• Title/Summary/Keyword: Confocal laser scanning microscope

검색결과 165건 처리시간 0.026초

치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화 (Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test)

  • 박정현;강신영;김종우;김장주;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제40권2호
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

SURFACE ANALYSES OF TITANIUM SUBSTRATE MODIFIED BY ANODIZATION AND NANOSCALE Ca-P DEPOSITION

  • Lee, Joung-Min;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.795-804
    • /
    • 2007
  • Statement of problem. Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known about their surface characteristics that have influence on tissue-implant interaction. Purpose. This study was aimed to investigate microtopography, surface roughness, surface composition, and wettability of the titanium surface modified by the anodic oxidation and calcium phosphate coating using IBAD. Material and methods. Commercially pure titanium disks were used as substrates. The experiment was composed of four groups. Group MA surfaces represented machined surface. Group AN was anodized surface. Group CaP/AN was anodic oxidized and calcium phosphate coated surfaces. Group SLA surfaces were sandblasted and acid etched surfaces. The prepared titanium discs were examined as follows. The surface morphology of the discs was examined using SEM. The surface roughness was measured by a confocal laser scanning microscope. Phase components were analyzed using thin-film x-ray diffraction. Wettability analyses were performed by contact angle measurement with distilled water, formamide, bromonaphtalene and surface free energy calculation. Results. (1) The four groups showed specific microtopography respectively. Anodized and calcium phosphate coated specimens showed multiple micropores and tiny homogeneously distributed crystalline particles. (2) The order of surface roughness values were, from the lowest to the highest, machined group, anodized group, anodized and calcium phosphate deposited group, and sandblasted and acid etched group. (3) Anodized and calcium phosphate deposited group was found to have titanium and titanium anatase oxides and exhibited calcium phosphorous crystalline structures. (4) Surface wettability was increased in the order of calcium phosphate deposited group, machined group, anodized group, sandblasted and acid etched group. Conclusion. After ion beam-assisted deposition on anodized titanium, the microporous structure remained on the surface and many small calcium phosphorous crystals were formed on the porous surface. Nanoscale calcium phosphorous deposition induced roughness on the microporous surface but hydrophobicity was increased.

생쥐 초기 2-세포 배에서 세포 내 칼슘 농도의 변화에 $Ni^{2+}$이 미치는 영향 (The effect of $Ni^{2+}$ on the intracellular $Ca^{2+}$ increase of the mouse early 2-cell embryos)

  • 윤숙영;이은미;배인하
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제30권4호
    • /
    • pp.269-280
    • /
    • 2003
  • Objective: We reported the overcoming effect of $Ni^{2+}$ on the in vitro 2-cell block of mouse embryos. In this study, we aim to investigate whether $Ni^{2+}$ should induce intracellular $Ca^{2+}$ transient in the mouse embryos. Materials and Methods: Embryos were collected at post hCG 32hr from the oviduct of the ICR mouse and cultured in M2 medium omitted phenol red. Intracellular $Ca^{2+}$ was checked by using a confocal laser scanning microscope and fluo-3AM by using various intracellular $Ca^{2+}$ antagonists. Results: In 1mM $Ni^{2+}$ treated medium which contained $Ca^{2+}$(1.71mM), 75.7% of the embryos showed $[Ca^{2+}]i$ transient about 200 sec later. In the $Ca^{2+}$-free medium, 69.8% of the embryos showed $[Ca^{2+}]i$ transient. In U73122, phospholipaseC(PLC) inhibitor (5uM, 10min) pretreated group, 33.3% of the embryos showed $[Ca^{2+}]i$ transient. Heparine, inositol 1, 4, 5-triphosphate receptor(IP3R) antagonist preinjected embryos showed no response with 1mM $Ni^{2+}$. In danthrolene treatment, ryanodine receptor(RyR)-antagonist, 43% embryos showed $[Ca^{2+}]i$ transient but they showed delayed response about 340sec in the presence of $Ca^{2+}$. Conclusions: Summing up the above results, $Ni^{2+}$ seems to induce $Ca^{2+}$-release from the $Ca^{2+}$-store even in the $Ca^{2+}$-free medium. IP3 receptors of the mouse 2-cell embryos might have an essential role for the intracellular $Ca^{2+}$ increase by $Ni^{2+}$.

