• Title/Summary/Keyword: Connector design

Search Result 263, Processing Time 0.024 seconds

The question at issue of connector wire in High Speed Railway Catenary System of France (프랑스 고속철도 전차선로 시스템에서 균압선의 문제점)

  • 안영훈
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.636-651
    • /
    • 2000
  • In these days, SNCF replace the connector wire (M-T type) with a dropper has a equivalent role and function of the one in general lines of TGV, and change the connector wire (T-T-M-M-T-T, T-T-M-M-T type, etc) into a New one has more flexible cable in parallel lines (air section air joint, etc) of TGV. The Connector wire has many problems according to a flow of excessive circulation current (or traction current) and a sudden rise of temperature on catenary when electric locomotive is running in high speed. To solve the question at issue of the connector wire in high speed railway catenary system of Fiance, SNCF return their operating experience in TGV lines to design and execution of catenary system Therefore, we have to deal with the question in design and execution of catenary system for kyoungbu HSR line because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

Design of Fuse Mounted Elbow Connector (퓨즈가 내장된 엘보접속재의 설계)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

A Study on the Evaluation of Shear Resisting Capacity for the Various Perforated Shape Shear Connector (합성거동을 위한 유공판형 전단연결재의 강도평가에 관한 연구)

  • Kim, Young-Ho
    • Composites Research
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2008
  • In recent years, the reversed L-shaped perforated shear connector has been developed to mitigate the problem associated with headed stud and Perforbond shear connector and to simulate the simultaneous failure of concrete and shear connector. And FRP perforated shear connector has been applied to composite concrete and FRP module in the FRP-concrete composite bridge deck. The design criterion of the reversed L-shaped and FRP perforated shear connector has not been established yet since the lack of experimental and analytical study results. In this paper, the existing design equations for the Perforated were briefly discussed and the equation fur the prediction of shear resisting capacity of the reversed L-shaped and FRP perforated shear connector was suggested based on the experimental test, FEM analysis. and the existing equation for the Perfobond. The predict results obtained by the suggested equation arc compared with the experimental results, the applicability and effectiveness of suggested equation was verified.

Energy dissipation of steel-polymer composite beam-column connector

  • Wang, Yun-Che;Ko, Chih-Chin
    • Steel and Composite Structures
    • /
    • v.18 no.5
    • /
    • pp.1161-1176
    • /
    • 2015
  • The connection between a column and a beam is of particular importance to ensure the safety of civil engineering structures, such as high-rise buildings and bridges. While the connector must bear sufficient force for load transmission, increase of its ductility, toughness and damping may greatly enhance the overall safety of the structures. In this work, a composite beam-column connector is proposed and analyzed with the finite element method, including effects of elasticity, linear viscoelasticity, plasticity, as well as geometric nonlinearity. The composite connector consists of three parts: (1) soft steel; (2) polymer; and (3) conventional steel to be connected to beam and column. It is found that even in the linear range, the energy dissipation capacity of the composite connector is largely enhanced by the polymer material. Since the soft steel exhibits low yield stress and high ductility, hence under large deformation the soft steel has the plastic deformation to give rise to unique energy dissipation. With suitable geometric design, the connector may be tuned to exhibit different strengths and energy dissipation capabilities for real-world applications.

FRACTURE STRENGTH BETWEEN DIFFERENT CONNECTOR DESIGNS OF ZIRCONIA CORE FOR POSTERIOR FIXED PARTIAL DENTURES MANUFACTURED WITH CAD/CAM SYSTEM (CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도)

