• 제목/요약/키워드: Conservative measure

검색결과 204건 처리시간 0.025초

불확실한 선형시스템 고유값 배치의 비대칭 강인한계 (Asymmetric Robustness Bounds of Eigenvalue Distribution for Uncertain Linear Systems)

  • 이재천
    • 제어로봇시스템학회논문지
    • /
    • 제5권7호
    • /
    • pp.794-799
    • /
    • 1999
  • This study deals with robustness bounds estimation for uncertain linear systems with structured perturbations where the eigenvalues of the perturbed systems are guaranteed to stay in a prescribed region. Based upon the Lyapunov approach, new theorems to estimate allowable perturbation parameter bounds are derived. The theorems are referred to as the zero-order or first-order asymmetric robustness measure depending on the order of the P matrix in the sense of Taylor series expansion of perturbed Lyapunov equation. It is proven that Gao's theorem for the estimation of stability robustness bounds is a special case of proposed zero-order asymmetric robustness measure for eigenvalue assignment. Robustness bounds of perturbed parameters measured by the proposed techniques are asymmetric around the origin and less conservative than those of conventional methods. Numerical examples are given to illustrate proposed methods.

  • PDF

A newly-designed method to measure liner polymerization shrinkage

  • Ikejima, Iwao;Matsuzawa, Norihiko;Momol, Yasko;Kohno, Atsushi
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.604-604
    • /
    • 2003
  • I. Objectives Newly-designed method was evaluated to measure the linear polymerization shrinkage of light-cured resin composites. II. Materials and Methods A resin composite(Clearfil AP-X, Kuraray, Japan) was filled into a vinyl-polysiloxan mold(1 to 8mm-depth, and 7mm-diameter). As indicators, 4 beads(Retention Beads 2 SS, GC, Japan;particle size $200{\;}\mu\textrm{m}$) were placed diagonally on the resin surface of a mold. The coordinates (x, y, z, pasition) of each indicator were measrued by a measuring-microscope after which the resin surface was irradiated by a curing-light source(Optilux 500, Demetron/Kerr, USA) for 40 sec. After 20 sec the coordinates were again measured.(omitted)

  • PDF

복합레진 수복시 와동의 크기 및 수복 방법이 교두 굴곡에 미치는 영향 (INFLUENCE OF CAVITY SIZE AND RESTORATION METHODS ON THE CUSP DEFLECTION IN COMPOSITE RESTORATION)

  • 이미라;이인복;석창인;이상탁;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.532-540
    • /
    • 2004
  • The aim of this study was to measure the cusp deflection during composite restoration for MOD cavity in premolar and to examine the influence of cavity dimension, C-factor and restoration method on the cusp deflection. Thirty extracted maxillary premolar were prepared to four different sizes of MOD cavity and divided into six groups. The width and depth of the cavity were as follows. Group 1; $1.5{\;}{\times}{\;}1{\;}mm$, Group 2; $1.5{\;}{\times}{\;}2{\;}mm$, Group 3; $3{\;}{\times}{\;}1{\;}mm$, and Group 4-6; $3{\;}{\times}{\;}2{\;}mm$ respectively. Group 1-4 were restored using bulk filling method with Z-250 composite. However, Group 5 was restored incrementally, and Group 6 was restored with an indirect resin inlay. The cusp deflection was recorded at the buccal and lingual cusp tips using LVDT probe for 10,000 seconds. The measured cusp deflections were compared between groups, and the relationship between the cube of the length of cavity wall/the cube of the thickness of cavity wall ($L^3/T^3$). C-factor and cusp deflection or % flexure ($100{\;}{\times}$ cuspal deflection / cavity width) was analyzed. The cusp deflection of Group 1-4 were $12.1{\;}\mu\textrm{m},{\;}17.2{\;}\mu\textrm{m},{\;}16.2{\;}\mu\textrm{m}{\;}and{\;}26.4{\;}\mu\textrm{m}$ respectively. The C-factor was related to the % flexure rather than the cusp deflection. There was a strong positive correlationship between the $L^3/T^3$ and the cusp deflection. The cusp deflection of Group 5 and 6 were $17.4{\;}\mu\textrm{m}{\;}and{\;}17.9{\;}\mu\textrm{m}$ respectively, which are much lower value than that of Group 4.

