• Title/Summary/Keyword: Constant current test

Search Result 272, Processing Time 0.026 seconds

Electrochemical Performance on the H3BO3 Treated Soft Carbon modified from PFO as Anode Material (음극소재로 PFO에서 개질된 붕산처리 소프트 카본의 전기화학적 성능)

  • Lee, Ho Yong;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.746-752
    • /
    • 2016
  • In this study, soft carbon was prepared by carbonization of carbon precursor (pitch) obtained from PFO (pyrolysis fuel oil) heat treatment. Three carbon precursors prepared by the thermal reaction were 3903 (at $390^{\circ}C$ for 3 h), 4001 (at $400^{\circ}C$ for 1 h) and 4002 (at $400^{\circ}C$ for 2 h). After the prepared soft carbon was ground to a particle size of $25{\sim}35^{\circ}C$, the soft carbon was synthesised by the chemical treatment with boric acid ($H_3BO_3$). The prepared soft carbon were analysed by XRD, FE-SEM and XPS. Also, the electrochemical performances of soft carbon were investigated by constant current charge/discharge test, cyclic voltammetry and impedance tests in the electrolyte of $LiPF_6$ dissolved inorganic solvents (EC:DMC=1:1 vol%+VC 3 wt%). The coin cell using soft carbon of $25{\sim}35^{\circ}C$ with 3903 soft carbon ($H_3BO_3$/Pitch=3:100 in weight) has better initial capacity and efficiency (330 mAh/g, 82%) than those of other coin cells. Also, it was found that the retention rate capability of 2C/0.1C was 90% after 30 cycles.

A Study on Composition of Solvent Thinners and Evaporation in the Air (일부 신나의 구성성분과 공기중 증발에 관한 연구)

  • Zoh, Kyung Ehi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.245-263
    • /
    • 1997
  • For twelve solvent thinners, evaporation rates of components were investigated and models to estimate the actual concentration have been evaluated. Also, the current ACGIH TLVs (Threshold Limit Values) for the concentration of organic mixtures have been adjusted. The results of this study are summarized as follows : 1. Airborne concentrations of solvent thinner components were related to their respective vapor pressure (r=0.96). On the other hand, there was no significant relation between the concentrations in the air of the thinner compounds and the original amount in liquid form. 2. Airborne concentrations of each chemical were estimated by temperature at $8.5{\pm}1$, $16.7{\pm}1$ and $31.5{\pm}2^{\circ}C$ with an air velocity of 1.5 m/s. The concentrations were increased by increasing temperature (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl acetate, n-butyl alcohol, m-xylene, p-xylene and o-xylene showed a clear relationship to temperature. 3. Airborne concentration of each chemical was estimated by air velocity at 0.05, 1.50 and 2.50 m/s, with a constant temperature at $17{\pm}2^{\circ}C$. The concentrations were increased by increasing air velocity (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl alcohol, m-xylene and p-xylene showed a clear relationship to velocity. 4. In estimating the concentrations of solvent thinners by temperature and air velocity, ACGIH TLVs for mixtures tended to be larger than the values obtained by ACGIH exposure index. It shows that ACGIH TLVs for mixtures are not adequate for evaluating the airborne concentration of thinners and other organic mixtures. 5. The evaporation rate of the thinners were compared to the theoretical equations of Hummel, Braun and Mackay. The Hummel and Braun methods were close to exposure index but Makay's showed an underestimated value. In order to see the accuracy of each three models, the SSE (Error Sum of Squares) calculated for Hummel's was 1.73, being the closest to the actual values. 6. Present ACGIH TLVs for mixtures are not appropriate evaluate industrial environments. In this study, a correction of TLVs using vapor pressure of respective components was suggested. In order to evaluate the corrected TLVs a paired t-test was performed. There was no significant difference between the exposure index and the concentration over suggested TLVs (p>0.05). Thus, this corrected TLVs seem appropriate in order to evaluate actual industrial workplaces organic chemical concentration in the air.

