• 제목/요약/키워드: Confocal Scanning Microscope

검색결과 198건 처리시간 0.028초

공초점 주사현미경을 통한 미세 유로에서의 유동 가시화 (Flow Visualization in Microchannel Using Confocal Scanning Microscope)

  • 장준근;박성진;김중경;한동철
    • 한국가시화정보학회지
    • /
    • 제1권1호
    • /
    • pp.28-33
    • /
    • 2003
  • This paper presents the visualization method in which 3-dimensional(3D) microchannel flow can be detected using a confocal scanning microscope. By soft-lithography, we fabricated various Bio-MEMS(Micro Electro-Mechanical System) devices such as a disposable microchip for a flow cytometer and a micro-mixer, which have 3D structures. Injecting aqueous fluorescent solution in the microfluidic devices, we measured the flow in a steady state by the confocal scanning microscope. At first, we explain the principle of the confocal scanning microscope. And then we show the results from 3D visualization of microscopic flow structures using the confocal scanning microscope.

  • PDF

Signal increasing method in confocal scanning microscopy in fluorescence mode using curved mirror

  • Kang, Dong-kyun;Seo, Jung-woo;Gweon, Dae-gab
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.99.3-99
    • /
    • 2001
  • In fluorescence mode confocal scanning microscope, level of detected signal is very low. In object scanning type confocal scanning microscope, the additional optical system with objective lens and plane mirror was proposed to increase signal intensity, but there was none for beam scanning type confocal scanning microscope. We propose reflecting optical systems which improve signal intensity in beam scanning type confocal scanning microscope. We choose one of the proposed optical systems and design the optical system, i.e., select optical components and assign distances between the selected components. To design the optical system, we use finite ray tracing method and make cost function to be minimized.

  • PDF

4분할 photodiode를 이용한 scanning confocal microscope (Scanning confocal microscope using a quad-detector)

  • 유석진;김수철;이진서;권남익
    • 한국광학회지
    • /
    • 제8권2호
    • /
    • pp.165-168
    • /
    • 1997
  • 780 nm의 반도체 레이저, compact disk의 광 pick-up용 actuator, 그리고 4분할 photodiode를 이용하여 scanning confocal microscope를 구성하여 시료면의 높이와 재질의 차이를 측정하였다. 4분할 photodiode에 검출되는 오차 신호를 이용하여 렌즈가 장착되어 있는 actuator를 움직이면서 시료면에 레이저 광속의 초점이 항상 위치하도록 하였으며, 이 때 actuator에 흐르고 있는 전류를 시료면의 높이로 나타내어 3차원 영상으로 표현하였다. 또한 재질의 차이는 4분할 photodiode에 검출되는 합산 신호를 이용하여 컬러 프린터에 나타나는 3차원 영상의 색을 다르게 나타내었다. 전체적인 크기도 30 mm * 20 mm * 20 mm 로서 작고 간단하며 scan 영역은 최대 1.6 mm * 1.6 mm이다. 반사광의 세기를 이용한 scanning confocal microscope의 영상과 4분할 photodiode에 검출되는 오차 신호를 적분하는 방식을 이용한 scanning confocal microscope의 영상을 구하여 그 차이를 비교하였다.

  • PDF

Monte Carlo 방법을 이용한 공초점 주사 현미경의 오차 분석과 정렬 공차 할당에 관한 연구 (Error Analysis and Alignment Tolerancing for Confocal Scanning Microscope using Monte Carlo Method)

  • 유홍기;강동균;이승우;권대갑
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.92-99
    • /
    • 2004
  • The errors can cause the serious loss of the performance of a precision machine system. In this paper, we proposed the method of allocating the alignment tolerances of the parts and applied this method to get the optimal tolerances of a Confocal Scanning Microscope. In general, tight tolerances are required to maintain the performance of a system, but a high cost of manufacturing and assembling is required to preserve the tight tolerances. The purpose of allocating the optimal tolerances is minimizing the cost while keeping the high performance of the system. In the optimal problem, we maximized the tolerances while maintaining the performance requirements. The Monte Carlo Method, a statistical simulation method, is used in tolerance analysis. Alignment tolerances of optical components of the confocal scanning microscope are optimized to minimize the cost and to maintain the observation performance of the microscope. We can also apply this method to the other precision machine system.

공초점 원리를 이용한 표면 현상 측정 (Surface measurement using Confocal principle)

  • 송대호;유원제;강영준;김경석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.51-54
    • /
    • 2000
  • The traditional surface measuring method using confocal principle requires much time to measure an object surface since it is a scanning tool. In this paper, the upgraded confocal microscope is introduced. It is also a scanning tool but it requires 2D-scanning while the traditional one requires 3D-scanning. It means the time for measuring is considerably reduced. In addition, the measuring system is configured to increase the efficiency of beam. He-Ne laser whose frequency is 632.8nm is used for the laser source. An example of measuring result through the upgraded confocal microscope is showed.

  • PDF

광섬유의 직접 구동에 의한 공초점 현미경 (Scanning confocal microscope by direct oscillation of an optical fiber)

  • 김종배;류광현;박두성;노정은;권남익
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.80-84
    • /
    • 2003
  • 두 가지의 다른 방법으로 광섬유를 직접 구동하여 공초점 현미경을 제작하였다. 압전소자와 튜닝 포크는 광섬유를 진동시키는데 사용하였다. 6 frame의 640$\times$480 픽셀 영상을 압전소자 진동으로 1초 동안 얻었고, 1 frame의 640$\times$480 픽셀 영상을 튜닝 포크 진동으로 1초 동안 얻었다 이러한 광섬유의 진동은 confocal 영상에 일그러짐을 주지 않았다.

4분할 광검출기를 이용한 표면 추적 효과의 공초점 현미경 (Scanning confocal microscope of a surface following effect using a quad-detector)

  • 김수철;송장섭;권남익
    • 한국광학회지
    • /
    • 제9권1호
    • /
    • pp.1-4
    • /
    • 1998
  • CD-Player에서 사용되고 있는 4분할 광검출기를 이용하여 작고 간단하며 표면 추적 효과를 가지는 공초점 현미경을 구성하였다. 구성한 공초점 현미경은 4분할 광검출기에서 검출되는 오차 신호의 거리에 따른 변화를 이용하였다. 초점 근처에서 민감하게 변하며 양극성인 성질을 가지는 오차 신호를 이용하여 표면 추적을 하지 않아도 정확한 높이 변화를 알 수 있는 표면 추적 효과를 얻었다. 또한 시료의 높이 차이가 크지 않을 경우 반사 신호를 통하여 재질의 차이까지 알 수가 있다. 구성한 공초점 현미경은 간단한 조작으로 반사 신호를 이용하여 영상을 구현할 수도 있어 두 방식으로 얻은 결과를 비교, 분석하였다.

  • PDF