Push-out bond strength and dentinal tubule penetration of different root canal sealers used with coated core materials

  • Sungur, Derya Deniz;Purali, Nuhan;Cosgun, Erdal;Calt, Semra
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.114-120
    • /
    • 2016
  • Objectives: The aim of this study was to compare the push-out bond strength and dentinal tubule penetration of root canal sealers used with coated core materials and conventional gutta-percha. Materials and Methods: A total of 72 single-rooted human mandibular incisors were instrumented with NiTi rotary files with irrigation of 2.5% NaOCl. The smear layer was removed with 17% ethylenediaminetetraacetic acid (EDTA). Specimens were assigned into four groups according to the obturation system: Group 1, EndoRez (Ultradent Product Inc.); Group 2, Activ GP (Brasseler); Group 3, SmartSeal (DFRP Ltd. Villa Farm); Group 4, AH 26 (Dentsply de Trey)/gutta-percha (GP). For push-out bond strength measurement, two horizontal slices were obtained from each specimen (n = 20). To compare dentinal tubule penetration, remaining 32 roots assigned to 4 groups as above were obturated with 0.1% Rhodamine B labeled sealers. One horizontal slice was obtained from the middle third of each specimen (n = 8) and scanned under confocal laser scanning electron microscope. Tubule penetration area, depth, and percentage were measured. Kruskall-Wallis test was used for statistical analysis. Results: EndoRez showed significantly lower push-out bond strength than the others (p < 0.05). No significant difference was found amongst the groups in terms of percentage of sealer penetration. SmartSeal showed the least penetration than the others (p < 0.05). Conclusions: The bond strength and sealer penetration of resin-and glass ionomer-based sealers used with coated core was not superior to resin-based sealer used with conventional GP. Dentinal tubule penetration has limited effect on bond strength. The use of conventional GP with sealer seems to be sufficient in terms of push-out bond strength.

Encapsulation of Lactobacillus rhamnosus GG Using Milk Protein-Based Delivery Systems: Effects of Reaction Temperature and Holding Time on Their Physicochemical and Functional Properties

  • Ayu, Istifiani Lola;Ha, Ho-Kyung;Yang, Dong-Hun;Lee, Won-Jae;Lee, Mee-Ryung
    • 한국축산식품학회지
    • /
    • 제41권5호
    • /
    • pp.894-904
    • /
    • 2021
  • Microencapsulation is a protective process for materials that are sensitive to harsh conditions encounted during food manufacture and storage. The objectives of this research were to manufacture a milk protein-based delivery system (MPDS) containing Lactobacillus rhamnosus GG (LGG) using skim milk powder and to investigate the effects of manufacturing variables, such as reaction temerpature and holding time, on the physiccohemical properties of MPDS and viability of LGG under dairy food processing and storage conditions. MPDS was prepared using chymosin at varing reaction temperatures from 25℃ to 40℃ for 10 min and holding times from 5 to 30 min at 25℃. The morphological and physicochemical properties of MPDS were evaluated using a confocal laser scanning microscope and a particle size analyzer, respectively. The number of viable cells were determined using the standard plate method. Spherical-shaped MPDS particles were successfully manufactured. The particle size of MPDS was increased with a decrease in reaction temperature and an increase in holding time. As reaction temperature and holding time were increased, the encapsulation efficiency of LGG in MPDS was increased. During pasteurization, the use of MPDS resulted in an increase in the LGG viability. The encapsulation of LGG in MPDS led to an increase in the viability of LGG in simulated gastric fluid. In addition, the LGG viability was enhanced with an increase in reaction temperature and holding time. In conclusions, the encapsulation of LGG in MPDS could be an effective way of improving the viability of LGG during pasturization process in various foods.