  • PDF

Behavior of Wide Beam-Column Interior Joint with Slab (횡력을 받는 넓은 보-기둥 내부 접합부의 거동 평가)

  • Lee, Bum-Sik;Park, Seong-Sik;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.433-449
    • /
    • 2012
  • An experimental investigation was conducted to study the behavior of RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were the ratio of column-to-beam flexural capacity ($M_r={\Sigma}M_c/{\Sigma}M_b$ ; 0.77~2.26), ratio of the column-to-beam width (b/H ; 1.54, 1.67). Test results are shown that (1) the current design code and practice for interior joints(type 2) are apply to the wide beam-high strength concrete column. (2) the presence of a slab have an effect on the performance of the wide beam-high strength concrete column interior joints(type 2). therefore in the design of the wide beam-high strength concrete column interior joints(type 2), the width of slab effective as a T beam flange should be considered. It was show that the case of the ratio of column-to-beam flexural capacity is more than 2.0, the effective width of slab are 2 times of an effective depth of wide beam, however if the ratio of column-to-beam flexural capacity is 1.4~2.0, the effective width of slab are not able to be considered.

Structural Integrity Evaluation of Mechanically Fastened FRP Beams Under the Effects of Sustained Loads and Environments (지속하중과 환경영향을 받은 MF-FRP 보강보의 구조건전성 평가)

  • Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Mechanically fastening FRP (MF-FRP) strips using nails and anchors, has been shown to provide a more ductile behavior to the strengthened structural element than using bonded FRP. To further advance the state of the knowledge on this strengthening method, the current study examined environmental effects for six months on MF-FRP beams. Reinforced concrete beams strengthened with mechanically fastened FRP strips and subjected to sustained loads for six months were exposed to outdoor weather and constant high temperatures ($40^{\circ}C$). For comparison, the behavior of RC beam with and without sustained loads was evaluated. Results from flexural tests did not show any significant degradation or change of failure mode as a result of sustained load and of environmental effects such as high temperatures and outdoor weather over a period of six months. Failure of the beams was governed by FRP delamination followed by concrete crushing as not much load applied to the nail and anchors because of slip effects.

Study on the Analysis of Damage Patterns of Cellular Phone Batteries According to Energy Sources (에너지원에 따른 이동전화기 배터리의 소손패턴 해석에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.21-26
    • /
    • 2011
  • The purpose of this paper is to present the damage patterns of cellular phone (SCH_W830) batteries according to energy sources and have them utilized as data for the settlement of disputes between manufactures and consumers. The reliability was secured by maintaining the ambient temperature and humidity at $22{\pm}2^{\circ}C$ and 40~60 %, respectively. The voltage of the battery used for the tests was measured to be 4.18V between positive pole (+) and negative pole (-)(1), and 4.19 V between positive pole (+) and negative pole (-)(2). This study applied the Korean Industrial Standard (KS) to the flammability test of cellular phones due to a general flame applied to them and found that no damage occurred to the built-in battery even though the flame was applied to the cases of cellular phones for 30 seconds. From the results of immersing the cellular phones in the saline solution (NaCl, 0.9 %) for 180 seconds, it was found that there was a trace of carbonization and melting due to the heat caused by leaking current. It can be seen that when the cellular phones were heated for 70 seconds using a microwave oven (MWO), the areas containing the metal holder, recharging connector, antenna, etc., were melted and discolored and that other areas showed no particular problems. That is, while the external carbonization of cellular phones, built-in metals and dielectric materials, and damage and deformation of the battery terminal block, etc., occurred differently depending on the types of energy sources, the voltage showed comparatively constant characteristics. Therefore, it is thought to be possible to attribute the cause of damage to the battery by performing analysis taking into consideration comprehensively the characteristics of the flame spread pattern as well as the melting and deformation of metals.

Electrode characteristics of $AB_2$ type hydrogen storage alloy modified by Cr, La addition and fluorination ($AB_2$계 수소저장합금의 전극특성에 미치는 Cr, La 첨가 효과 및 표면 불화처리 효과)

  • Chang I.;Lee B. H.;Cho W. I.;Jang H.;Cho B. W.;Yun K. S.
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.45-51
    • /
    • 1998
  • [ $AB_2-type$ ] alloy, one kind of hydrogen storage alloys used as an anode of Ni-MH batteries, has large discharge capacity but has remaining problems regarding initial activation, cycle life and self-discharge. This study investigates the effects of Cr-addition and fluorination after La-addition on $Zr_{0.7}Ti_{0.3}V_{0.4}Mn_{0.4}Ni_{1.2}$, composition $AB_2-type$ alloy. EPMA and SEM surface analysis techniques were used and the crystal structure was characterized by XRD analysis. In addition, electrodes were fabricated out of the alloys and characterized by constant current cycling test, electrochemical impedance spectroscopy and potentiodynamic polarization. Cr-addition was found to be effective to cycle life and self-discharge but ineffective to initial activation due to formation of stable oxide film on surface. Fluorination after La-addition to the alloys improved initial activation remarkably due to formation of highly reactive particles on surface.

