• 제목/요약/키워드: Cone-plate

검색결과 181건 처리시간 0.023초

매립지반의 팽이말뚝 평판재하시험 사례 연구 (Case Study Top-Base Foundation Static Loading Test in Reclaimed Land)

  • 신은철;김성환;이애영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.721-728
    • /
    • 2008
  • Top-Base Method is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and the effect of restraining settlement when the bearing capacity of the ground is not enough. Top-shaped cone concrete foundations are installed in graveled laid over soft ground. The principle of the basic method is to maximize effect of dispersing the overburden pressure by increasing the contact area of the top-shaped cone. Therefore, the bearing capacity is increased and the settlement is decreased by the embedded resistance of pile part in the ground. In this paper, the plate bearing test was conducted to evaluate the feasibility of Top-Base foundation. Based on the test results, the coefficient of subgrade reaction, elastic modulus, and settlement of foundation on reclaimed land was derived.

  • PDF

Poly(vinyl alcohol) hydrogel의 비 뉴톤 유변학적인 성질 (Non-Newtonian Rheological Properties of Poly(vinyl alcohol) hydrogel)

  • 김남정
    • Elastomers and Composites
    • /
    • 제44권3호
    • /
    • pp.323-328
    • /
    • 2009
  • 고분자 용융 같은 물질의 유변학적인 성질은 전단 흐름에서 복잡한 비 뉴톤 유동 현상을 보인다. 이들 유동성질은 유동단위와 유동부분 사이의 상호작용의 특성에 의하여 결정된다. poly(vinyl alcohol) hydrogel의 비 뉴톤유동 곡선을 cone-plate 레오메타로 여러 온도와 여러 농도 조건에서 얻었다. PVA hydrogel의 유동 곡선을 비 뉴톤 유동식에 적용시켜 유동 파라메타를 얻었다. 유동현상은 전단 속도가 증가함에 따라 전단박화의 틱소트로피 현상을 나타내었다.

플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구 (Risk of Smoke Occurring in the Combustion of Plastics)

  • 유지선;정영진
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.69-75
    • /
    • 2019
  • 본 연구에서는 5종의 섬유강화플라스틱(Fiber Reinforced Plastic, FRP), 폴리스티렌(Polystylene, PS), 폴리카보네이트(Polycarbonate, PC), 폴리프로필렌(Polypropylene, PP), 폴리염화비닐(Polyvinyl chloride, PVC) 판을 콘칼로리미터(Cone calorimeter, ISO 5660)를 이용하여 연소성을 시험하였다. 그 결과 PVC판은 최대열방출률($HRR_{peak}$)이 $44.65kW/m^2$, 최대평균열방사율(MARHE)이 $30.97kW/m^2$로 가장 낮게 나타났고, PS판은 $HRR_{peak}$$773.44kW/m^2$, MARHE는 $399.14kW/m^2$으로 가장 높게 나타났다. 일산화탄소의 평균($CO_{mean}$) 발생량은 PC판과 PS판이 최대 3.88배로 가장 많이 발생하였고, 반대로 이산화탄소($CO_{2mean}$)의 평균 발생량은 PS판과 PP판이 최대 4.88배로 가장 많이 발생하였다. 또 PS판은 다른 플라스틱보다 연기성능지수(SPI)가 74.81%~95.99% 감소하였고, 연기성장지수(SGI)는 76%~300%, 연기강도(SI)는 917.73%~9607.57% 증가하여 연기위험성이 높다는 것을 알 수 있었다. 따라서 PS판은 열적 측면에서나 연기 측면 모두 연기로 인한 인명피해의 위험성이 가장 높았음을 알았다.

Investigation of the Three-Dimensional Turbulent Flow Fields of the Gas Swirl Burner with a Cone Type Baffle Plate(I)

  • Kim, Jang-kweon
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.895-905
    • /
    • 2001
  • This paper presents vector fields, three dimensional mean velocities, turbulent intensities, turbulent kinetic energy and Reynolds shear stresses measured in the X-Y plane of the gas swirl burner with a cone type baffle plate by using an X-type hot-wire probe. This experiment is carried out at the flow rates of 350 and 450ℓ/min which are equivalent to the combustion air flow rate necessary to release 15,000 kcal/hr in a gas furnace. The results show that the maximum axial mean velocity component exists around the narrow slits situated radially on the edge of a burner. Therefore, there is some entrainment of ambient air in the outer region of a burner. The maximum values of turbulent intensities occur around the narrow slits and in front of a burner up to X/R=1.5. Moreover, the turbulent intensity components show a relatively large value in the inner region due to the flow diffusion and mixing processes between the inclined baffle plate and the swirl vane. Consequently, the combustion reaction is expected to occur actively near these regions.