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

막대를 이용한 목 안정화 운동이 만성 목 통증 환자의 목 통증, 두통 및 삶의 질에 미치는 영향 (Effects of Neck Stabilization Exercise Using a Stick on Neck Pain, Headache and Quality of Life in Patients with Chronic Neck Pain)

  • 장혜진;이상덕
    • 대한통합의학회지
    • /
    • 제12권3호
    • /
    • pp.121-130
    • /
    • 2024
  • Purpose : This study was conducted to investigate the effect of neck stabilization exercises using a stick on the pain, headache, and quality of life of adult patients with chronic non-specific neck pain. Methods : The participants of this study were 28 adult patients with chronic non-specific neck pain. The subjects were assigned to the experimental group (n=15, neck stabilization exercises using a stick after conservative physical therapy) and the control group (n=13, conservative physical therapy) according to the order of participation in the study and the intervention methods. The intervention was conducted three times a week for four weeks. The neck stabilization exercises using a stick consisted of isometric exercises of the muscles around the neck and strengthening exercises of the muscles around the scapula. The visual analog scale (VAS) and headache impact test (HIT-6) were used to measure the pain and headache, and the SF 36 health questionnaire (SF-36) was used to measure the quality of life. Results : In the comparison of VAS, HIT-6, and SF-36, there were significant differences between before and after the intervention in both the experimental and control groups (p<.05). The pre-post comparisons between the two groups according to the experiment showed significant differences between the experimental group and the control group (p=.001). However, the experimental group showed greater changes than the control group. Conclusion : Through this study, it was confirmed that neck stabilization exercises using a stick have positive effects on reducing the neck pain and headaches and improving the quality of life of adult patients with chronic neck pain. Therefore, it is considered that neck stabilization exercises using a stick can be used as an effective exercise method for the treatment and prevention of patients with chronic neck pain in the future.

산부식처리(酸腐蝕處理) 치아법랑질(齒牙琺瑯質) 표면(表面)의 조도(粗度)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMFNENTAL STUDY ON THE SURFACE ROUGHNESS OF ACID ETCHING ENAMEL SURFACE IN HUMAN TEETH)

  • 이은구
    • Restorative Dentistry and Endodontics
    • /
    • 제5권1호
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to measure the roughness on the acid -etching surface. The etching agents of three-kinds composite resins were used to etch the tooth surface. Newly extracted I5-anterior teeth were invested with self-curing acrylic resin, and the labial surface was exposed. The exposed labial side was polished with abrasive papers and finally polished on polishing machine with zinc oxide powder. After the teeth were polished, the specimens were washed by water and dried by air. Surface roughness tester, Taylor-Habson's Taly Surf-10, (Fig-1) was used to measure roughness of this unetched tooth surface. And that, the specimens were divided into three groups. The first group was etched with Restodent etchant, the second group was etched with Nuva-system etchant, and Hi-pol etching agent was used in the third group. And the surface roughness tester was used to measure roughness of the etching teeth surface. The results obtained were as follows. 1. The roughness of acid-etched enamel were increased $2{\mu}m$ to $6{\mu}m$. 2. Hi-pol etchant produced the smoothest surface($2.3{\mu}m$). 3. Restodent etchant($3.8{\mu}m$) and Nuva-system etchant($3.7{\mu}m$) produced rougher surface than Hi-pol.

  • PDF

Effects of Pilates and Tai Chi on Pain and Dysfunction in Chronic Lumbago Patients

  • Choi, Jung Hyun;Hwang, Hyun Sook
    • 국제물리치료학회지
    • /
    • 제7권1호
    • /
    • pp.933-937
    • /
    • 2016
  • The purpose of this study was to identify the effects of Pilates and Tai Chi as physical therapy interventions for pain and dysfunction in chronic lumbago patients. A total of 31 females who were at least 20 years old and diagnosed with chronic lumbago were divided into a Pilates group(PG) (n=10), Tai Chi group(TCG)(n=11), and conservative group(CG)(n=10), to measure their pain and dysfunction before and after a six week intervention. With regard to the changes in the lumbago consciousness scale before and after the six-week intervention, all three groups showed statistical significance(p<.05). The intergroup differences were significant between the PG and CG and between the TCG and CG. All three groups also showed statistical significance(p<.05) in the Oswestry Disability Index before and after the six-week intervention. Again, the intergroup differences were significant between the PG and CG and between the TCG and CG. Based on these results, the application of Pilates and Tai Chi with conservative treatment may be effective in reducing pain and improving dysfunction in chronic lumbago patients.