Analysis on Targeting Countries for Overseas Expansion of Korean Companies: Focusing on The Difference between Shipping, Manufacturing and Logistics Companies (우리나라 기업의 해외진출 대상 국가에 관한 연구: 제조·물류 기업별 차이를 중심으로)

  • Kim, Sang Youl;Park, Ho;Jang, Hyunmi;Kim, Taehun
    • Journal of the Korean Data Analysis Society
    • /
    • v.20 no.6
    • /
    • pp.3087-3099
    • /
    • 2018
  • Due to the constant changes of companies' global networks, the expansion of global e-commerce as well as the market-oriented global supply chain management, global enterprises are strategically selecting and entering into viable countries able to become global footholds. Therefore, this study aims to scrutinize the trend of changes in the global networks of Korean companies by analyzing the current overseas countries over the past decade. From the analysis, it has been found that there is a significant difference in the priorities of targeting countries among shipping, manufacturing and logistics companies. Logistics companies preferred to enter Germany first while they attached to a lower priority to Singapore. Manufacturing companies had a lower priority to advance to India, while they preferred to advance to Mexico; however, shipping companies were analyzed to prefer to enter the US. In addition, all of these companies identified the importance of securing volume and network by entering overseas markets to achieve economies of scale and scope and to maintain global competitiveness. Joint overseas expansion of manufacturers with shipping and logistics companies can be recommended to facilitate the entry and thus, enhance global competitiveness and service capabilities and also secure new growth engines.

Characteristics of the ( Pb, La ) $TiO_3$ Thin Films with Pb/La Compositions (Pb/La 조성에 따른 ( Pb, La ) $TiO_3$ 박막의 특성 변화)

  • Kang, Seong-Jun;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.29-37
    • /
    • 1999
  • In this study, we have prepared PLT thin films having various La concentrations by using sol-gel method and studied on the effect of La concentration on the electrical properties of PLT thin films. As the La concentration increases from 5mol% to 28mol%, the dielectric constant at 10kHz increases from 428 to 761, while the loss tangent decreases from 0.063 to 0.024. Also, the leakage current density at 150kV/cm has a tendency to decrease from 6.96${\mu}A/cm^2$ to 0.79${\mu}A/cm^2$. In the result of hysteresis loops of PLT thin films, the remanent polariation and the coercive field decrease from 9.55${\mu}C/cm^2$ to 1.10${\mu}C/cm^2$ and from 46.4kV/cm to 13.7kV/cm, respectively. With the result of the fatigue test on the PLT thin films, we have found that the fatigue properties are improved remarkably as the La concentration increases from 5 mol% to 28mol%. In particular, the PLT28) has paraelectric phase and its charge storage clensity and leakage current density at 5V are 134fC/${\mu}cm^2$ and 1.01${\mu}A/cm^2$, respectively. The remanent polarization and coercive field of the PLT(10) film are 6.96${\mu}C/cm^2$ and 40.2kV/cm, respectively. After applying of $10^9$ square pulses with ${\pm}5V$, the remanent polarilzation of the PLT(10) film decreases about 20% from the initial state. In the results, we conclude that the 10mol% and the 28mol% La doped PLT thin films are very suitable for the capacitor dielectrics of new generation of DRAM and NVFRAM respecitively.

