• Title/Summary/Keyword: Confidence Evaluation

Search Result 787, Processing Time 0.026 seconds

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Small-Sample Inspection Plans for the New Product Quality Level Evaluation of Finite Population : Focused on Guided Weapons in Development Stage (생산수량이 한정된 신제품의 품질수준 평가를 위한 샘플링검사 방법 : 개발단계 유도무기를 중심으로)

  • Shin, Byung-Cheol;Byun, Jai-Hyun;Lee, Chang-Woo;Lee, Ki-Yong;Choi, Jong-Soo;Woo, Hee-Sung;Seo, Bo-Gil
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.5
    • /
    • pp.481-487
    • /
    • 2015
  • In the product development stage, it is very important to ensure demanded quality level before moving to the full-scale manufacturing. For example, in developing guided weapons, live-fire tests are required to verify the final performance of the weapons which are very expensive. The quality evaluation of the guided weapons needs destructive testing, which makes it necessary to test as small number of samples as possible. This paper presents sampling inspection plans and calculating system for finite population guided weapons, which can meet the demanded quality level and confidence level with the minimum number of performance tests. The result of this paper can be useful for any kind of costly destructive testing.

Validity of the Wii Balance Board for Evaluation of Medial Patellar Luxation in Small Sized Dog

  • Lee, Shinho;Lee, Joo-Myoung;Park, Hyunjung;Cha, Yuri;Cheong, Jongtae
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.297-300
    • /
    • 2019
  • Wii® balance board (WBB) is a device that can measure and record body sway. This study was conducted to evaluate the reliability of WBB in small sized dog as inexpensive, portable and convenient tool. The center of pressure path length (CPPL) and 95% confidence ellipse area (Area 95) were evaluated with only two plates of WBB. The parameters were evaluated between no load (0 kg) and mass group (0.25-4 kg on each one plate). 23 dogs (2.3-7.3 kg) were evaluated for with hindlimb standing for 10 seconds. The mass group showed a significant value in comparison to the no load during the measurement. And intra-class correlation coefficients (ICCs) between CPPL and Area 95 revealed very high both mass and dog group. In the evaluation of medial patellar luxation (MPL) as a diagnostic tool, 80 dogs with MPL and 23 non-affected dogs were used. In studies of CPPL and Area 95, significant differences were found between non-affected and MPL groups for 10 and 30 seconds, respectively. The WBB can be used as a valid tool for evaluating hind limb standing balance and can be useful as an objective tool to present clinical results in small sized dog with MPL.

Effect of pre-educational evaluation on CPR education of the General population (일반인의 심폐소생술 교육에 대한 사전 교육 평가의 영향)

  • Yang, Hyun-Mo;Kim, Gyoung-Yong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.105-111
    • /
    • 2021
  • The purpose of this study is to determine how the pre-test performed before training affects the results of CPR performance. In the case of the pre-test group(PTG), a pre-evaluation was performed for 1 minute before training, and the group that did not perform the pre-test(NPTG) performed only regular education. In both groups, skill test was performed for 1 minute after training. As a result of comparing the pre and post-test of PTG, there were statistically significant changes in chest compression depth, rate, and compression recoil. There was a statistically significant difference only in the chest compression rate in the chest compression performance results of the two groups after training. There was a statistically significant difference in the results of confidence after training in both groups. It is judged that the pre-test conducted before training has a good influence not only on the results of chest compression, but also on confidence improvement. Therefore, it is judged that it is necessary to develop additional programs such as pre-education test in order to increase the concentration of CPR education for the general population.

A Study of the Method for External Noise Shielding using the GIS UHF Sensor Module Applied to the Partial Discharge Signal Sensitivity and Method of Frequency Transforming in the Internal GIS (GIS내부의 부분방전신호 감도개선 및 주파수변환기법에 의한 GIS UHF Sensor 모듈의 외부노이즈차폐기법에 관한 연구)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.728-732
    • /
    • 2010
  • GIS(Gas insulated switching gear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. Recently, because equipment of GIS was occurring problem of confidence used for a long time, partial discharge on-line diagnosis systems have been importantly recognized. Partial discharge (PD) detection is an effective means for monitoring and evaluation of dielectric condition of gas insulated system (GIS). The ultra-high-frequency (UHF) PD detection technique can detect and locate the PD sources inside GIS by detecting electromagnetic wave emitted from PD source. Therefore, real-time diagnostic system using UHF detection method has been developed for this application is being expanded gradually. However, the signal of partial discharge occurring in SF6 gas is very weak and susceptible to external noises which mainly consist of PD in air. Thus, it is important to distinguish the PD in SF6 gas more sensitively from the external noises. Unfortunately, these external noise signals and the partial discharge signals have very similar characteristics. Therefore, to solve this problem, we need the signal processing method for distinguish partial discharge signals with external noise signals for improvement of SNR(signal to noise ratio) and sensitivity. In this paper, we proposed internal signal processing method for removing external noise signals with built-in pre.amplifier and frequency conversion circuit.