수크로스 에스터와 세라마이드를 혼합 겔레이터로 사용한 올레오겔과 올레오겔 에멀젼의 특성 분석 (Characterization of Oleogels and Oleogel Emulsions Made with Sucrose Ester and Ceramide as Mixed Gelators)

  • 이다연;진병석
    • 공업화학
    • /
    • 제34권5호
    • /
    • pp.501-506
    • /
    • 2023
  • 수크로스 에스터와 세라마이드를 혼합하여 겔레이터로 사용한 해바라기 오일의 올레오겔과 올레오겔 에멀전을 제조하였다. 올레오겔과 올레오겔 에멀젼 제형 내에서 겔레이터의 결정 구조는 편광현미경으로 관찰하고 물의 분산형태는 공초점 현미경으로 확인하였다. DSC 열차트 분석을 통해, 수크로스 에스터와 세라마이드를 혼합하면 세라마이드의 결정구조는 사라지고 제형에 물이 첨가되면 혼합된 겔레이터의 결정성이 더욱 상승함을 확인하였다. 제형에서의 수크로스 에스터, 세라마이드, 물의 비율에 따른 점도와 점탄성 등의 유변학적 특성의 변화를 살펴보았다. 세라마이드와 물의 함량이 증가할수록 점도 및 저장탄성률, 손실 탄성률 등이 모두 증가하고, 또한 제형의 안정성도 높아지는 경향을 보였다.

수종 air-turbine 다이아몬드 버의 절삭 효과에 관한 실험적 연구 (An experimental study of cutting efficiency of air-driven diamond burs on human tooth)

  • 홍진선;여인성;김성훈;이재봉;한중석;양재호
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.1-7
    • /
    • 2011
  • 연구 목적: 치과용 에어터빈에 장착하여 사용하는 다이아몬드 버는 치과 치료에서 치아 형성을 위한 필수적인 절삭용 회전 기구이다. 반복해서 사용되는 다이아몬드 버는 마모를 일으키게 되고 마모된 다이아몬드 버는 치아 형성시 열 발생, 절삭 효과 저하 등의 문제를 발생하게 된다. 본 연구의 목적은 자연치를 사용하여 coarse grit 다이아몬드 버의 절삭 효과를 비교하고자 하였다. 연구 재료 및 방법:임상에 널리 사용되는 coarse grit 다이아몬드 버 4종류를 선정하였다: Komet(A사), Shofu(B사), Premier(C사), Mani(D사). 발거된 상악 중절치의 순면을 사용하였다. 100g의 힘으로 6 mm 폭으로 10회 반복하여 실제 임상에서와 유사한 치아 형성을 하였다. 치아 형성을 하지 않은 coarse grit 다이아몬드 버를 대조군으로 하였고, 1개(test1), 2개(test2), 3개(test3), 그리고 4개(test4)의 치아 형성을 한 coarse grit 다이아몬드 버의 마모 양상을 공초점 레이저 주사 현미경으로 표면 거칠기 값을 다이아몬드 버의 첨부, 중간, 그리고 하단부 등의 3곳에서 측정하였고, 주사전자 현미경 (SEM)으로 표면 형태를 평가하였고, 표면 거칠기는 one-way ANOVA로 분석하였다. 결과: 공초점 레이저 주사 현미경으로 표면 거칠기를 측정하였다. A사의 coarse grit 다이아몬드 버의 경우 대조군의 표면 거칠기 값 (Sa)은 $52.98\;{\mu}m$인데 비해, test 1은 $48.32\;{\mu}m$, test 2는 $46.79\;{\mu}m$, test 3은 $45.06\;{\mu}m$, 그리고 test 4는 $43.43\;{\mu}m$을 보였다. B사 coarse grit 다이아몬드 버의 경우 각각 $50.68\;{\mu}m$, $45.62\;{\mu}m$, $44.41\;{\mu}m$, $44.10\;{\mu}m$, 그리고 $42.46\;{\mu}m$을, C사 coarse grit 다이아몬드 버의 경우 $58.02\;{\mu}m$, $55.53\;{\mu}m$, $52.22\;{\mu}m$, $48.26\;{\mu}m$, 그리고 $45.36\;{\mu}m$을, D사coarse grit 다이아몬드 버의 경우 $50.11\;{\mu}m$, $46.73\;{\mu}m$, $45.46\;{\mu}m$, $42.58\;{\mu}m$, 그리고 $41.80\;{\mu}m$을 보였다. 치아 형성한 횟수에 따라 각 coarse grit 다이아몬드 버에서 표면 거칠기의 변화는 통계적으로 유의하였으나, 각 시스템별 유의성은 관찰되지 않았다. SEM으로 관찰시 대조군에 비해 test 4에서 coarse grit 다이아몬드 버 입자의 마모를 관찰할 수 있었다. 결론: 치아 형성에 따른 coarse grit 다이아몬드 버의 표면 거칠기 값 (Sa)을 비교한 결과 각 치아 형성마다 통계적으로 유의한 차이를 보여 버를 수회 사용시 표면 거칠기가 상당히 감소할 것으로 보인다. Coarse grit 다이아몬드 버의 사용에 따른 각 제조회사별 차이를 비교한 결과는 통계적으로 유의한 차이를 보이지 않아 제조사에 따른 다이아몬드 버의 차이는 발견되지 않았다. Coarse grit 다이아몬드 버의 표면 특성을SEM으로 관찰한 결과, 대조군에 비해 test 4에서 다이아몬드 버 입자의 마모를 관찰할 수 있었다.