  • PDF

MICROLEAKAGE AND WATER STABILITY OF RESIN CEMENTS

  • Choi Sun-Young;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.369-378
    • /
    • 2003
  • Statement of Problem: Recently, resin cements have become more widely used and have been accepted as prominent luting cements. Current resin cements exhibit less microleakage than conventional luting cements. However, the constant contact with water and exposure to occlusal forces increase microleakage even in resin cements inevitably. Most bonding resins have been modified to contain a hydrophilic resin such as 2-hydroxyethylmethacrylate (HEMA) to overcome some of the problems associated with the hydrophobic nature of bonding resins. By virtue of these modifications, bonding resins absorb a significant amount of water, and there may also be significant stresses at bonding interfaces, which may adversely affect the longevity of restorations. Therefore the reinforcement of water stability of resin cement is indispensable in future study. Purpose: This study was conducted to examine the influence of water retention on microleakage of two resin cements over the period of 6 months. Materials and Methods: 32 extracted human teeth were used to test the microleakage of a single full veneer crown. Two resin cements with different components and adhesive properties - Panavia F (Kuraray Co., Osaka, Japan) and Super-Bond C&B (Sun Medical Co., Kyoto, Japan)- were investigated. The storage medium was the physiological saline solution changed every week for 1 month, 3 months, and 6 months. One group was tested after storage for 1 day. At the end of the each storage period, all specimens were exposed to thermocycling from $5^{\circ}C$ to $55^{\circ}C$ of 500 cycles and chewing simulation of 50,000 cycles, and then stained with 50% silver nitrate solution. The linear penetration of microleakage was measured using a stereoscopic microscope at ${\times}40$ magnification and a digital traveling micrometer with an accuracy of ${\pm}3{\mu}m$. Values were analyzed using two-way ANOVA test, Duncan's multiple range tests (DMRT). Results : Statistically significant difference of microleakage was shown in the 3-month group compared with the1-day or 1-month group in both systems (p<0.05) and there were statistically significant differences in microleakage between the 3-month group and the 6-month group in both systems (p<0.05). The two systems showed different tendency in the course of increased microleakage during 3 months. In Panavia F, microleakage increased slowly throughout the periods. In Super-Bond C&B, there was no significant increase of microleakage for 1 month, but there was statistically significant increase of microleakage for the next 2 months. For the mean microleakage for each period, in the 3-month group, microleakage of Super-Bond C&B was significantly greater than that of Panavia F. On the other hand, in the 6-month group, microleakage of Panavia F was significantly greater than that of Super-Bond C&B (p<0.05). Conclusion: Within the limitation of this study, water retention of two different bonding systems influence microleakage of resin cements. Further studies with the longer observation periods in viro are required in order to investigate water stability and the bonding durability of the resin cement. CLINICAL IMPLICATIONS Microleakage at the Cement-tooth interfaces did not necessarily result in the failure of the crowns. But it is considered to be a major factor influening the longerity of restorations. Further clinical approaches for decreasing the amount of microleakage are required.

Characteristics of Titanium Dioxide-Impregnated Fibrous Activated Carbon and Its Application for Odorous Pollutant (이산화티타늄 담지 섬유형 활성탄소의 특성 및 악취오염물질 제어를 위한 응용)

  • Jo, Wan-Kuen;Hwang, Eun-Song;Yang, Sung-Bong
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • The application of fibrous activated carbon (FAC)-titanium dioxide ($TiO_2$) hybrid system has not been reported yet for the control of malodorous dimethyl sulfide (DMS) at residential environmental levels. Accordingly, the current study was designed not only to characterize this hybrid system using x-ray diffraction method, particulate surface measurement and Fourier transform Infrared (FTIR) method, but also to evaluate its adsorptional photocatalytic activity (APA) for the DMS removal. The physical/surface characteristics of FAC-$TiO_2$ which was prepared in this study suggested that the hybrid material might have certain APA for DMS. The Brunauer-Emmett-Teller (BET) specific area, total pore volume, micropore volume and mesopore volume decreased all as the $TiO_2$ amounts coated on FAC increased, whereas the reverse was true for average pore diameter. $TiO_2$ coated onto FAC did not influence the adsorptional activity of FAC for the DMS input concentration of 0.5 ppm. The APA test of the hybrid material presented that the initial removal efficiencies of DMS were 93, 78, 71 and 57% for the flow rates of 0.5, 1.0, l.5 and 2.0 L/min, respectively, and they decreased somewhat 2 h after the experiment started and kept almost constant for the rest experimental period. Under this pseudo-equilibrium condition, the DMS removal efficiencies were 78, 58, 53 and 36% for the four flow rates, respectively. Meanwhile, there were no significant byproducts observed on the surfaces of the hybrid material. Consequently, this study suggests that, under the experimental conditions used in the present study, the hybrid material can be applied for DMS at residential environment levels without being interfered by any byproducts.