A Study on the Combustion Stability Evaluation of Double Swirl Coaxial Injector (이중 와류 동축형 분사기의 연소안정성 평가에 관한 연구)

  • ;;;Kim, Hong-Jip;Choe, Hwan-Seok;Lee, Su-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.12
    • /
    • pp.41-47
    • /
    • 2006
  • A liquid rocket thrust chamber should have a high confidence in its combustion performance and combustion stability. Expecially, the injector of which function is spraying and mixing propellants plays an important role in getting the confidence. This study was carried out to evaluate combustion stability of a double swirl coaxial injector by using the model similarity method. Besides, in case of a baffle which was used to improve combustion stability, the length and gap effects of the baffle were investigated.

Damage states of yielding and collapse for elevated water tanks supported on RC frame staging

  • Lakhade, Suraj O.;Kumar, Ratnesh;Jaiswal, mprakash R.
    • Structural Engineering and Mechanics
    • /
    • v.67 no.6
    • /
    • pp.587-601
    • /
    • 2018
  • Elevated water tanks are inverted pendulum type structures where drift limit is an important criterion for seismic design and performance evaluation. Explicit drift criteria for elevated water tanks are not available in the literature. In this study, probabilistic approach is used to determine maximum drift limit for damage state of yielding and damage state of collapse for the elevated water tanks supported on RC frame staging. The two damage states are defined using results of incremental dynamic analysis wherein a total of 2160 nonlinear time history analyses are performed using twelve artificial spectrum compatible ground motions. Analytical fragility curves are developed using two-parameter lognormal distribution. The maximum allowable drifts corresponding to yield and collapse level requirements are estimated for different tank capacities. Finally, a single fragility curve is developed which provides maximum drift values for the different probability of damage. Further, for rational consideration of the uncertainties in design, three confidence levels are selected and corresponding drift limits for damage states of yielding and collapse are proposed. These values of maximum drift can be used in performance-based seismic design for a particular damage state depending on the level of confidence.

A Study on Mechanical Properties Changes to Improve the Confidence of Remaining Life Evaluation for the Weldment of Power Plant Boiler Tube(SA213-T12) (발전설비 보일러 튜브 용접부의 잔여수명평가 신뢰성 향상을 위한 기계적 물성 변화 연구(SA213-T12))

  • Oh, Byungjin;Jang, Joong Soon
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.102-107
    • /
    • 2014
  • Boiler equipment in power plant is always being operated in harsh conditions and severely exposed to the extreme environment of high temperature. Therefore periodically the state of devices should be checked, diagnosed, and analyzed to ensure the reliability of the equipment. Traditionally, such a diagnosis is based one or two physical properties of the sample taken from the equipment like hardness, microstructure, etc.. However, to enhance the confidence of the diagnosis, it is necessary to synthesize those properties together. This paper is to propose such a synthetic procedure for SA213-T12(1Cr-0.5Mo) which was developed to be used in $565^{\circ}C$ below condition. Creep test and accelerated degradation test were performed simultaneously, and the physical properties such as microstructure, tensile strength, yield strength, hardness, and indentation properties were measured. This paper proposes a method of determining the remaining life by quantitative comparison. It will provide the basis of evaluating life assessment more objective and reliable.

P-value significance level test for high-performance steel fiber concrete (HPSFC)

  • Abubakar, Abdulhameed U.;Akcaoglu, Tulin;Marar, Khaled
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.485-493
    • /
    • 2018
  • Statistical analysis has found useful application in the design of experiments (DOE) especially optimization of concrete ingredients however, to be able to apply the concept properly using computer aided applications there has to be an upper and lower limits of responses fed to the system. In this study, the production of high-performance steel fiber concrete (HPSFC) at five different fiber addition levels by volume with two aspect ratios of 60 and 83 were studied under two curing methods completely dry cured (DC) and moist cured (MC) conditions. In other words, this study was carried out for those limits based on material properties available in North Cyprus. Specimens utilized were cubes 100 mm size casted and cured for 28 days and tested for compressive strength. Minitab 18 statistical software was utilized for the analysis of results at a 5 per cent level of significance. Experimentally, it was observed that, there was fluctuation in compressive strength results for the two aspect ratios and curing regimes. On the other hand P-value hypothesis evaluation of the response showed that at the stated level of significance, there was a statistically significant difference between dry and moist curing conditions. Upper and lower limit values were proposed for the response to be utilized in DOE for future studies based on these material properties. It was also suggested that for a narrow confidence interval and accuracy of the system, future study should increase the sample size.

A Sampling-based Algorithm for Top-${\kappa}$ Similarity Joins (Top-${\kappa}$ 유사도 조인을 위한 샘플링 기반 알고리즘)

  • Park, Jong Soo
    • Journal of KIISE:Databases
    • /
    • v.41 no.4
    • /
    • pp.256-261
    • /
    • 2014
  • The problem of top-${\kappa}$ set similarity joins finds the top-${\kappa}$ pairs of records ranked by their similarities between two sets of input records. We propose an efficient algorithm to return top-${\kappa}$ similarity join pairs using a sampling technique. From a sample of the input records, we construct a histogram of set similarity joins, and then compute an estimated similarity threshold in the histogram for top-${\kappa}$ join pairs within the error bound of 95% confidence level based on statistical inference. Finally, the estimated threshold is applied to the traditional similarity join algorithm which uses the min-heap structure to get top-${\kappa}$ similarity joins. The experimental results show the good performance of the proposed algorithm on large real datasets.