수종의 불소방출 수복재의 탈회억제 효과 및 불소침투에 관한 연구 (IN VITRO STUDY OF DEMINERALIZATION INHIBITION EFFECT AND FLUORIDE UPTAKE INTO ADJACENT TEETH OF LIGHT-CURED FLUORIDE-RELEASING RESTORATIVES)

  • 김송이;최성철;김광철;최영철;박재홍
    • 대한소아치과학회지
    • /
    • 제37권3호
    • /
    • pp.288-297
    • /
    • 2010
  • 자이오머(Giomer)는 레진강화형글라스아이오노머에 견줄 만큼 불소방출량이 많다고 하나, 우식예방 효과에 관한 연구들이 많지 않아 임상적용에 대한 근거가 부족한 실정이다. 본 연구는 자이오머(BF 군)를 포함하여 레진강화형글라스아이오노머(FF 군), 콤포머(DA 군)와 대조군인 콤포짓(FZ 군)의 우식억제 효과와 주변 치질로의 불소침투 양상을 비교하기 위하여, 공초점레이저주사현미경과 전자탐침미세분석기를 이용하여 각 수복재의 우식예방 효과를 비교하였으며, 다음과 같은 결과를 얻었다. 1. 수복물 주위 이차 인공우식에서 법랑질 외측병변의 깊이는 FZ 군에서 가장 깊었으며, BF 군이 가장 작게 나타났다(p<0.05). 2. 수복물과 법랑질 계면에 나타난 탈회억제층의 두께를 관찰한 결과 FZ 군이 가장 작게 나타났으며, FF, DA, BF 간에는 유의성 있는 차이를 보이지 않았다(p<0.05). 3. 법랑질에 침투된 불소농도는 BF, FF, DA의 순으로 높게 나타났다. 4. 상아질에 침투된 불소농도는 DA, BF, FF의 순으로 높게 나타났으며, 이는 상아질-수복물의 접착 계면에 영향 받는 것으로 보인다.

