personal Computer Based System for the Measurement and Control of Environmental Factors)

  • Lee, Hyeong-Choon;Kim, Tae-Sik
    • 한국환경보건학회지
    • /
    • 제13권1호
    • /
    • pp.35-40
    • /
    • 1987
  • Personal computer based measurement and control system was constructed and tested in order to fiexibly apply it to laboratoy experiments in which environmental factors such as temperature, humidity, pH, DO and gases should be measured and controlled. Personal computer FC-80 was successively interfaced to the input-output system made up of PPI, A/D converter, D/A converter, programmable timer and USART boards. To test the system, pH control experiment was executed and the pH of the solution could be measured, expressed on the monitor and controlled at constant value.

  • PDF

고온고습환경이 Sn계 무연솔더의 부식 및 기계적 특성에 미치는 영향 (Effects of High Temperature-moisture on Corrosion and Mechanical Properties for Sn-system Solder Joints)

  • 김정아;박유진;오철민;홍원식;고용호;안성도;강남현
    • Journal of Welding and Joining
    • /
    • 제35권3호
    • /
    • pp.7-14
    • /
    • 2017
  • The effect of high temperature-moisture on corrosion and mechanical properties for Sn-0.7Cu, Sn-3.0Ag-0.5Cu (SAC305) solders on flexible substrate was studied using Highly Accelerated Temperature/Humidity Stress Test (HAST) followed by three-point bending test. Both Sn-0.7Cu and SAC305 solders produced the internal $SnO_2$ oxides. Corrosion occurred between the solder and water film near flexible circuit board/copper component. For the SAC305 solder with Ag content, furthermore, octahedral corrosion products were formed near Ag3Sn. For the SAC305 and Sn-0.7Cu solders, the amount of internal oxide increased with the HAST time and the amount of internal oxides was mostly constant regardless of Ag content. The size of the internal oxide was larger for the Sn-0.7Cu solder. Despite of different size of the internal oxide, the fracture time during three-point bending test was not significantly changed. It was because the bending crack was always initiated from the three-point corner of the chip. However, the crack propagation depended on the oxides between the flexible circuit board and the Cu chip. The fracture time of the three-point bending test was dependent more on the crack initiation than on the crack propagation.

파괴적 가속열화시험 데이터의 분산가정에 따른 수명비교 (Comparison of Storage Lifetimes by Variance Assumption using Accelerated Degradation Test Data)

  • 김종규;백승준;손영갑;박상현;이문호;강인식
    • 한국군사과학기술학회지
    • /
    • 제21권2호
    • /
    • pp.173-179
    • /
    • 2018
  • Estimating reliability of a non-repairable system using the degradation data, variance assumption such as homogeneity (constant) or heteroscedasticity (time-variant) could affect accuracy of reliability estimation. This paper showed reliability estimation and comparison results under normal conditions using accelerated degradation data obtained from destructive measurements, according to variance assumption of the data at each measurement time. Degradation data from three accelerated conditions with stress factors of temperature and humidity were used to estimate reliability. The $B_{10}$ lifetime was estimated as 1243.8 years by constant variance assumption, and 18.9 years by time-variant variance. And variance assumption provided different analysis results of important stresses to reliability. Thus, accurate assumption of variance at each measurement time is required when estimating reliability using degradation data of a non-repairable system.