쥐의 치수자극에 의해 유발되는 자율신경 반응과 악안면 근육활동의 변화 (CHANGES IN AUTONOMIC RESPONSES AND JAW MUSCLE ACTIVITY INDUCED BY TOOTH PULP STIMULATION IN THE RAT)

  • 유미경;박수정
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.657-665
    • /
    • 1999
  • The effects of application of mustard oil (MO), a small-fiber excitant and inflammatory irritant into the rat maxillary molar tooth pulp on arterial blood pressure and heat race, and electromyographic (EMG) activity of the jaw muscles were assessed in the anesthetized rats. In addition, Evans blue extravasation following pulpal MO application was measured. Application of MO into the tooth pulp produced a significant increase in mean arterial pressure and heat rate which gradually returned to baseline level. Application of MO into the tooth pulp induced a significant and short-lasting increase in EMG activity of digastric masseter and tongue muscle. Application of MO into the tooth pulp significantly increased the plasma extravasation of Evans blue dye. However, Application of mineral oil into the tooth pulp did not produce any significant changes in EMG activity of the digastric, masseter and tongue muscles, mean arterial pressure and heart rate, and plasma extravasation of Evans blue dye. These findings indicate that changes in arterial blood pressure, heart rate, jaw muscle activity and plasma extravasation accompanying noxious tooth pulp stimulation call be utilized as indirect measure of orofacial pain and inflammation.

  • PDF

Experimental investigation of inelastic buckling of built-up steel columns

  • Hawileh, Rami A.;Abed, Farid;Abu-Obeidah, Adi S.;Abdalla, Jamal A.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.295-308
    • /
    • 2012
  • This paper experimentally investigated the buckling capacity of built-up steel columns mainly, Cruciform Columns (CC) and Side-to-Side (SS) columns fabricated from two Universal Beam (UB) sections. A series of nine experimental tests comprised of three UB sections, three CC sections and three SS sections with different lengths were tested to failure to measure the ultimate axial capacity of each column section. The lengths used for each category of columns were 1.8, 2.0, and 2.2 m with slenderness ratios ranging from 39-105. The measured buckling loads of the tested specimens were compared with the predicted ultimate axial capacity using Eurocode 3, AISC LRFD, and BS 5959-1. It was observed that the failure modes of the specimens included flexural buckling, local buckling and flexural-torsional buckling. The results showed that the ultimate axial capacity of the tested cruciform and side-by-side columns were higher than the code predicted design values by up to 20%, with AISC LRFD design values being the least conservative and the Eurocode 3 design values being the most conservative. This study has concluded that cruciform column and side-to-side welded flange columns using universal beam sections are efficient built-up sections that have larger ultimate axial load capacity, larger stiffness with saving in the weight of steel used compared to its equivalent universal beam counterpart.

실배관 파괴특성 평가에 관한 연구 (A Study on the Evaluation of the Pipe Fracture Characteristic)

  • 박재실;김영진;석창성
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.107-114
    • /
    • 2005
  • In order to analyze the elastic-plastic fracture behavior of a structure, the fracture resistance curve of the material should be known first. The standard CT specimen was used to obtain the fracture resistance curves of a piping system. However, it is known that the fracture resistance curve by the standard CT specimen is very conservative to evaluate the integrity of a structure. Also the fracture resistance curve is effected by the specimen geometry and the dimensions because of the constraint effect. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the standard CT specimen and to provide an additional safety margin. For these, the fracture tests using a real pipe specimen and the standard CT specimen test were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method was used to measure the crack extension and the length for the pipe test. Also finite element analyses were performed with a CT specimen and a pipe in order to prove the additional safety margin. From the result of tests and analyses of the pipe and the standard CT specimen, it was observed that the fracture analysis with the standard CT specimen is conservative and the additional safety margin was proved.