• Title/Summary/Keyword: Confocal Image

Search Result 103, Processing Time 0.032 seconds

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Graded Noise Elimination and Cluster Boundary Extraction in Confocal Sliced Images (공초점 단층 이미지에서 수준별 잡음제거와 클러스터 경계선 추출)

  • Cho, Mi-Gyung;Kim, Jin-Seok;Shim, Jae-Sool
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.12
    • /
    • pp.2697-2704
    • /
    • 2011
  • In tissue engineering area, researchers observe symbiotic relationship such as proliferation, interaction, division apoptosis with time between cells in process of the 3D cell culture in hydrogels. The 3D cell culture process can be taken photographs into sliced images using confocal microscope. Symbiotic mechanism and changes of cell behaviors can be observed and analyzed from the images acquired by confocal microscope. In this paper, we proposed and developed graded noise elimination method and cluster boundary extraction method to extract boundaries information from sliced confocal images acquired in process of the 3D cell culture in hydrogels. The experiment based algorithm showed excellent performance for eliminating noises that have very small millet-shaped size. It is also showed to extract exact boundaries information for even complex clusters.

Confocal laser scanning microscopy image를 이용한 UASB granule의 메탄 생성 능력 측정

  • Lee, Yu-Jin;Kim, Hyo-Seop;An, Yeong-Hui;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.365-369
    • /
    • 2000
  • Methanogenic activity of granular sludge was monitored by specific methanogenic activity (SMA) assay and confocal laser scanning microscopy (CLSM) during start-up of a thermophilic UASB reactor. Autofluorescence by CLSM could visualize the methanogenic bacterial population inside sludge granules and its intensity was proportional to SMA. Considering the complex procedures of SMA measurement, fluorescence quantification by CLSM can be suggested as a routine technique measuring methanogenic activity in UASB granules.

  • PDF

Development of confocal scanning microscopy using acousto-optica1 deflector

  • J.W. Seo;D.K. Kang;H.G. Yun;Kim, K.H.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.161.6-161
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has an important role as the three-dimensional profiler. An image distribution can be reconstructed by a correlation analysis of spots with the bandwidth of radio frequency. But it is a serious problem for the high performance to align the optical components. Especially, the parasitic motion of focus on the detector gives rise to the fatal distortion of an image profile named the extinction effect while using acousto-optical(AO) deflector. An image profile can be regenerated in CSM with many advantages of non-contact, high speed and high resolution comparatively. In addition to the axial response of the primary focus, the lateral movement of it gives a necessity of the unitary lens to the scanning system. While using the beam deflector, the pupil of beam may be fixed at the nominal position. Furthermore, the use of a deflector may result in ...

  • PDF

Measurements of Defects after Machining CFRP Holes Using High Speed Line Scan (고속 라인 스캔 방식을 이용한 CFRP 가공 홀 표면 및 내부 결함 검사)

  • Kim, Teaggyum;Kyung, Daesu;Son, Unchul;Park, Sun-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Using a line scan camera and a Galvano mirror, we constructed a high-speed line-scanning microscope that can generate 2D images ($8000{\times}8000pixels$) without any moving parts. The line scanner consists of a Galvano mirror and a cylindrical lens, which creates a line focus that sweeps over the sample. The measured resolutions in the x (perpendicular to line focus) and y (parallel to line focus) directions are both $2{\mu}m$, with a 2X scan lens and a 3X relay lens. This optical system is useful for measuring defects, such as spalling, chipping, delamination, etc., on the surface of carbon fiber reinforced plastic (CFRP) holes after machining in conjunction with adjustments in the angle of LED lighting. Defects on the inner wall of holes are measured by line confocal laser scanning. This confocal method will be useful for analyzing defects after CFRP machining and for fast 3D image reconstruction.

