• 제목/요약/키워드: Conservative Wave

검색결과 116건 처리시간 0.025초

잠수물체에 의하여 발생되는 비선형파의 수치 시뮬레이션 (Numerical Simulations of Nonlinear Waves Generated by Submerged Bodies)

  • 강국진
    • 한국전산유체공학회지
    • /
    • 제2권1호
    • /
    • pp.13-20
    • /
    • 1997
  • A fundamental study for the numerical scheme to simulate unsteady nonlinear waves by solving Euler equations is presented. First a conservation form and a non-conservation form of the Euler equations with a free surface fitted coordinate system are compared. Next, a time splitting fractional step method and an alternating direction implicit(ADI) method for the time integration are compared. For the comparative study, flow calculations around a bottom bump in a channel and a NACA 0012 hydrofoil in a flume are performed. The results show that the ADI method with a third order upwind differencing scheme is very efficient in reducing the computing time with keeping the accuracy, And, there is no distinct difference between two expression forms except that the non-conservative form shows faster wave propagating velocity than the conservation form. Some results are compared with experiments and show good agreement.

  • PDF

준 3차원적 연안류 모형 (Quasi-3D Wave-Induced Circulation Model)

  • Lee, Jung-Lyul
    • 한국해안해양공학회지
    • /
    • 제6권4호
    • /
    • pp.459-471
    • /
    • 1994
  • 쇄파작용에 기인한 준 3차원적 연안류 순환 모델의 수치 기법을 제시한다. 지배 방정식은 근사 factorization 기법과 fractional step method를 사용하여 음해법으로 수치해석 되었고 분할된 식은 유한 체적법으로 차분된다. 계산된 3차원적 연안류 패턴의 한 예로서 Gourlay(1974)의 실험자료와 비교하여 간접적으로 모델의 타당성을 검증한다.

  • PDF

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석 (Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device)

  • 김동영;이상석;현석산;이진규
    • 한국자기학회지
    • /
    • 제24권5호
    • /
    • pp.146-151
    • /
    • 2014
  • 영구자석과 홀소자로 구비된 집게형 맥진기를 이용하여 목 부위의 경추동맥의 맥진파형과 손목 부위의 요골동맥 맥진파형을 각각 측정하였다. 두 개의 맥진파형을 비교하여 얻은 맥파전달시간과 맥파전달속도를 분석하였다. 맥파전달속도는 기존의 방식으로 측정한 값과 유사한 약 8.5 m/s으로 나타났다. 재현성과 신뢰성이 있는 한방의료기기인 집게형 맥진기로 얻은 맥파전달속도를 기준하여 동맥경화도를 예측할 수 있음을 제시하였다.

Outcomes of the GentleWave system on root canal treatment: a narrative review

  • Hernan Coaguila-Llerena;Eduarda Gaeta;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.11.1-11.11
    • /
    • 2022
  • This study aimed to describe the outcomes of the GentleWave system (GW) (Sonendo) on root canal treatment. Published articles were collected from scientific databases (MEDLINE/PubMed platform, Web of Science, Scopus, Science Direct and Embase). A total of 24 studies were collected from August/2014 to July/2021, 20 in vitro and 4 clinical. GW System was not associated with extrusion of the irrigant, promoted faster organic dissolution than conventional syringe irrigation (CSI), passive ultrasonic irrigation (PUI) continuous ultrasonic irrigation (CUI) and EndoVac, reduced more bacterial DNA and biofilm than PUI and CUI, promoted higher penetration of sodium hypochlorite into dentinal tubules than PUI and CUI in vitro, and removed more intracanal medication than CSI and PUI. GW was able to remove pulp tissue and calcifications. Moreover, its ability to remove hard-tissue debris and smear layer was better than that of CSI, and its ability to remove root canal obturation residues was lower or similar to that of PUI, and similar to that of CSI and EndoVac. Regarding root canal obturation of minimally instrumented molar canals, GW was associated with high-quality obturation. Clinically, the success rate of endodontic treatment using GW was 97.3%, and the short-term postoperative pain in the GW group was not different from CSI. Further research, mainly clinical, is needed to establish whether GW has any advantages over other available irrigation methods.