  • PDF

난방기용 콘형 가스버너에서 3차원 난류 유동장 고찰 - 난류특성치에 대하여 - (Investigation of the Three-dimensional Turbulent Flow Fields in Cone Type Gas Burner for Furnace - On the Turbulent Characteristics -)

  • 김장권;정규조;김석우;김인규
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.21-26
    • /
    • 2001
  • This paper represents the turbulent intensity, the turbulent kinetic energy and Reynolds shear stress in the X-Y plane of cone type swirl gas burner measured by using X-probe from the hot-wire anemometer system. The experiment is carried out at flowrate 350 and $450{\ell}/min$ respectively in the test section of subsonic wind tunnel. The turbulent intensity and the turbulent kinetic energy show that the maximum value is formed in the narrow slits distributed radially on the edge of a cone type swirl burner, hence, the combustion reaction is anticipated to occur actively near this region. And the turbulent intensities ${\upsilon}\;and\;{\omega}$ are disappeared faster than the turbulent intensity u due to the inclined flow velocity ejecting from the swirl vanes of a cone type baffle plate of burner. Moreover, the Reynolds shear stress $u{\upsilon}$ is distributed about three times as large as the Reynolds shear stress $u{\omega}$ in the outer region of the cone type gas burner.

  • PDF

계장화한 긴 바를 사용한 세라믹판의 충격 파괴 거동 (Impact Fracture Behavior of Ceramic Plates Using Instrumented Long Bar)

  • 신형섭;오상엽;최수용;서창민;장순남
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.787-793
    • /
    • 2002
  • In this study, a bar impact test of low velocity was carried out to gain an insight into the damage mechanism and sequence induced in alumina plates(AD 85 and AD 90) under impact conditions. An experimental setup utilizing an instrumented long bar impact was devised, that can measure directly the impact force applied to the specimen and supply a compressive contact pressure to the specimen. During the bar impact testing, the influences of the contact pressure applied along the impact direction to the specimen on the fracture behavior were investigated. The measured impact force profiles explained well the damage behavior induced in alumina plates. The higher contact pressure to the specimen led to the less damage due to the suppression of radial cracks due to the increase in the apparent flexural stiffness of plate. It had produced the change of damage pattern developed in the specimen; from the radial cracks to the local contact stress dominant damage. It would contribute to the improvement of the ballistic property in ceramic plates. The observed results showed the following sequence in damage developed: The development of cone crack at impact region, the formation of radial cracks from the rear surface of plate depending on the plate thickness, the occurrence of crushing within the cone envelope and the fragmentation.

The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey

  • Safi, Yaser;Amid, Reza;Zadbin, Fariba;Ahsaie, Mitra Ghazizadeh;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.251-260
    • /
    • 2021
  • Purpose: Dental implants are widely used for the rehabilitation of edentulous sites. This study investigated the occurrence of dental implant malpositioning as shown on post-implantation cone-beam computed tomography (CBCT) and to identify related factors. Materials and Methods: Samples with at least 1 malpositioned dental implant were collected from a central radiology clinic in Tehran, Iran from January 2017 to January 2019. Variables such as demographic characteristics, length and diameter of implants, type of implant, sites of implant insertion, different types of implant malpositioning problems (cortical plate perforation, interference with anatomical structures), angulation of the implant, and the severity of malpositioning were assessed. In addition, the incidence of implant fracture and over-drilling was evaluated. Data were statistically analyzed using the chi-square test, 1-sample t-test, and Spearman correlation coefficients. Results: In total, 252 patients referred for implant postoperative CBCT evaluations were assessed. The cases of implant malpositioning included perforation of the buccal cortical plate (19.4%), perforation of the lingual cortical plate (14.3%), implant proximity to an adjacent implant (19.0%), implant proximity to an adjacent tooth (3.2%), interference with anatomical structures(maxillary sinus: 18.3%, mandibular canal: 11.1%, nasal cavity: 6.3%, mental foramen: 5.6%, and incisive canal: 0.4%). Implant fracture and over-drilling were found in 1.6% and 0.8% of cases, respectively. Severity was categorized as mild (9.5%), moderate (35.7%), severe (37.7%), and extreme (17.1%), and 52.4% of implants had inappropriate angulation. Conclusion: CBCT imaging is recommended for detecting dental implant malpositioning. The most common and severe type of malpositioning was buccal cortex perforation.