O/W 용매 증발법을 이용한 PLGA와 덱스트란의 이중층 미립구 제조 (Fabrication of PLGA/Dextran Double-Layered Microspheres by Oil-in-Water Solvent Evaporation Method)

  • 고종태;이재호;이창래;신형식;육순홍;김문석;강길선;이종문;이해방
    • 폴리머
    • /
    • 제29권6호
    • /
    • pp.543-548
    • /
    • 2005
  • 이중층 미립구는 단일층 미립구에 비해서 낮은 초기 방출량과 국소 지항성, 및 약물 방출량 제어 등의 장점 을 갖고 있다. 그러나 포접 방식이 까다롭고 2단계 이상의 제조 과정이 필요하며 특히 미립구 제조 시 크기 조절이 어렵다는 단점을 갖고 있다. 따라서 본 연구에서는 락타이드글리콜라이드 공중합체(PLGA)와 덱스트란의 서로 다른 고분자를 초고주파 분쇄 유무에 따른 수중유형(O/W) 용매 증발법을 이용하여 이중층 미립구를 제조하였다. 또한 PLGA의 농도에 따라 미립구 크기의 변화를 연구하였다. 이중층 미립구는 전자주사현미경, 동초점 형광 레이저현미경(CFLM), 캠스코프를 이용하여 조사하였다. 제조된 이중층 미립구의 외부층이 매끄러운 구형의 형태를 나타냄을 확인할 수 있었으며, 절단시 내부층과 외부층의 형태를 확실히 구분할 수 있었다. 이에 외부층과 내부층의 구성 물질을 확인하고자 플루오르신-5-이소시아네이트-덱스트란(FITC-덱스트란)을 이용해 CFLM을 관찰한 결과 형광을 띠는 덱스트란으로 구성된 내부층과 형광을 띠지 않는 PLGA 외부층을 관찰하였다. 또한 PLGA의 함량에 따른 미립구의 크기는 전체적으로 증가하는 경향을 확인하였다. 이와 같은 결과로부터 비교적 간단한 수중유형 용매 증발법을 이용하여 PLGA와 덱스트란의 이중층 미립구의 제조가 가능함을 확인할 수 있었다.

인삼 적변현상과 적변물질의 형태-화학적 특성 (Red-Colored Phenomena and Morphochemical Characteristics of Red-Colored Substances in Ginseng Roots (Panax ginseng C.A. Meyer))

  • 윤길영;양덕조
    • Journal of Ginseng Research
    • /
    • 제24권3호
    • /
    • pp.107-112
    • /
    • 2000
  • 적변삼 표피조직의 적갈색의 침적물은 강력한 산화제에 의해서만 산화(탈색)되는 chelation power가 매우 큰 화학결합을 형성하고 있었다. CLSM으로 관찰한 결과, 적변삼 조직의바깥쪽으로 두껍게 침적물이 형성되어 있음이 확인되었으며, 조직의 형광강도를 이용하여 두께를 측정한 결과 약 120rm의 침적물이 축적되어 있음이 확인되었다. 또한 Spectrum분석 결과 적변삼 표피의 물질은 건강삼의 표피조직과는 다른 functional group을 포함하는 것으로 확인되었다. 건강삼과 적변삼의 표피조직을 강산과 강염으로 가수분해 하여도 조직에 침적되어 있는 적색의 물질은 용출되지 않았다. 적변삼과 건강삼의 표피조직과 뿌리의 각 부위별 총 페놀성화합물의 함량을 측정한 결과, 건강삼의 표피조직에서 가장 높게 나타났다. 이러한 결과는 페놀성 물질이 적변물질의 원인이 된다는 보고와 차이가 있는 것으로 페놀성 물질은 적변현상 유발의 직접적인 원인물질이 아님이 확인되었다. 따라서 인삼의 적변물질은 인삼뿌리의 유기성분(세포벽 분해산물, 세포내용물, azodicarbonamide 등)과 철이온 복합체로 추론되며, 이물질에 대한 계속적인 추적을 진행하고 있다.

  • PDF