  • Seo Jun-Yong;Park In-Nim;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.29-39
    • /
    • 2006
  • Statements of problem: Zirconia core is used for posterior fixed partial dentures because it's good mechanical properties. Stress is concentrated on connectors in fixed partial dentures, so the proper design of connector areas is needed for adequate mechanical long-term properties of any prosthesis. The area of connector is critical, but tooth size and surrounding soft tissue limit the connector design. Purpose: The purpose of this study is to compare fracture strengths between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system and determining the optimal connector design satisfying strength and hygiene. Material and method: The following four groups of 40 posterior fixed partial denture specimens(each group 10) were fabricated as followed; group 1 vertical height of connector is 3mm (control group, all groups have the same condition); group 2, lingual vertical 1mm reinforcement on connector; group 3, lingual vertical 2mm reinforcing on connector and group 4, lingual vertical 3mm reinforcing on connector. Specimens were subjected to compressive loading on the central fossa of pontic by instron. SEM was used to identify the initial crack and characterize the fracture mode. Results: The results were as follows: 1. The mean fracture load of the non-lingual reinforcing group was 1212N and the lingual vertical 1mm reinforcing group was 1510N, the lingual vertical 2mm reinforcing group was 1882N, the lingual vertical 3mm reinforcing group was 1980N. 2. The reinforcing groups were statistically significant compared to non-reinforcing groups(P<0.001). 3. There were 2, 3mm reinforcing groups that were statistically significant compared to 1mm reinforcing groups(P<0.001), and the 3mm reinforcing group was not statistically significant compared to 2mm reinforcing groups(P>0.05) 4. Fractures were initiated in gingival embrasures of connectors and processed to the loading site. Conclusion: In this study, lingual reinforcement of connector for improved strength of zirconia based fixed partial denture is nessasary. And long-term study for clinical application is required

Improvement of Connector Performance Using Analysis of Characteristic Impedance (특성임피던스 분석을 사용한 커넥터 성능향상)

  • Yang, Jeong-Kyu;Kim, Moon-Jung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.9
    • /
    • pp.47-53
    • /
    • 2011
  • The signal transmission properties of the connector such as insertion loss and return loss are investigated using analysis procedure of S-parameter simulation, equivalent model extraction, and characteristic impedance calculation. S-parameter simulation is performed by connector's modeling and solving based on 3-dimensional finite element method. The connector's equivalent model of ${\pi}$ type is are proposed and extracted with an optimization process of circuit analysis simulator. The characteristic impedance of the connector is calculated with results of circuit analysis simulation and S-parameter data. According to the connector's characteristic impedance, it's revised design is carried out. In this work, the connector's effective contact area is increased and its body is applied as a high dielectric material in order to increase its capacitance and then obtain impedance matching. Therefore, return loss of the connector is improved by approximately 10 dB due to its design revision.

A Study on the Design of High-Voltage Connector for Green Car using FEM (유한요소법을 이용한 친환경 자동차용 고전압 커넥터 설계에 관한 연구)

  • Kim, Sung-Woong;Choi, Jung-Wook;Kim, Hyeung-Rak;Kwon, Young-Seok;Kang, Nam-Jin;Choi, Kyung-Seok;Park, Hyung-Pil;Cha, Baeg-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.716-723
    • /
    • 2011
  • The battery capacity of electric/hybrid vehicle is much larger than present automobile. For that reason, the connector of Green Car should be designed to transmit the high-electric voltage. In addition, the electromagnetic wave should be shielded to protect communication and signal circuits. In this study, shielding performance of the connector was analyzed through electromagnetic shield analysis, and a connector of Green Car was designed using thermoelectrical analysis, which is capable of transmitting the high-electric power. In the design of connector structure, the improved stability and workability was considered.

Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors (ㄱ형 Perfobond 리브 전단연결재의 적용성 평가)

  • Lee, Heung-Su;Chung, Chul-Hun;Kim, Byung-Suk;Kang, Jae-Yoon;Sohn, You-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

The Separation Behaviors from Assemble Conditions for Pitch 1.25mm Level Wire to Board Connector (피치 1.25mm 급 Wire to Board Connector 에서 조립상태로부터 분리거동에 관한 연구)

  • Heo, Young-Moo;Yoon, Gil-Sang
    • Design & Manufacturing
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • In this study, the modification structure design of insulation displacement connector developed was considered for simplification of assembly process. The modified connector consisted terminal, wafer and fitting nails. The separation behavior under locking condition for pitch 1.25mm wire to board connector was measured and the apparatus for the test was made. The maximum restraining force was measured about 4.5kgf that was bigger value than the specification limit. And the pulling force of a wire was also indicated about 2.3kgf.