• Title/Summary/Keyword: Conference room

Search Result 2,361, Processing Time 0.038 seconds

Investigation of the Indoor Noise of Naval Vessel according to the Sound Absorption and Reverberation Time in a Cabin (함정 격실에 적용되는 흡음재와 잔향시간에 따른 실내 소음 분석)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been;Son, Yoon-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.586-591
    • /
    • 2010
  • The sound field can be classified to the direct and reverberant sound field. If the sound absorption material in a room is not applied sufficiently, the reverberant sound field increases and the sound pressure in a room also increases when the sound source exists in a room. Therefore, the reverberation time should be controled in order to reduce the reverberant sound as well as sound pressure level in a room. Even though the reverberation time is specified and researched widely in architectural engineering, it is rarely performed in a marine engineering. Therefore, in this research, the reverberation time in a navel vessel is researched related to the noise reduction in a cabin.

  • PDF

Analysis on Reduction Effect of Hydraulic Turbine Dynamo Noise using Acoustic Simulation (음향시뮬레이션을 이용한 수차 발전기소음의 저감효과 분석)

  • Jung, Eun-Jung;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.248-252
    • /
    • 2007
  • As Waterpower Generation generates electricity using the difference of altitude of water, also let the turbine revolves through water pipe, at this time the revolving turbine causes exceedingly huge noise. Accordingly, not only those workers in the hydraulic turbine dynamo room are suffering the difficulties in mutual communication, but also those workers in the adjacent office are enduring the obstruction to the business due to the noise. Therefore, this Study has analyzed the reduction effect on the noise of hydraulic turbine dynamo room utilizing computer simulation, through the preceding research with the optimized model for architectural acoustic factor of the hydraulic turbine dynamo room. It is considered that such research result could be applied as the useful material for improvement of acoustic performance and noise-reduction effect at other similar hydraulic turbine dynamo room in the future.

  • PDF

FIR ROOM RESPONSE CORRECTION SYSTEM (FIR 필터를 사용한 청취 환경 보정 시스템)

  • Arora Manish;Sung Ho-Young;Lee Hyuck-Jae;Lee Joon-Hyon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.283-286
    • /
    • 2004
  • Due to advances in electronics very high quality audio reproduction is today possible. But the listening environment causes deviation of the audio system from the expected behavior. Firstly the listening Room significantly changes the audio signal frequencies and their phase. Secondly the position of the user in the room affects the perceived sound. With existing DSP technology it is possible to adequately correct these effects. In our work we developed a room correction system, correcting up to 7.1 channels using dual Motorola 56367 fixed point DSP's, implementing position dependent room effects measurement, real time compensation filter design and equalization filtering procedures.

  • PDF

Assessment of Risk Component for Electrical Safety of Computer Room in School (학교 컴퓨터실의 전기안전에 대한 리스크요소 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.440-445
    • /
    • 2007
  • This paper deals with assessment of risk component for electrical safety and investigation on the spot of computer room in elementary middle high school. The investigation was carried out side by side for floor, outlet, panel board, earth leakage circuit breaker at computer room In order to assess electrical safety at computer room, grounding simulator and power quality monitor have been used. Potential rise has been measured and analyzed for ground rod and grounding grid by using the simulator. Phase and neutral-line current have been monitored in real time. As a consequence, it is desirable for us to install conductive tile at floor of computer room Grounding grid had better than ground rod for electrical safety. Neutral-line current was produced by unbalanced phase current.

  • PDF

A Case Study on the Characteristics of Cohousing (코하우징(Cohousing) 특성에 대한 사례조사 연구)

  • Jo, In-Sook;Shin, Hwa-Kyung;Lee, Jae-Joon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.159-164
    • /
    • 2003
  • Cohousing is communities balance the traditional advantages of home ownership with the benefits of shared common facilities and ongoing connections with your neighbors. It is characterized by private dwellings with their own kitchen living-dining room etc, but also extensive common facilities. These cooperative neighborhoods are one of the most promising solutions to many of today's most challenging social and environmental concerns. The purpose of this study is suggest planning direction to cohousing as alternative house. It focuses on the planning method through case study. The result of the study are summarized as follow ; Size of cohousing is 20${\sim}$50 family. Location of cohousing is urban. Type of house is detached house+row house. Size per family is 0${\sim}$15m$^2$. Common house makes up kitchen, dining-room living-room, guest room nursery room and so on.

  • PDF

Engine room cooling system using jet pump (제트 펌프를 이용한 엔진 룸 냉각 시스템)

  • Lim, Jeong-Woo;Lee, Sang-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.162-167
    • /
    • 2000
  • Construction machinery includes an engine enclosure separated from a cooling system enclosure by a wall to reduce noise and advance cooling system performance. For this structure, however, the axial fan cannot be of benefit to the engine room, and so the temperature rise in the engine room makes several bad conditions. This paper proposes that hot air in engine room is evacuated tv secondary pipe using jet pump. This paper demonstrates the structure and the effect of jet pump and useful guideline on design of area, length, and shape of secondary pipe to maximize the effect of jet pump.

  • PDF

The comparison and analysis of facilities factor of rolling stock interior design (철도차량 실내디자인 공간요소 비교분석)

  • Lee Jun-One
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.449-454
    • /
    • 2004
  • As social and cultural value has been changed, customers are demanding equipment innovation of passenger quarters to improve the satisfaction of their needs and the level of transfortation culture. To promote the convenience of passenger and abstract the facilities factor of passenger quarters design, this article analyzed and compared with the facilities factor of passenger quarters which have been operated in domestic and foreign country. While domestic passenger quarters is composed of seat, toilet and washroom, foreign passengers quarters consist of various factor such as familly room, infant room, business room, conversation room, and multipurpose room. Especially, foreign passenger quarters have provided passenger with diversity of attachment space, securing movement line for weak person, and arranging infant/child's space.

  • PDF

An Experimental Study on the Acoustic Characteristic of Korean Traditional Houses in Chonnam Province (전남 지방 전통주택의 음향특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.686-689
    • /
    • 2005
  • This study aims to analyzed the acoustics characteristics of Korean Traditional Houses in Chonnam Province varied with lay out and floor plane to reflect the way of control for environmental condition. These houses are surveyed the reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen. As a result, the reverberation time of traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building.

  • PDF

Evaluation on Acoustic Performance of the DICT's Acoustic Loboratory (대우건설기술연구소 음향실험동의 성능 평가)

  • 정갑철;이주원;윤창연;박칠림
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.735-740
    • /
    • 1998
  • Acoustic performance of DICT's acoustic laboratory was evaluated. As a result, background noise and inverse squre law of an anechoic room were satisfied with ISO 3745 standard value. Also, reverberation time and standard deviation of sound pressure level distribution in reverberation rooms were within maximum error limit that was ruled on ISO 3741.

  • PDF

Design and Implementation of Trusted Chatting Room Using Software TPM (소프트웨어 TPM 을 사용한 신뢰형 채팅룸 설계 및 구현)

  • Kennedy, Chinyere Grace;Cho, Dong-Sub
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.259-261
    • /
    • 2012
  • Chatting room has become widely using technology and it is vulnerable to the internet attackers. We proposed a chatting system using a Purebasic programming language to communicate across networks system. Chatting room text is a form of instant messaging between two or group of people. A Communication experiment was designed and implemented to confirm the validity of the developed chatting system on a trusted platform.

  • PDF