Influence of operator's experience level on lifespan of the WaveOne Primary file in extracted teeth

  • Saleh, Abdulrahman Mohammed;Tavanafar, Saeid;Vakili-Gilani, Pouyan;Al Sammerraie, Noor Jamal;Rashid, Faahim
    • Restorative Dentistry and Endodontics
    • /
    • 제38권4호
    • /
    • pp.222-226
    • /
    • 2013
  • Objectives: The aim of this study was to assess the influence of operator experience level on the lifespan of the WaveOne Primary file (Dentsply Maillefer, Ballaigues, Switzerland) in extracted teeth. Materials and Methods: Moderately curved canals of extracted maxillary and mandibular molars were randomly distributed into 2 groups: experienced and inexperienced operators. Ten files were allocated to each group (n = 10). Each canal was prepared until the working length was reached, and the same file was used to prepare additional canals until it separated. The number of canals prepared before file separation was recorded. The fragment length of each file was measured, and the location of the fragment in the canal was determined. Data were statistically analysed using the independent 2-sample t-test. Results: The 2 operators prepared a total of 324 moderately curved canals of maxillary and mandibular molars. There was no significant intergroup difference in the mean number of canals prepared (p = 0.27). The average lifespan of the WaveOne Primary file was 17.1 and 15.3 canals, and the longest lifespan was 25 and 20 canals, when used by experienced and inexperienced operators, respectively. There were no statistically significant intergroup differences in separated fragment length and location. Conclusions: Within the limitations of this study, operator experience level appears to have no effect on the lifespan of the WaveOne Primary file in preparation of moderately curved canals. Single teeth with multiple canals can be prepared safely even by a novice operator by using a single file.

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Tatiana Dias Costa;Elison da Fonseca e Silva;Paula Liparini Caetano ;Marcio Jose da Silva Campos ;Leandro Marques Resende ;Andre Guimaraes Machado;Antonio Marcio Resende do, Carmo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.6.1-6.10
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.

동 및 철이온이 MMA/TBBO레진의 상아질 접착에 미치는 영향 (EFFECT OF CUPRIC AND FERRIC IONS ON BONDING OF MMA/TBBO RESIN TO DENTIN)

  • 박진훈
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.423-430
    • /
    • 1993
  • The purpose of this study was to investigate the effect of ferric and ferric ions contained in phosphoric acid solution as a pretreatment solution on bonding of MMA/TBBO resin to dentin. Each of 1 % and 3 % ferric chloride. cupric chloride. cupric sulfate. and cupric nitrate was mixed into 10% phosphoric acid solution and pretreated dentin surface of bovine anterior teeth for 30 seconds followed- by water rinse and dry. Tensile bond strength was determined after bonding of pretreated dentin with MMA/TBBO resin by use of brush-on ;technique and storing for 24 hours in 3it distilled water. The amount of cupric ions adsorbed on pretreated dentin surface was detected by Wave-Dispersion X-ray microanalyzer for different groups of each pretreatment solution containing cupric salts. The pretreatment with cupric ions contained in 10% phosphoric acid solution was effective to increase bonding strength of MMA/TBBO resin to dentin but not in case of ferric ions. The pretreatment with 3 % cupric chloride and cupric nitrate both enhanced significant increase in bonding strength compared to the control group of 10% phosphoric acid solution(p<0.05). Cupric ions measured in pretreated dentin surface was higher in 3 % cupric chloride group than in 1% cupric chloride group, but couldn't find distinct relationship from the results of this experiment between the amount of adsorbed cupric ions according to the kind of cupric salts and the bonding strength value.

  • PDF

Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구 (Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study)

  • 김현철;곽상원;하정홍
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.