• 제목/요약/키워드: Connection behavior

검색결과 1,125건 처리시간 0.031초

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

직각판형 외다이아프램 각형강관기둥-H형강보 접합부의 방강접거동에 관한 해석적연구 (A Numerical Study on the Semi-Rigid Behavior of Steel Tubular Column to H Beam Connection with Exterior Square-Plate Diaphragms)

  • 채용수;최성모;김동규
    • 한국강구조학회 논문집
    • /
    • 제13권3호
    • /
    • pp.289-299
    • /
    • 2001
  • 본 논문은 직각펀형 외다이아프램 형식의 각형강관-H형강보 접합부의 반강접 특성을 파악하기 위하여 기존 실험결과를 수집하여 모든 실험체를 기준이 되는 실험방법과 동일하게 모델링하여 유한요소해석을 실시하였다. 이 해석결과를 실험결과와 비교 검증하여 해석결과의 신뢰성을확보, 이를 준용하는 것으로 하여 본 접합부형식의 반강접거동에 영향을 미치는 주요한 변수를 파악하고 차후 골조해석에 적용 가능한 적절한 모멘트-회전각 곡선을 제안, 함수를 구성하는 세가지 파라메타에 대하여 다중선형회귀분석을 실사하였다.

  • PDF

Research on the mechanical properties of membrane connections in tensioned membrane structures

  • Zhang, Yingying;Zhang, Qilin;Li, Yang;Chen, Lu
    • Structural Engineering and Mechanics
    • /
    • 제49권6호
    • /
    • pp.745-762
    • /
    • 2014
  • As an important part, the connections generally are important for the overall behavior of the structure and the strength and serviceability of the connection should be ensured. This paper presents the mechanical properties of membrane connections in tensioned membrane structure. First, the details of common connections used in the membrane structure are introduced. Then, the common connections including membrane seam, membrane-flexible edge connection and membrane-rigid edge connection are tested and the corresponding failure mechanisms are discussed. Finally, the effects of connection parameters on the connection strength are investigated and proper connection parameters are proposed. The strength reduction factors corresponding to different connection types are proposed, which can be references for the design and analysis of membrane structures.

복합트러스교의 격점구조별 비틀림 거동 (Torsional Behavior of Hybrid Truss Bridge according to Connection Systems)

  • 정광회;이상휴;이종원;최지훈;김장호
    • 콘크리트학회논문집
    • /
    • 제25권1호
    • /
    • pp.63-72
    • /
    • 2013
  • 복합트러스교는 프리스트레스 박스거더교의 복부를 강재 트러스로 대체한 교량으로 자중이 경감되는 구조적 장점과 복부 개방구조로 인한 경관성이 매우 우수하여 최근 들어 많이 사용되고 있다. 이러한 복합트러스교의 핵심기술은 강재 트러스와 콘크리트 슬래브를 연결하는 격점구조이며 지금까지 여러가지 격점구조들이 개발되어 실험적 검증을 통해서 실교량에 적용해 오고 있다. 이러한 격점구조는 격점부 국부적인 거동뿐만 아니라 복합트러스 거더의 휨 및 피로 등 전체적인 거동을 좌우하기 때문에 이에 대한 연구가 계속 진행되고 있다. 한편, 복합트러스 교량의 복부 개방구조는 프리스트레스 박스교량에 비해 비틀림 성능을 저하시키는 단점을 가지고 있어 편심하중을 받는 교량이나 곡선교 등에는 아직까지 적용된 사례가 없다. 따라서 복합트러스교가 보다 널리 사용되기 위해서는 비틀림 거동에 대한 정확한 분석이 필요한 상황이다. 이 연구에서는 복합트러스교의 격점구조 형식에 따른 비틀림 거동 특성을 알아보기 위해서 3가지 형태의 박스형 복합트러스 실험체를 제작하여 비틀림 실험을 수행하고 분석해 보았다.

마찰 슬라이딩 거동을 보이는 건물 내 중량 설비의 내진성능 향상을 위한 감쇠기 연결 방안 (Damper Configuration for Seismic Performance Improvement of Heavy Facilities with Frictional Sliding Behavior inside Building)

  • 옥승용;박관순;이지호
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.53-61
    • /
    • 2020
  • This study proposes a new damper configuration for seismic performance improvement of heavy sliding facilities inside a building. For this purpose, we deal with two connection types of control system, and the parametric study has been performed to investigate their comparative seismic performances according to the variations of the control capacity. In order to simulate the seismic responses of the proposed system, we employed a recently-developed seismic response analysis method that can deal with the two-mass system with nonlinear frictional sliding behavior. The numerical results demonstrate that the typical method of diagonal bracing damper connection can exhibit effective control performance both on structure and the heavy sliding facilities, whereas the structure-facilities connection method does not show any control effect on both responses. On the other hand, the typical method has some limitations that it can adversely cause excessive sliding of the facilities, depending upon the frequency characteristics of structure and earthquake. On the contrary, the structure-facilities connection method is very effective in reducing the sliding displacement of the heavy facilities, even with small amount of control capacity. Thus, the following potential expectations can be inferred from these results: The typical diagonal bracing damper connection method will have some promising benefits in controlling the sliding facilities inside the building as well as the building itself, and the structure-facilities connection method can be a cost-effective way of protecting the internal heavy important facilities inside the structure already designed with sufficient seismic performance.