STUDY OF INCIPIENT ENAMEL CARIES USING A DIGITAL ILLUMINATION FIBER-OPTIC TRANSILLUMINATION AND CONFOCAL LASER SCANNING MICROSCOPE (Digital Imaging Fiber-Optic Trans-Illuminational과 Confocal Laser Scanning Microscope를 이용한 초기 법랑질 우식증 연구)

  • Kim, Jae-Tae;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The purpose of this study were to evaluate the efficacy of the newly developed Digital Imaging Fiber-Optic Trans-illumination (DIFOTI) system in detecting carious lesions in vivo as gold standard with confocal laser scanning microscopy and compared the efficacy of traditional radiography and DIFOTI system in vito as gold standard with confocal laser scanning microscopy, too. For the in vivo study, the subject pool consisted of 23 grammar school age patients just prior to entering the mixed dentition phase Each patient was given a DIFOTI examination of the anterior and posterior teeth. During $6{\sim}8$ months, the naturally expire primary teeth were collected and the efficacy of DIFOTI system was compared with confocal laser scanning microscopy. For in vitro study, 40 primary teeth were collected and decalcified by Carbopol decalcification solution for 1, 2, 4 and 8 days. Every experiment period, all teeth were DIFOTI examined and sectioned to take an image of confocal laser scanning microscopy Sensitivity and specificity were calculated from the result of DIFOTI examine and confocal laser scanning microscopy analysis. The results are as follows : 1. From the in vivo study, the sensitivity of DIFOTI examine was 0. 61 and specificity was 0.63. 2. From the in vivo study, the sensitivity of DIFOTI examine was 0.71 and specificity was 0.75.

  • PDF

Fiber Orientation in Injection-Molded Short Fiber Composites with a Confocal Laser Scanning Microscope and Numerical Simulation (공초점 레이저 주사 현미경을 이용한 단섬유 복합재료 사출 성형물 내의 섬유 배열 측정 및 수치모사)

  • Lee, Kwang-Seok;Le, Seok-Won;Youn, Jae-Ryoun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.201-204
    • /
    • 2001
  • A Confocal Laser Scanning Microscope (CLSM) is applied to determine three-dimensional fiber orientation states in injection-molded short fiber composites. Since the CLSM optically sections the composites, more than two planes either on or below the surface of composites can be obtained. Therefore, three dimensional fiber orientation states are determined without destruction. To predict the orientation states, velocity and temperature fields are calculated by using a hybrid FEM/FDM method. The change of orientation state during packing stage is also considered by employing a compressible Hele-Shaw model. The predicted orientation states show good agreement with measured ones. However, some differences are found at the end of cavity. They may result from other effects, which are not considered in the numerical analysis.

  • PDF

Scanning confocal microscope of a surface following effect using a quad-detector (4분할 광검출기를 이용한 표면 추적 효과의 공초점 현미경)

  • 김수철;송장섭;권남익
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.1
    • /
    • pp.1-4
    • /
    • 1998
  • A compact scanning confocal microscope has been constructed using a quad-detector in a CD-player. The variation of error signal on depth which obtained by a quad-detector is used in the scanning confocal microscope. Bipolar error signals, which is sensitive near a focus, give a surface following effect whiout following the surface. In the case of small depth difference, the difference of materials through the reflection signal has been identified. The image which uses reflection signal only, has been obtained with the same setup. And, the results obtained in two different way were compared and analyzed.

  • PDF

Design of spectrally encoded real-time slit confocal microscopy (파장 코딩된 실시간 슬릿 공초점 현미경의 설계)

  • Kim Jeong-Min;Kang Dong-Kyun;Gweon Dae-Gab
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.576-580
    • /
    • 2005
  • New real-time confocal microscopy using spectral encoding technique and slit confocal aperture is proposed and designed. Spectral encoding technique, which encodes one-dimensional spatial information of a specimen in wavelength, and slit aperture make it possible to obtain two-dimensional lateral image of the specimen simultaneously at standard video rates without expensive scanning units such as polygon mirrors and galvano mirrors. The working principle and the configuration of the system are explained. The variation in axial responses for the simplified model of the system with normalized slit width is numerically analyzed based on the wave optics theory. Slit width that directly affects the depth discrimination of the system is determined by a compromise between axial resolution and signal intensity from the simulation result. On the assumption of the lateral sampling resolution of 50 nm, design variables and governing equations of the system are derived. The system is designed to have the mapping error less than the half pixel size, to be diffraction-limited and to have the maximum illumination efficiency. The designed system has the FOV of $12.8um{\times}9.6um$, the theoretical axial FWHM of 1.1 um and the lateral magnification of-367.8.

  • PDF