원위치 관입실험기를 활용한 철도 노반 평가 (Railbed Evaluation by using In-situ Penetration Test)

  • 김주한;박정희;윤형구;고태훈;이종섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능 (Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System)

  • 오창원
    • 한국건축시공학회지
    • /
    • 제18권5호
    • /
    • pp.463-469
    • /
    • 2018
  • 기존의 다층으로 구성되어 시공성이 낮은 옥상녹화 공법의 개선을 위해 개발한 방수 방근 시트 일체화 옥상녹화박스 유닛공법의 일체화를 위해 사용하는 전자기 유도가열방식의 금속 고정구와 콘 형상 고정구의 부착성능을 평가하기 위해 엔지니어링 PE, TPO, PVC 시트 등 3종류의 시트에 가열온도에 따른 부착성능 및 동일한 시험체로 냉열반복 후 부착성능을 측정하였다, 그 결과는 엔지니어링 PE시트에 부착한 고정구의 부착성능이 가장 우수하게 나타났으며, 금속고정구는 가열온도가 올라갈수록, 콘 형상 고정구는 가열온도가 낮을수록 우수한 부착성능을 보여주었고, 냉열 반복 후 부착시험 결과는 상온 부착시험 결과와 동일하게 나타났다. 기존의 양면 부틸테이프 고정방식의 콘 형상 고정구는 낮은 부착하중과 냉열반복에 의한 뚜렷한 성능저하가 발생하는데 비하여 전자기 유도가열방식의 고정구는 우수한 성능을 유지하였다.

Anthropometric analysis of maxillary anterior buccal bone of Korean adults using cone-beam CT

  • Lee, Seung-Lok;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권3호
    • /
    • pp.92-96
    • /
    • 2010
  • PURPOSE. The aim of this study was to evaluate the thickness of buccal and palatal alveolar bone and buccal bony curvature below root apex in maxillary anterior teeth of Korean adults using Cone-beam CT images. MATERIALS AND METHODS. The 3D image was reconstructed with dicom file obtained through CBCT from 20 - 39 year old Korean subjects (n = 20). The thickness of buccal and palatal plate, root diameter, the buccal bony curvature angle below root apex and the distance from root apex to the deepest point of buccal bony curvature were measured on maxillary anterior teeth area using OnDemand3D program. RESULTS. Mean thickness of buccal plate 3 mm below CEJ was $0.68{\pm}0.29\;mm$ at central incisor, $0.76{\pm}0.59\;mm$ at lateral incisor, and $1.07{\pm}0.80\;mm$ at canine. Mean thickness of palatal plate 3 mm below CEJ was $1.53{\pm}0.55\;mm$ of central incisor, $1.18{\pm}0.66\;mm$ of lateral incisor, $1.42{\pm}0.77\;mm$ of canine. Bucco-lingual diameter 3 mm below CEJ was $5.13{\pm}0.37\;mm$ of central incisor, $4.58{\pm}0.46\;mm$ of lateral incisor, and $5.93{\pm}0.47\;mm$ of canine. Buccal bony curvature angle below root apex was $134.7{\pm}17.5^{\circ}$ at central incisor, $151.0{\pm}13.9^{\circ}$ at lateral incisor, $153.0{\pm}9.5^{\circ}$ at canine. Distance between root apex and the deepest point of buccal bony curvature of central incisor was $3.67{\pm}1.28\;mm$ at central incisor, $3.90{\pm}1.51\;mm$ at lateral incisor, and $5.13{\pm}1.70\;mm$ at canine. CONCLUSION. Within the limitation of this study in Korean adults, the thickness of maxillary anterior buccal plate was very thin within 1mm and the thickness of palatal plate was thick, relatively. The buccal bony curvature below root apex of maxillary central incisor was higher than that of lateral incisor and canine and it seems that the buccal bony plate below root apex of central incisor is most curved.