• Title/Summary/Keyword: Connection and Transmission

Search Result 462, Processing Time 0.012 seconds

A study on the vibroacoustic reduction of refrigerator by controlling the transmission path of comp_mount system (압축기_마운트 시스템의 진동 전달경로 제어를 통한 냉장고 진동음 저감)

  • Kim, Jung-Seon;Thuy, Tran Ho Vinh;Kook, Jung-Hwan;Wang, Se-Myung;Lee, Dong-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.644-647
    • /
    • 2007
  • In this paper, we present our method of controlling the transmission path of compressor vibration to reduce the vibroacoustic of refrigerator. Firstly, to reduce the vibroacoustic radiated from compressor _ mount system, main transmission path was found experimentally and applied partial contact to transmission path to minimize the transmissibility from compressor operation to base plate. In order to verify our method, we designed changing of the connection part between grommet and base plate. Through experiment with modified connection part, we certificate experimentally the noise reduction of refrigerator. Finally, we apply previous connection part to grommet inner shape to enhance the effect of the system. From experimental results, we make certain the possibility of noise reduction of refrigerator through this approach.

  • PDF

Strong Connection Clustering Scheme for Shortest Distance Multi-hop Transmission in Mobile Sensor Networks (모바일 센서 네트워크에서 최단거리 멀티홉 전송을 위한 강한연결 클러스터 기법)

  • Wu, Mary
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.667-677
    • /
    • 2018
  • Since sensor networks consist of sensor nodes with limited energy resources, so efficient energy use of sensor nodes is very important in the design of sensor networks. Sensor nodes consume a lot of energy for data transmission. Clustering technique is used to efficiently use energy in data transmission. Recently, mobile sink techniques have been proposed to reduce the energy load concentrated on the cluster header near a sink node. The CMS(Cluster-based Mobile sink) technique minimizes the generation of control messages by creating a data transmission path while creating clusters, and supports the inter-cluster one-hop transmission. But, there is a case where there is no connectivity between neighbor clusters, it causes a problem of having a long hop data transmission path regardless of local distance. In this paper, we propose a SCBC(Strong connection balancing cluster) to support the path of the minimum number of hops. The proposed scheme minimizes the number of hops in the data transmission path and supports efficient use of energy in the cluster header. This also minimizes a number of hops in data transmission paths even when the sink moves and establishes a new path, and it supports the effect of extending the life cycle of the entire sensor network.

Transmission Pricing Methodology for Korean Wholesale Electricity Market (도매경쟁 전력시장에서의 송전요금 산정방식)

  • Lee, K.D.;Rhee, C.H.;Oh, T.K.;Park, B.Y.;Kim, Y.W.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.192-194
    • /
    • 2001
  • The Transmission network provides physical transport, network security, and connection services. The five principles of Transmission pricing are economic efficiency, cost recovery, efficient regulation, simplicity and transparency, non-discrimination. The Transmission Charges are made up of transmission connection charge and transmission charge of network. The Transmission Losses will be considered through Marginal Transmission Loss Factors in the market operation. The transmission loss rentals are used for the reduction of the annual revenue requirement of the transmission network for the purpose of derivation of transmission use of network charge.

  • PDF

A research on the design parameters for a double-transmission main system for sustainable water supply (이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구)

  • Hyun, Inhwan;Hong, Juneui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

Analysis of Characteristics of Connected-pile Foundations for Transmission Tower according to Changes of Load and Connection Beam Conditions in Clay (점토지반에서 하중특성 및 연결보조건에 따른 송전철탑용 연결형 말뚝기초의 특성 분석)

  • Kyung, Doohyun;Lee, Junhwan;Paik, Kyuho;Kim, Youngjun;Kim, Daehong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.10
    • /
    • pp.5-18
    • /
    • 2013
  • The differential settlement between the foundations causes the critical damage on the transmission tower constructed in soft ground. Connected-pile foundation for transmission tower structures is an option to prevent the differential settlement. It consists of main foundations and connection beams that are placed between the individual foundations at each corner of tower. In this study, 24 model pile load tests were conducted at a construction site in jeonlabuk-do to investigate the effects of the connection beams on transmission tower foundation. In model tests, various load conditions and connection beam conditions were considered. As the test results, the displacements of connected-pile foundation differed in accordance with load directions. The settlements of connected-pile foundation decreased with the increased stiffness of connection beams, lateral load capacity decreased in accordance with load height, and the lateral load capacity on the failure criteria was similar regardless of load direction.