Investigation on the monotonic behavior of the steel rack upright-beam column connection

  • Cao, Yan;Alyousef, Rayed;Jermsittiparsert, Kittisak;Ho, Lanh Si;Alaskar, Abdulaziz;Alabduljabbar, Hisham;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.103-115
    • /
    • 2020
  • The cold-formed steel storage racks are extensively employed in various industries applications such as storing products in reliable places and storehouses before distribution to the market. Racking systems lose their stability under lateral loads, such as seismic actions due to the slenderness of elements and low ductility. This justifies a need for more investigation on methods to improve their behavior and increase their capacity to survive medium to severe loads. A standardized connection could be obtained through investigation on the moment resistance, value of original rotational stiffness, ductility, and failure mode of the connection. A total of six monotonic tests were carried out to determine the behavior of the connection of straight 2.0 mm, and 2.6 mm thickness connects to 5 lug end connectors. Then, the obtained results are benched mark as the original data. Furthermore, an extreme learning machine (ELM) technique has been employed to verify and predict both moment and rotation results. Out of 4 connections, increase the ultimate moment resistance of connection by 13% and 18% for 2.0 mm and 2.6 mm upright connection, respectively.

스터드 볼트 접합부의 인장 거동에 관한 연구 (Tensile Behavior of Stud Bolt Connections)

  • 이태석;김승훈;서수연;이리형;홍원기
    • 콘크리트학회논문집
    • /
    • 제13권4호
    • /
    • pp.321-328
    • /
    • 2001
  • 본 연구는 인장력을 받는 스터드 볼트 접합부에서 주근과 전단보강근이 스터드 볼트의 인장거동에 미치는 영향을 내력과 변형 면에서 검토한 것이다. 주근과 전단보강근이 스터드 볼트 접합부에 미치는 영향을 검토하기 위하여 8개의 실험체를 제작하여 연구하였다. 실험은 주근과 전단보강근량의 각기 다른 5개의 실험체와 접합상세 개발을 위한 3개의 실험체로 구성되었다. 실험결과를 통해서 주근은 스터드 볼트 접합부의 인장내력 상승에 효과가 있는 것으로 나타났으며, 전단보강근의 증가는 최대 내력이후 급격한 취성파괴방지에 효과가 있음을 보여주었다. C형(폐쇄형, 개방형)보강근, U형 보강근을 사용한 접합부는 스터드 볼트 전합부의 연성거동에 효과가 있음을 보여주었다. 기존실험결과 분석으로부터 CCD식에 의해 인장을 받는 접합부를 설계시, 강도감소계수를 0.75 ø로 사용할 것을 제시한다.

강판 콘크리트 구조 접합부의 설계방식에 따른 검증실험 연구 (A Study on Verification Tests according to Connection Design Methods of Steel Plate Concrete Structures)

  • 황경민;이경진;양현정;김원기
    • 한국강구조학회 논문집
    • /
    • 제26권1호
    • /
    • pp.1-10
    • /
    • 2014
  • 본 연구에서는 원전 구조물 내 철근 콘크리트 구조와 강판 콘크리트 구조가 이질접합된 경우를 모사하기 위하여, 상하부 표면강판 간에 타이바를, 상하부 리브재 간에 타이형강을 구성한 보형 실험체를 제작하여 실험체의 면외 휨 거동특성을 확인하고자 하였다. 실험결과, 실험체의 연성거동을 검증하였으며, 타이바와 타이형강이 콘크리트 및 강판의 분리를 방지함으로써 접합부의 취성파괴를 막아주고 있음을 확인하였다. 또한, #14 주철근으로 구성한 강판 콘크리트 구조 접합부에 대하여 두 가지 형태의 기계적 정착이음 방식에 따른 인장실험을 수행함으로써 본 방식의 설계 적정성을 평가하였다. 실험결과, 두 실험체 모두 주철근이 항복에 도달할 때까지 철근의 정착 및 연결 기능을 탄성한도 내에서 건전히 수행하고 있음을 확인하였다.

On Some Properties of Riemannian Manifolds with a Generalized Connection

  • Dehkordy, Azam Etemad
    • Kyungpook Mathematical Journal
    • /
    • 제56권4호
    • /
    • pp.1237-1246
    • /
    • 2016
  • In this paper we study some properties of submanifolds of a Riemannian manifold equipped with a generalized connection $\hat{\nabla}$. We also consider almost Hermitian manifolds that admits a special case of this generalized connection and derive some results about the behavior of this manifolds.

상·하부 T-stub 접합부의 초기회전강성 평가 (Evaluation of the Initial Rotational Stiffness of a Double Split Tee Connection)

  • 김희동;양재근;이재윤;이형동
    • 한국강구조학회 논문집
    • /
    • 제26권2호
    • /
    • pp.133-142
    • /
    • 2014
  • 상 하부 T-stub 접합부는 보와 기둥의 강성비, T-stub의 기하학적 형상변화, 긴결재의 개수, 패널존 효과 등의 영향에 따라서 보통모멘트골조 및 특수모멘트골조에 적합한 거동특성을 나타내는 완전강도 부분강접 접합부(full strength partial restrained connection)이다. 이러한 상 하부 T-stub 접합부가 구조적으로 안전하게 거동하기 위해서는 충분한 강도, 강성, 연성능력을 나타내어야 한다. 이 연구는 T-stub의 기하학적 형상변화가 상 하부 T-stub 접합부의 모멘트-회전각 관계에 미치는 영향을 파악하고, 이에 따른 상 하부 T-stub 접합부의 초기회전강성을 평가하기 위해 진행하였다. 이를 위하여 T-stub의 기하학적 형상변수 ${\alpha}^{\prime}$값을 변화시킨 2개의 상 하부 T-stub 접합부 실험체를 제작하여 접합부 실험을 수행하였고, 3차원 비선형 유한요소해석도 수행하였다.