Multimedia Home Network Middleware for Isochronous Connection Management based on IEEE1394-IEC61883 (IEEE 1394-lEC61883 기반 멀티미디어 홈 네트워크에서 등시성 연결 관리를 위한 미들웨어)

  • Lee Dong Kyu;Oh joo Yong;Park Jun Ho;Kang Soon Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12B
    • /
    • pp.1042-1051
    • /
    • 2004
  • The IEEE1394 is a favorable protocol for A/V networks recently in home and there are two types of transmission in this protocol which are asynchronous and isochronous. The more nodes participate in the IEEE1394 network, the more problems of resource exhaustion and connection repetition may occur. So this paper proposes a middleware for isochronous connection management and reliable multimedia data transmission in the IEEE1394-IEC61883 based home networks. In this paper, proposed middleware is supporting the various types of isochronous connection, guaranteeing the reliability of isochronous connection and providing the characteristic of a real-time data transmission. We support CORBA API for multimedia service and the proposed architecture was implemented using a test-bed and we verified the proposed architecture in a test-bed.

Performance enhancement of GSO FSS TCP/IP network (정지위성 TCP/IP 네트워크 전송 성능 향상)

  • Hong, Wan-Pyo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2B
    • /
    • pp.118-123
    • /
    • 2007
  • This paper studied the transmission control protocol over IP network to enhance the performance of the GSO satellite communication networks. The focus of this study is how to reduce the long round trip time and the transmission data rates over satellite link in the bidirectional satellite network. To do it, this study applied the caching and spoofing technology. The spoofing technology is used to reduce the required time for the link connection during communication. The caching technology is to improve the transmission bandwidth efficiency in the high transmission data rate link The tests and measurements in this study was performed in the commercial GSO communication satellite network and the terrestrial Internet network. The results of this paper show that the studied protocol in this paper highly enhance the performance of the bidirectional satellite communication network compare to the using TCP/IP satellite network protocol.

A Study for Stress Distribution of the High-voltage Transmission Tower Under Wind Forces (풍하중이 작용하는 고용량 송전철탑의 해석을 통한 응력 분포 고찰)

  • Chang, Jin-Won;Kim, Seung-Jun;Park, Jong-Sub;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.75-78
    • /
    • 2007
  • The structural methodology in designing a transmission tower have been performed to assume a simple truss behavior. But there're quite differences between a simple truss behavior and a real one. A suitable explanation for a structural stability can be expressed as a semi-rigid connection instead of the assumed hinged connection. This study proposes an alternative structural analysis modelling strategy for the transmission tower design. Proposed element models are truss element model, beam element model, and combined beam-truss element model. The static finite element analysis shows that there's a moment distribution between a mainpost member and the other bracing member.

  • PDF

An Unequal Divider based on Transmission Line with Periodic Capacitor Shunt Connection (캐패시터가 주기적으로 병렬 연결된 전송선로를 이용한 비대칭 분배기)

  • Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.781-786
    • /
    • 2012
  • In this paper, we propose the design and performance of an unequal divider using transmission line with periodic capacitor shunt connection. To design divider with a high dividing ratio, we limit a high impedance line value to fabricate microstrip line and also, design a low impedance line of below $10{\Omega}$ using periodic capacitor shunt connection. As a design example, a 10:1 ratio divider was designed and measured at center frequency 1 GHz to show the validity of the unequal divider using periodic capacitor shunt connection. Its performance is in good agreements with the simulated results.

Grounding method for Improving of the Characteristics on Cable TV Transmission Line (케이블 TV 전송선로의 특성 개선을 위한 접지방식)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Yeon, Che-Chin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF